Search results for " cornea"

showing 8 items of 98 documents

Biometric characterization of the anterior segment in a Sahrawi pediatric population

2013

Purpose: To examine the biometric characteristics of the anterior segment in a group of Sahrawi children. Methods: A total of 66 children (33 male and 33 female, aged between 8 and 13 years) participated in this prospective, observational study. The non-invasive Pentacam Scheimpflug imaging device was used to measure corneal thickness (CT) (at the thinnest corneal point), mean anterior (Km Ant) and posterior (Km Post) corneal radii, corneal volume (CVol), anterior chamber depth (ACD) and anterior chamber volume (ACVol). The contribution of age and gender to the various parameters was investigated. Results: CT values of the present group of Sahrawi children were 521.70 ± 3.92 m. Boys had thi…

medicine.medical_specialtyScheimpflug principlePediatric ocular biometryAge and genderlcsh:OphthalmologyOphthalmologylcsh:QC350-467MedicineGlaucoma preventionmedicine.diagnostic_testbusiness.industryPrevención de glaucomaScheimpflug imagingCorneal topographyCorneal thicknesslcsh:RE1-994Biometría ocular pediátricaGrosor cornealTopografía cornealOriginal ArticleCorneal topographysense organsImagen Scheimpflugbusinesslcsh:Optics. LightOptometryPediatric population
researchProduct

Clinical and genetic update of corneal dystrophies.

2019

The International Committee for Classification of Corneal Dystrophies (IC3D) distinguishes between 22 distinct forms of corneal dystrophy which are predominantly autosomal dominant, although autosomal recessive and X-chromosomal dominant patterns do exist. Before any genetic examination, there should be documentation of a detailed corneal exam of as many affected and unaffected family members as possible, because detailed phenotypic description is essential for accurate diagnosis. Corneal documentation should be performed in direct and indirect illumination at the slit lamp with the pharmacologically dilated pupil. For the majority of the corneal dystrophies, a phenotype-genotype correlatio…

medicine.medical_specialtygenetic structuresGenetic ExaminationCorneal dystrophyCollagen Type ITransforming Growth Factor beta1Cellular and Molecular NeuroscienceCorneaOphthalmologyGenotypemedicineHumansGenetic Predisposition to DiseaseCorneal Dystrophies Hereditarybusiness.industryEpithelium Cornealmedicine.diseasePhenotypeeye diseasesSensory SystemsCollagen Type I alpha 1 ChainOphthalmologyEpithelial recurrent erosion dystrophymedicine.anatomical_structuresense organsDifferential diagnosisbusinessTGFBIExperimental eye research
researchProduct

Interstitial Pregnancy: A 'Road Map' of Surgical Treatment Based on a Systematic Review of the Literature.

2014

An electronic search concerning the surgical approach in cases of interstitial pregnancy from January 2000 to May 2013 has been carried out. Fifty three studies have been retrieved and included for statistical analysis. Conservative and radical surgical treatments in 354 cases of interstitial pregnancy are extensively described. Hemostatic techniques have been reported as well as clinical criteria for the medical approach. Surgical outcome in conservative versus radical treatment were similar. When hemostatic techniques were used, lower blood losses and lower operative times were recorded. Conversion to laparotomy involved difficulties in hemostasis and the presence of persistent or multipl…

medicine.medical_specialtymedicine.medical_treatmentCornual PregnancyObstetric Surgical ProceduresInterstitial PregnancyPregnancyLaparotomymedicineHumansSurgical treatmentPregnancyEctopic pregnancyObstetricsbusiness.industryHemostasis EndoscopicAngular pregnancy corneal pregnancy ectopic pregnancy interstitial pregnancyObstetrics and Gynecologymedicine.diseaseAngular PregnancyHemostasis SurgicalSurgeryPregnancy InterstitialReproductive MedicineHemostasisInterstitial pregnancyFemaleLaparoscopybusiness
researchProduct

Corneal opacity and copper levels of the Lewis syndrome after systemic chemotherapy

2020

Abstract Purpose To report a female patient of biclonal Lewis syndrome which consists of a trias: biclonal gammopathy of undetermined significance, paraproteinemic keratopathy in form of a brownish discoid opacification at the level of Descemet's membrane and hypercupremia. After several years there was a conversion to multiple myeloma. Systemic chemotherapy led to a complete remission of multiple myeloma and to a normalization of the copper level in the blood that lasted five years. The corneal opacification remained unchanged. Observations A currently 66-year-old woman suffered from biclonal Lewis syndrome. On both eyes there is a central discoid yellow-brownish discoloration in the Pre-D…

medicine.medical_specialtymedicine.medical_treatmentUnchanged corneal opacity after chemotherapyGastroenterology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyChemotherapy-induced normal level of copper in serumInternal medicineMedicineAffinity of IgG to copper in Lewis syndromeCopper levelsProgressive anemiaMultiple myelomaLewis syndromeHypercupremiaChemotherapyBiclonal gammopathybusiness.industrySystemic chemotherapyHypercupremiaCorneal opacitymedicine.diseaseOphthalmologylcsh:RE1-994030221 ophthalmology & optometrybusinessDiscoid brownish opacification of Descemet membrane030217 neurology & neurosurgeryAmerican Journal of Ophthalmology Case Reports
researchProduct

Método de cálculo de la potencia de la lente intraocular pseudofáquica en pacientes intervenidos previamente de cirugía refractiva corneal láser

2018

Antecedentes: El valor de la potencia de la lente intraocular (PLIO) que sustituirá al cristalino en una cirugía de cataratas o lensectomía refractiva, es una función de la longitud axial (LA), la posición efectiva de la lente (PEL) y la potencia corneal (PC). Estas variables se introducen en una fórmula que proporciona el valor preciso de la PLIO para alcanzar el resultado refractivo programado. En ojos sin cirugías corneales previas, el resultado refractivo tras el implante es el esperado, con pequeños errores no significativos clínicamente. Sin embargo, cuando se calcula la PLIO en pacientes intervenidos previamente de cirugía refractiva corneal láser (CRCL), el resultado no es tan preci…

posición efectiva de la lente:FÍSICA::Óptica ::Optometría [UNESCO]cálculo de lentes intraocularescirugía refractiva lásercirugía de cristalinopotencia cornealUNESCO::FÍSICA::Óptica ::Optometría
researchProduct

Prevalence of dry eye disease in elderly individuals of the French population (the MONTRACHET Study)

2013

Purpose To report the prevalence of dry eye in a large population-based sample of French individuals older than 75 years. Methods About 9000 individuals 65 years and older were included in the 3C cohort study since 1999 in 3 French cities (Bordeaux, Dijon and Montpellier). In Dijon, an additional ophthalmic examination was performed 10 years after the initial inclusions to assess the relation between systemic age-related diseases and eye diseases in the MONTRACHET Study (Maculopathy Optic Nerve nuTRition neurovAsCular and HEarT diseases). Dry eye symptoms were collected with self reported history of dry eye symptoms, use of topical medications and evaluated by the Ocular Surface Disease Ind…

retinaétude épidémiologique[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologyœil486 cornea: tears/tear film/dry eyedroughtclinical studyeye diseases[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathology[ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory Organs463 clinical (human) or epidemiologic studies: prevalence/incidenceincidenceétude clinique[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organs[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologysécheresse
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct

Trehalose/hydroxyethylcellulose ocular gelling microspheres.

2008

trehalose microspheres norfloxacin reconstituted human corneal epithelium
researchProduct