Search results for " concentration"

showing 10 items of 1684 documents

A pH-tunable nanofluidic diode: electrochemical rectification in a reconstituted single ion channel.

2006

We report pH-dependent electrochemical rectification in a protein ion channel (the bacterial porin OmpF) reconstituted on a planar phospholipid membrane. The measurements performed at single-channel level show that the electric current is controlled by the protein fixed charge and it can be tuned by adjusting the local pH. Under highly asymmetric pH conditions, the channel behaves like a liquid diode. Unlike other nanofluidic devices that display also asymmetric conductance, here the microscopic charge distribution of the system can be explored by using the available high-resolution (2.4 A) channel crystallographic structure. Continuum electrostatics calculations confirm the hypothesized bi…

ChemistryStatic ElectricityAnalytical chemistryConductanceCharge densityPorinsHydrogen-Ion ConcentrationCrystallography X-RayIon ChannelsSurfaces Coatings and FilmsMembraneRectificationBacterial ProteinsBiomimeticsStatic electricityMaterials ChemistryElectrochemistryNanotechnologyPhysical and Theoretical ChemistryElectric currentIon channelDiodeThe journal of physical chemistry. B
researchProduct

Recent advances in on-line solid-phase pre-concentration for inductively-coupled plasma techniques for determination of mineral elements

2012

Abstract We provide a critical survey on recent progress in on-line solid-phase pre-concentration for inductively-coupled plasma (ICP)-based techniques for trace-level determination of metals. We highlight some of the useful solid-phase materials suitable for on-line separation and enrichment prior to ICP determination. We discuss different applications of the methods developed along with their analytical figures of merit. Finally, we sketch out future prospects in this field.

Chemistrybusiness.industryPhase (matter)Analytical chemistryCritical surveyFigure of meritInductively coupled plasmaPre concentrationProcess engineeringbusinessSpectroscopyAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

An overview of the analytical methods for the determination of organic ultraviolet filters in biological fluids and tissues.

2012

Organic UV filters are chemical compounds added to cosmetic sunscreen products in order to protect users from UV solar radiation. The need of broad-spectrum protection to avoid the deleterious effects of solar radiation has triggered a trend in the cosmetic market of including these compounds not only in those exclusively designed for sun protection but also in all types of cosmetic products. Different studies have shown that organic UV filters can be absorbed through the skin after topical application, further metabolized in the body and eventually excreted or bioaccumulated. These percutaneous absorption processes may result in various adverse health effects, such as genotoxicity caused b…

Chemistrymedicine.disease_causeBiochemistryAnalytical ChemistryBody FluidsMatrix (chemical analysis)Adverse health effectEnvironmental chemistryPercutaneous absorptionmedicineBiological fluidsEnvironmental ChemistryAnimalsHumansSample preparationTissue DistributionOrganic ChemicalsSpectroscopyGenotoxicityUltravioletVolume concentrationAnalytica chimica acta
researchProduct

Organic matter quantity and quality, metals availability and foraminiferal assemblages as environmental proxy applied to the Bizerte Lagoon (Tunisia)

2016

International audience; This study analyzes the benthic trophic state of Bizerte Lagoon (Tunisia) based on the total organic matter and the bioavailability of biopolymeric carbon including proteins (PTN), carbohydrates (CHO), lipids (LIP), chlorophyll a, as well as bacteria counts. The overall simultaneously extracted metals (SEM), and acid volatile sulfides (AVS) as well as the SEM/AVS ratio indicative of the toxicity of the sediments also were analyzed aiming to study their impact in the dimension, composition and structure of both dead and living benthic foraminiferal assemblages.In the studied sites TOC content is relatively high and the PTN/CHO values indicate that they can be consider…

Chlorophyll0106 biological sciencesMediterranean climateGeologic SedimentsChlorophyll aTunisiaChlorophyll aForaminiferaEnvironmentSulfides010501 environmental sciencesAquatic ScienceOceanography01 natural sciences[ SDE ] Environmental SciencesForaminiferaBiopolymer concentrationschemistry.chemical_compoundAcid volatile sulfidesSeawaterOrganic matter14. Life underwaterTOC0105 earth and related environmental sciencesTrophic levelchemistry.chemical_classificationBacteriabiologyEcology010604 marine biology & hydrobiologySedimentSimultaneously extracted metalsbiology.organism_classificationAcid volatile sulfides; Bacteria; Biopolymer concentrations; Chlorophyll a; Living benthic foraminifera; Oxygen isotopes; Simultaneously extracted metals; TOCPollution6. Clean waterLiving benthic foraminiferaCassidulinachemistryMetals13. Climate actionBenthic zoneEnvironmental chemistryOxygen isotopes[SDE]Environmental SciencesWater Pollutants ChemicalEnvironmental MonitoringMarine Pollution Bulletin
researchProduct

The negatively charged amino acids in the lumenal loop influence the pigment binding and conformation of the major light-harvesting chlorophyll a/b c…

2008

AbstractThe major chlorophyll (Chl) a/b complexes of photosystem II (LHCIIb), in addition to their primary light-harvesting function, play key roles in the organization of the granal ultrastructure of the thylakoid membranes and in various regulatory processes. These functions depend on the structural stability and flexibility of the complexes. The lumenal side of LHCIIb is exposed to broadly variable pH environments, due to the build-up and decay of the pH gradient during photosynthesis. Therefore, the negatively charged amino acids in the lumenal loop might be of paramount importance for adjusting the structure and functions of LHCIIb. In order to clarify the structural roles of these res…

ChlorophyllCircular dichroismPhotosystem IIPigment bindingMolecular ConformationBiophysicsPhotosynthesisBiochemistryMajor light-harvesting a/b complex of photosystem IILow pHAmino AcidsSpectroscopyPhotosystemchemistry.chemical_classificationChemistryCircular DichroismPhotosystem II Protein ComplexPigments BiologicalCell BiologyHydrogen-Ion ConcentrationAmino acidCrystallographyB vitaminsMutagenesisThylakoidBiophysicsElectrophoresis Polyacrylamide GelProtein BindingBiochimica et Biophysica Acta (BBA) - Bioenergetics
researchProduct

Water-Soluble Chlorophyll Protein (WSCP) Stably Binds Two or Four Chlorophylls

2017

Water-soluble chlorophyll proteins (WSCPs) of class IIa from Brassicaceae form tetrameric complexes containing one chlorophyll (Chl) per apoprotein but no carotenoids. The complexes are remarkably stable toward dissociation and protein denaturation even at 100 °C and extreme pH values, and the Chls are partially protected against photooxidation. There are several hypotheses that explain the biological role of WSCPs, one of them proposing that they function as a scavenger of Chls set free upon plant senescence or pathogen attack. The biochemical properties of WSCP described in this paper are consistent with the protein acting as an efficient and flexible Chl scavenger. At limiting Chl concen…

ChlorophyllModels Molecular0106 biological sciences0301 basic medicineProtein DenaturationHot TemperatureLightLight-Harvesting Protein ComplexesGene ExpressionThylakoids01 natural sciencesBiochemistryProtein Structure SecondaryDissociation (chemistry)law.inventionchemistry.chemical_compoundlawpolycyclic compoundsDenaturation (biochemistry)CarotenoidPlant Proteinschemistry.chemical_classificationSinglet OxygenProtein Stabilityfood and beveragesHydrogen-Ion ConcentrationBiochemistryRecombinant DNAOxidation-ReductionProtein BindingRecombinant Fusion ProteinsBrassicamacromolecular substancesBiology03 medical and health sciencesProtein DomainsTetramerPlant senescenceChlorophyll APeasWaterOxygen030104 developmental biologyWater solubleSolubilitychemistryChlorophyllProtein MultimerizationApoproteins010606 plant biology & botanyBiochemistry
researchProduct

Partial vinylphenol reductase purification and characterization from Brettanomyces bruxellensis

2008

International audience; Brettanomyces is the major microbial cause for wine spoilage worldwide and causes significant economic losses. The reasons are the production of ethylphenols that lead to an unpleasant taint described as 'phenolic odour'. Despite its economic importance, Brettanomyces has remained poorly studied at the metabolic level. The origin of the ethylphenol results from the conversion of vinylphenols in ethylphenol by Brettanomyces hydroxycinnamate decarboxylase. However, no information is available on the vinylphenol reductase responsible for the conversion of vinylphenols in ethylphenols. In this study, a vinylphenol reductase was partially purified from Brettanomyces bruxe…

Chromatography GasBrettanomycesMolecular Sequence DataVINYLPHENOL REDUCTASEBrettanomyces bruxellensisWineReductaseMicrobiology[ CHIM ] Chemical SciencesFungal Proteins03 medical and health sciencesHydrolysisOpen Reading FramesPhenolsOxidoreductaseGenetics[CHIM]Chemical SciencesAmino Acid SequenceMolecular Biology030304 developmental biologychemistry.chemical_classificationWineVOLATILE PHENOL0303 health sciencesbiology030306 microbiologyChemistryGuaiacolTemperatureBRETTANOMYCESHydrogen-Ion Concentrationbiology.organism_classificationNADAmino acidMolecular WeightKineticsEnzymeBiochemistryDETERIORATION MICROBIENNESaccharomycetalesBRUTTANOMYCES BRUXELLENSISFood MicrobiologyElectrophoresis Polyacrylamide GelOxidoreductases
researchProduct

Finding the best separation in situations of extremely low chromatographic resolution.

2010

Abstract Samples with a large number of compounds or similarities in their structure and polarity may yield insufficient chromatographic resolution. In such cases, however, finding conditions where the largest number of compounds appears sufficiently resolved can be still worthwhile. A strategy is here reported that optimises the resolution level of chromatograms in cases where conventional global criteria, such as the worst resolved peak pair or the product of elementary resolutions, are not able to detect any separation, even when most peaks are baseline resolved. The strategy applies a function based on the number of “well resolved” peaks, which are those that exceed a given threshold of…

Chromatography Reverse-PhaseChromatographyAcetonitrilesResolution (mass spectrometry)ChemistryLow resolutionOrganic ChemistrySeparation (aeronautics)Analytical chemistryGeneral MedicineFunction (mathematics)Partial resolutionHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryChromatographic separationModels ChemicalYield (chemistry)Organic ChemicalsJournal of chromatography. A
researchProduct

Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples

2014

In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins i…

Chromatography Reverse-PhaseChromatographyChemistryElutionChemical polarityAdrenergic beta-AntagonistsOrganic ChemistryAnalytical chemistryGeneral MedicineBiochemistryAnalytical ChemistrySurface-Active Agentschemistry.chemical_compound1-PropanolColumn chromatographyPulmonary surfactantMicellar liquid chromatographyCritical micelle concentrationSolventsHumansIndicators and ReagentsAnalytical proceduresMicellesSoftwareJournal of Chromatography A
researchProduct

1-Hexyl-3-methyl imidazolium tetrafluoroborate: an efficient column enhancer for the separation of basic drugs by reversed-phase liquid chromatograph…

2012

Abstract Ionic liquids are dual modifiers composed by a large anion and a large cation, which interact with both the hydrophobic alkyl-bonded phase and the anionic residual silanols in C18 columns. The deactivation of the silanol groups has important implications on the chromatographic analysis of basic drugs, being the improvement of peak profiles and shorter retention times the most noticeable features. However, other characteristics as selectivity or resolution are not usually considered, or are only examined for selected chromatographic conditions. In this work, the effect of the addition of the ionic liquid 1-hexyl-3-methyl imidazolium tetrafluoroborate to acetonitrile–water mixtures i…

Chromatography Reverse-PhaseChromatographyResolution (mass spectrometry)ChemistryOrganic ChemistryImidazolesGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryIonchemistry.chemical_compoundSilanolPharmaceutical PreparationsPhase (matter)Ionic liquidBoratesSelectivityAcetonitrileJournal of chromatography. A
researchProduct