Search results for " chimney"

showing 7 items of 17 documents

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique

2013

Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…

Settore MED/22 - Chirurgia Vascolareendovascular repair abdominal aorta pararenal aorta aneurysm endovascular aneurysm repair stent-graft chimney graft chimney technique deployment technique self-expanding stent-graft
researchProduct

Etude numérique du comportement thermique d’un séchoir solaire utilisant un lit thermique pour le stockage d’énergie

2018

This thesis presents a numerical study of an indirect natural convection solar dryer for drying agricultural products (Figs). The first part analyzes a solar dryer containing a drying chamber coupled to a reversed absorber and a solar chimney. Simulations were made to determine the dynamic and thermal fields under the influence of the variation of the solar chimney configuration and the size of the inlet opening. The governing equations based on the standard k-ε turbulence model are solved by the finite volume method using the ANSYS-Fluent commercial code. The second part analyzes the effect of adding a thermal storage in the form of a gravel bed in the drying chamber. The bed is modeled as…

[SPI.OTHER]Engineering Sciences [physics]/Other[SPI.OTHER] Engineering Sciences [physics]/OtherNatural convectionPacked bedConvection naturelleCheminée solaireÉcoulement turbulentSolar chimneyCfdLit en gravierTurbulent flow
researchProduct

Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…

2013

Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…

aortic aneurysm pararenal aortic aneurysm thoracoabdominal aortic aneurysm aortic arch endovascular aneurysm repair renal artery superficial mesenteric artery celiac trunk target vessel stent-graft side branch chimney graft periscope graft parallel graft target vessel patency endoleak side branch occlusionSettore MED/22 - Chirurgia Vascolare
researchProduct

IF01. Collected Worldwide Experience From the PERICLES Registry With the Use of Chimney Grafts in the Treatment of Type I Endoleaks After Previous En…

2017

medicine.medical_specialtyPERICLESbusiness.industrymedicine.medical_treatmentPERICLES; chimney; endoleakendoleakSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairSurgeryMedicineSurgeryChimneyRadiologyCardiology and Cardiovascular MedicinebusinesschimneyJournal of Vascular Surgery
researchProduct

Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry

2017

Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …

medicine.medical_specialtyRadiology Nuclear Medicine and Imagingabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graftendoleak610 Medicine & health030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineabdominal aortic aneurysmchimney techniqueNuclear Medicine and Imagingmedicine2741 Radiology Nuclear Medicine and ImagingChimney030212 general & internal medicinestent-graftbusiness.industryChimney graftchimney graftendograftmedicine.diseaseAbdominal aortic aneurysmSurgery10020 Clinic for Cardiac Surgery2746 SurgerygraftSurgerystentRadiologybusinessCardiology and Cardiovascular Medicineabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graft; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
researchProduct

RS12. Sustained Late Branch Patency and Low Incidence of Persistent Type Ia Endoleaks Following Snorkel/chimney EVAR Shown in the Updated PERICLES Re…

2016

medicine.medical_specialtybusiness.industryIncidence (epidemiology)030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareSurgery03 medical and health sciences0302 clinical medicineEndoleak; snorkel; chimney; PERICLEMedicineSurgeryChimney030212 general & internal medicineCardiology and Cardiovascular Medicinebusiness
researchProduct