Search results for " dental"

showing 10 items of 516 documents

Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

2016

Background: The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods: A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and…

Dental Restoration FailurePeri-implantitismedicine.medical_treatmentAlveolar Bone LossMEDLINEDentistryHIV InfectionsOdontologíaComplications (Medicine)Malalties de la boca03 medical and health sciences0302 clinical medicineMucositismedicineHumansDental Restoration Failure030212 general & internal medicineGeneral DentistryRetrospective StudiesDental ImplantsRehabilitationImplants dentalsbusiness.industryResearchDental implantsRetrospective cohort study030206 dentistry:CIENCIAS MÉDICAS [UNESCO]medicine.diseasePeri-ImplantitisCiencias de la saludTreatment OutcomeComplicacions (Medicina)Mouth diseasesOtorhinolaryngologySpainUNESCO::CIENCIAS MÉDICASSurgeryImplantOral SurgeryHIV-positive personsbusinessPersones seropositivesViral loadFollow-Up Studies
researchProduct

Medication-related osteonecrosis of the jaw associated with implant and regenerative treatments : systematic review

2019

Background The aim of this study was to determine if the treatment with bisphosphonates other anti-resorptive and antiangiogenic agents influences the success of regenerative and / or implant treatments. Material and Methods We reviewed the literature from the last 5 years in the PubMed database, using the following words: “Sinus Floor Augmentation”[Mesh] OR “Dental Implants”[Mesh]) OR “Guided Tissue Regeneration”[Mesh]) AND “Osteonecrosis”[Mesh]. The articles were selected following the inclusion and exclusion criteria and were evaluated using the 22 items of the STROBE declaration. The following PICO clinical question was applied: Does the treatment with agents associated with drug osteon…

Dental Restoration FailureSinus Floor AugmentationBone RegenerationDatabases FactualMEDLINESinus Floor AugmentationDentistryReviewRessenyes sistemàtiques (Investigació mèdica)law.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawSystematic reviews (Medical research)medicineOssosAnimalsHumansDental Restoration FailureMethodological qualityGeneral DentistryDental ImplantsBonesDiphosphonatesImplants dentalsbusiness.industryDental Implantation EndosseousDental implantsOsteonecrosisAntibodies Monoclonal030206 dentistryMedically compromised patients in Dentistrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyEfectes secundaris dels medicamentsInclusion and exclusion criteriaUNESCO::CIENCIAS MÉDICASDrug side effectsSurgeryImplantbusinessOsteonecrosis of the jawDrug Antagonism
researchProduct

Endosseous dental implant fractures an analysis of 21 cases

2008

Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths ? while only two fractured implants were supporting overdentures instead…

Dental RestorationDental prosthesisRestauració dentalUNESCO::CIENCIAS MÉDICASImplants dentals intraossis:CIENCIAS MÉDICAS [UNESCO]Pròtesis dentalsFracturesEndosseous dental implants
researchProduct

In vitro comparison of the retention capacity of new aesthetic brackets.

1999

Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not require the use of a primer. The non-silanated ceramic bracket produced the lowest bond strength (8.88 N). Bond failures occurred mainly between bracket and cement, although a small percentage occurred between the enamel-cement interface with the metal and plastic brackets and within the cement for the …

Dental Stress AnalysisCeramicsMaterials scienceOrthodontic BracketsSurface PropertiesDentistryOrthodonticsEsthetics DentalAcid Etching DentalAdhesivesTensile StrengthUltimate tensile strengthAluminum OxideAnimalsOrthodontic Appliance DesignBisphenol A-Glycidyl MethacrylateCeramicComposite materialDental EnamelCementAnalysis of VariancePolycarboxylate CementEnamel paintbusiness.industryBond strengthBrackettechnology industry and agricultureDental BondingStainless SteelSubstrate (building)visual_artvisual_art.visual_art_mediumCattleEquipment FailureAdhesiveStress MechanicalbusinessEuropean journal of orthodontics
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection

2020

The bioengineering and medical and biomedical fields are ever closer, and they manage to obtain surprising results for the development of new devices. The field of simulations and studies in silica has undergone considerable development in recent years, favoring the advancement of medicine. In this manuscript, a study was carried out to evaluate the force distribution on the implant components (In-Kone® Universal) and on the peri-implant tissues subjected to loading. With the finite element analysis and the Von Mises method, it was possible to evaluate this distribution of forces both at 0 degrees (occlusal force) and at 30 degrees; the applied force was 800 N. The obtained results on this …

Dental Stress AnalysisField (physics)Article SubjectComputer sciencemedicine.medical_treatmentFinite Element AnalysisBiomedical EngineeringGeneral Biochemistry Genetics and Molecular BiologyBone and BonesBite ForceStress (mechanics)03 medical and health sciences0302 clinical medicinemedicinevon Mises yield criterionHumansDental implantDental ImplantsGeneral Immunology and Microbiologybusiness.industryR030206 dentistryGeneral MedicineConical surfaceStructural engineeringFinite element methodConnection (mathematics)MedicineDevelopment (differential geometry)Stress Mechanicalbusiness030217 neurology & neurosurgeryFinite Element Method Von Mises Investigation Bone Response Conical Dental Implant ConnectionResearch Article
researchProduct

Influence of prefabricated post dimensions on restored maxillary central incisors

2007

summary  The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …

Dental Stress AnalysisMaterials sciencebusiness.industryFinite Element AnalysisGlass fiberDentistryModels TheoreticalStress distributionStainless SteelModels DentalIncisorDental MaterialsDental Prosthesis DesignFlexural strengthMaterials TestingHumansComputer SimulationMaxillary central incisorDental Restoration FailureGlassFinite element techniquebusinessGeneral DentistryPost and Core TechniqueJournal of Oral Rehabilitation
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct

Choice of ceramic for use in treatments with porcelain laminate veneers.

2006

El tratamiento mediante Frentes Laminados de Porcelana (FLP) se utiliza desde hace más de dos décadas para el tratamiento de problemas estéticos y/o funcionales, particularmente en el grupo anterior de las arcadas dentarias (1,2,3). La actual oferta en el mercado de cerámicas dentales aptas para este tipo de tratamiento, pero muy distintas en cuanto a composición, características ópticas y sistema de elaboración, hace complicada la selección del material más adecuado a cada paciente en particular. Proponemos un sistema sencillo de elección de la cerámica teniendo en cuenta las dos variables que más influirán en el resultado estético final: de un lado las características propias del diente (…

Dental ceramicsporcelain laminate veneersclasificación porcelanaUNESCO::CIENCIAS MÉDICASfrentes laminadosporcelain classificationesthetic:CIENCIAS MÉDICAS [UNESCO]Cerámica dentalestética
researchProduct