Search results for " couple"

showing 10 items of 374 documents

Gel Electrophoresis Coupled to Inductively Coupled Plasma−Mass Spectrometry Using Species-Specific Isotope Dilution for Iodide and Iodate Determinati…

2007

In this paper, we present an online coupling of gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of iodine species (iodide and iodate) in liquid (seawater) and aerosol samples. For the first time, this approach is applied to the analysis of small molecules, and initial systematic investigations revealed that the migration behavior as well as the detection sensitivity strongly depends on the matrix (e.g., high concentrations of chloride). These effects could consequently affect the accuracy of analytical results, so that they need to be considered for the analysis of real samples. The technique used for quantification is species-specifi…

AerosolsElectrophoresis Agar Gelchemistry.chemical_classificationTime FactorsIodideIodatesAnalytical chemistrychemistry.chemical_elementIodidesIsotope dilutionIodineMass spectrometrySensitivity and SpecificityMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundIsotopesSpecies SpecificitychemistrySample preparationTriiodideInductively coupled plasma mass spectrometryIodateAnalytical Chemistry
researchProduct

High Pressure Processing Impact on Alternariol and Aflatoxins of Grape Juice and Fruit Juice-Milk Based Beverages.

2021

High-pressure processing (HPP) has emerged over the last 2 decades as a good alternative to traditional thermal treatment for food safety and shelf-life extension, supplying foods with similar characteristics to those of fresh products. Currently, HPP has also been proposed as a useful tool to reduce food contaminants, such as pesticides and mycotoxins. The aim of the present study is to explore the effect of HPP technology at 600 MPa during 5 min at room temperature on alternariol (AOH) and aflatoxin B1 (AFB1) mycotoxins reduction in different juice models. The effect of HPP has also been compared with a thermal treatment performed at 90 °C during 21 s. For this, different juice models, or…

AflatoxinFood industryFood HandlingLiquid Phase MicroextractionAlternariolPharmaceutical ScienceOrganic chemistryFood Contamination01 natural sciencesArticlealternariolAnalytical ChemistryPascalizationBeverageschemistry.chemical_compoundLactones0404 agricultural biotechnologyQD241-441AflatoxinsTandem Mass Spectrometryjuice modelsDrug Discoverydispersive liquid–liquid microextractionAnimalsVitisFood sciencePhysical and Theoretical ChemistryMycotoxinChromatography High Pressure LiquidOrange juicehigh-pressure processingbusiness.industry010401 analytical chemistry04 agricultural and veterinary sciencesMycotoxinsFood safety040401 food science0104 chemical sciencesFruit and Vegetable JuicesMilkchemistryChemistry (miscellaneous)Fruitaflatoxin B1Molecular Medicinebusinessliquid chromatography coupled to tandem mass spectrometryFood contaminantMolecules (Basel, Switzerland)
researchProduct

Multiplicity results for a class of asymmetric weakly coupled systems of second order ordinary differential equations

2005

We prove the existence and multiplicity of solutions to a two-point boundary value problem associated to a weakly coupled system of asymmetric second-order equations. Applying a classical change of variables, we transform the initial problem into an equivalent problem whose solutions can be characterized by their nodal properties. The proof is developed in the framework of the shooting methods and it is based on some estimates on the rotation numbers associated to each component of the solutions to the equivalent system.

Algebra and Number TheoryMathematical analysislcsh:QA299.6-433lcsh:AnalysisExponential integratorStochastic partial differential equationLinear differential equationCollocation methodOrdinary differential equationmultiplicity result asymmetric weakly coupled system nodal solutions rotation numberBoundary value problemAnalysisMathematicsSeparable partial differential equationNumerical partial differential equations
researchProduct

Non-chromatographic speciation

2010

We evaluate the main strategies for screening trace-element species in most types of sample to establish their strengths and weaknesses, as they offer fast, sensitive and cheaper alternatives to classical methods involving chromatography. We consider the principles of non-chromatographic speciation analysis, based on the different behaviors of chemical species before measurement by atomic and molecular spectrometry and electroanalytical methods, so as to give an update on the literature in this field of research.

Alternative methodsChemical speciesChromatographyChemistryGenetic algorithmElectroanalytical methodAtomic spectroscopyMolecular spectroscopyInductively coupled plasma mass spectrometrySpectroscopyAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

Electromechanical Numerical Analysis of an Air-Core Pulsed Alternator via Equivalent Network Formulation

2017

In this paper, the numerical analysis on an air-core pulsed alternator is presented. Since compulsators are characterized by very fast electromechanical transients, their accurate analysis requires strong coupling between the equations governing the electrical and the mechanical behaviors. The device is investigated by using a dedicated numerical code capable to take into account eddy currents, compensating windings, as well as the excitation/control circuits. Furthermore, the code is capable of modeling centrifugal forces and vibrations acting on the shaft due to electric and mechanical unbalances or to misalignments of the shaft from its centered position. This makes the code a very power…

Alternator (automotive)Nuclear and High Energy PhysicsAir-core machine020209 energyMechanical engineeringCompensated pulsed alternator02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici01 natural sciencescoupled analysiseddy current010305 fluids & plasmaslaw.inventionintegral formulationlawPosition (vector)0103 physical sciences0202 electrical engineering electronic engineering information engineeringEddy currentcompulsatorNuclear and High Energy PhysicElectronic circuitPhysicsnumerical modelsAir-core machine; compulsator; coupled analysis; eddy currents; integral formulation; numerical modelsbusiness.industryNumerical analysisElectrical engineeringeddy currentsCondensed Matter PhysicsVibrationcoupled analysiElectromagnetic coilnumerical modelbusiness
researchProduct

Determination of antimony, arsenic, bismuth and copper by inductively coupled plasma atomic emission spectrometry in the electrorefining of copper

1996

Inductively coupled plasma atomic emissionspectrometry (ICP-AES) has been applied as a rapid and routine method for the analysis of process electrolytes in the electrorefining of copper. Antimony, arsenic, bismuth and copper have been selected as major electrolyte constituents. For these elements profound statistical studies of spectral and interelement effects have been carried out. For As, Bi and Sb two analyte wavelengths have been selected, and for Cu one relatively insensitive analyte line has been chosen due to the high Cu concentration in samples. Best analytical lines were: As at 193.759 nm, Bi at 306.772 nm, Sb at 206.833 nm and Cu at 216.953 nm. Multiple linear regression proved t…

AnalyteAntimonyChemistryAnalytical chemistrychemistry.chemical_elementElectrolyteInductively coupled plasmaBiochemistryCopperArsenicAnalytical ChemistryElectrowinningBismuthAnalytical and Bioanalytical Chemistry
researchProduct

The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…

2009

Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…

AnalyteChromatographyAcoustics and UltrasonicsOrganic ChemistryAnalytical chemistrychemistry.chemical_elementZincInorganic Chemistrychemistry.chemical_compoundChromiumDigestion (alchemy)chemistryFly ashChemical Engineering (miscellaneous)Environmental ChemistryAqua regiaRadiology Nuclear Medicine and imagingInductively coupled plasmaMicrowave digestionUltrasonics sonochemistry
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

AnalyteChromatographyChemistryAnalytical chemistrychemistry.chemical_elementPlasmaAnalytical ChemistryMatrix (chemical analysis)Fly ashStandard additionLinear regressionInductively coupled plasmaSpectroscopyArsenicJournal of Analytical Atomic Spectrometry
researchProduct

First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas

2014

The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…

AnalyteHydrogenAnalytical chemistrychemistry.chemical_elementOxygenAnalytical ChemistryTriple quadrupole mass spectrometerIonAmmoniachemistry.chemical_compoundchemistryIsobaric processInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct