Search results for " dose"
showing 10 items of 593 documents
Dose-finding study of oxaliplatin associated to capecitabinebased preoperative chemoradiotherapy in locally advanced rectal cancer
2018
// Gemma Bruera 1, 2 , Mario Di Staso 3 , Pierluigi Bonfili 3 , Antonio Galvano 4 , Rosa Manetta 5 , Gino Coletti 6 , Roberto Vicentini 7 , Stefano Guadagni 2, 8 , Corrado Ficorella 2, 9 , Ernesto Di Cesare 2, 3 , Antonio Russo 4 and Enrico Ricevuto 1, 2 1 Oncology Territorial Care, S. Salvatore Hospital, Oncology Network ASL1 Abruzzo, University of L'Aquila, L'Aquila, Italy 2 Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, L’Aquila, Italy 3 Radiotherapy, S. Salvatore Hospital, Oncology Network ASL1 Abruzzo, University of L’Aquila, L’Aquila, Italy 4 Medical Oncology, Department of Surgical, Oncological and Stomatological Sciences, University of Palermo,…
Technical development in cardiac CT: current standards and future improvements—a narrative review
2020
Non-invasive depiction of coronary arteries has been a great challenge for imaging specialists since the introduction of computed tomography (CT). Technological development together with improvements in spatial, temporal, and contrast resolution, progressively allowed implementation of the current clinical role of the CT assessment of coronary arteries. Several technological evolutions including hardware and software solutions of CT scanners have been developed to improve spatial and temporal resolution. The main challenges of cardiac computed tomography (CCT) are currently plaque characterization, functional assessment of stenosis and radiation dose reduction. In this review, we will discu…
Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources
2008
The two most commonly used modalities of cancer treatment in clinical brachytherapy practice today are high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy. In a clinical treatment, quality dose rate distribution data sets of the brachytherapy sources are required for each source model. The purpose of this study is to obtain detailed dose rate distributions around the new BEBIG HDR and PDR Ir-192 brachytherapy sources. These distributions will then be used as input data in the treatment planning systems dedicated to brachytherapy and its calculations can be verified. The Monte Carlo method was used to obtain the dose rate distributions around the sources studied, taking into accoun…
Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radio…
2012
"\"La tomografia computerizzata del cuore (CCT) è diventata uno strumento efficace in differenti contesti clinici. Lo sviluppo della tecnologia ha portato ad una progressiva espansione delle indicazioni con una concomitante riduzione della dose di radiazioni necessaria per l’esecuzione dell’indagine. Ancora oggi sono pochi i documenti delle maggiori società scientifiche internazionali che si esprimono sulle effettive modalità di utilizzo e sulle indicazioni cliniche della CCT; in particolare mancano delle linee guida complete. Questo documento rispecchia la visione del gruppo di lavoro della Sezione di Cardio-Radiologia della Società Italiana di Radiologia Medica in merito alle indicazioni …
Breath test using 13C methacetin does not seem to be useful in the assessment of liver function in girls with anorexia nervosa: a case control study
2018
Abstract Background Anorexia nervosa (AN) concerns approximately up to 1.8% of the pediatric female population. One of the complications that can occur in the course of this disease is acute liver failure. This study’s objective was to assess the usefulness of the 13C labeled Methacetin Breath Test (MBT) in the diagnostics of the liver function in girls with eating disorders. Methods For the study 81 girls aged 12 to 17 years were recruited, including 41 patients with confirmed diagnosis of AN (mean age 14.7 ± 1.48 years) and 40 age-matched controls. The diagnosis was based on the present Diagnostic and Statistical Manual of Mental Disorders (DSM-5) criteria. Weight and height were measured…
Urethral Dose Limit in Boost Permanent Prostate 125I Seed Implants Based on Biologically Effective Dose Values
2010
Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography
2009
The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…
Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry
2016
Over the past years there has been an increase in the assessment of eye lens doses in interventional radiology procedures. This is due to the new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) that proposes to reduce equivalent dose limit for the eye lens. The aim of this study is to make estimates of equivalent dose received by eye lens of the medical staff in interventional neuroradiology procedures. Consequently, this study presents an alternative for eye lens dosimetry. For this purpose nanoDot dosimeters based on optically stimulated luminescence (OSL) technology from Landauer Inc. product were used. The measurements obtained for …
Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry
2016
The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.
Efficacy and Safety of IQYMUNE®, a Ten Percent Intravenous Immunoglobulin in Adult Patients With Chronic, Primary Immune Thrombocytopenia
2018
Background: Intravenous immunoglobulin (IVIG) IQYMUNE® is a highly purified 10% IVIG that was assessed using the new stringent definition of response described in the revised guideline on the clinical investigation of IVIG. The efficacy and the safety of IQYMUNE® were investigated in adult patients with chronic primary immune thrombocytopenia (ITP). Methods: In this phase III multinational, multicentre, prospective, uncontrolled, open-label, single-arm study, adult patients with a baseline platelet count < 30 × 10 9 /L were treated with IVIG 10% at a dose of 2 g/kg body weight administered over 2 consecutive days. The primary endpoint was Response over the study period and was defined accor…