Search results for " equipment."

showing 10 items of 314 documents

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Plaque removal efficacy of power and manual toothbrushes: a comparative study

2009

The aim of this study was to compare the plaque removal efficacy of a new oscillating/rotating/pulsating toothbrush [Oral-B® Professional Care® 8500 (PC 8500)] with two manual toothbrushes [Oral-B® CrossAction™ Vitalizer (CAV) and Oral-B® Indicator™ (IND), respectively]. The safety of the PC 8500 was also assessed. The study was a single-use, observer-masked, randomised 3×3 Latin square crossover design balanced for carryover effects. The enrolled subjects (n=66) refrained from brushing for 23–25 h before each clinical examination. Plaque scores were recorded before and after brushing with the allocated toothbrush using the Turesky et al. modification of the Quigley and Hein plaque index. T…

AdultMaleToothbrushingPlaque indexAdolescentPlaque removalPlaque removalDental PlaqueDentistryManual toothbrushPlaque controlStatistics Nonparametriclaw.inventionDental Devices Home CareRandomised crossover single-use studyPower toothbrushYoung AdultElectricitylawSettore MED/28 - Malattie OdontostomatologicheMedicineHumansSingle-Blind MethodManual toothbrushGeneral DentistryAnalysis of VarianceChi-Square DistributionCross-Over StudiesEquipment Safetybusiness.industryDental Plaque IndexMiddle AgedCrossover studyDental Plaque IndexSafety EquipmentPlaque indexFemaleToothbrushSafetybusiness
researchProduct

Efficacy of 3 toothbrush treatments on plaque removal in orthodontic patients assessed with digital plaque imaging: a randomized controlled trial.

2013

Good oral hygiene is a challenge for orthodontic patients because food readily becomes trapped around the brackets and under the archwires, and appliances are an obstruction to mechanical brushing. The purpose of this study was to compare plaque removal efficacy of 3 toothbrush treatments in orthodontic subjects.This was a replicate-use, single-brushing, 3-treatment, examiner-blind, randomized, 6-period crossover study with washout periods of approximately 24 hours between visits. Forty-six adolescent and young adult patients with fixed orthodontics from a university clinic in Germany were randomized, based on computer-generated randomization, to 1 of 3 treatments: (1) oscillating-rotating …

AdultMaleToothbrushingRandomizationAdolescentPlaque removalElectrical Equipment and SuppliesDental PlaqueDentistryOrthodonticsManual toothbrushlaw.inventionYoung AdultRandomized controlled trialOrthodontic ApplianceslawImage Processing Computer-AssistedMedicineHumansSingle-Blind MethodChildFluorescent DyesOrthodonticsCross-Over Studiesbusiness.industryBrushEquipment DesignCrossover studyTreatment OutcomePhotography DentalPlaque imagingFemaleFluoresceinToothbrushbusinessAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
researchProduct

Response of the aging eye to first day of modern material contact lens wear

2018

Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…

AdultMaleUlls Acomodació i refracciómedicine.medical_specialtyAgingPopulationBaseline levelCornea03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologymedicineHumansProspective StudiesFluoresceineducationDisposable EquipmentVision OcularOsmoleeducation.field_of_studyOsmotic concentrationbusiness.industryOsmolar ConcentrationEquipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicTear osmolarityeye diseasesÒptica Aparells i instrumentsContact lensOphthalmologyTear meniscuschemistryPatient SatisfactionTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsbusinessConjunctiva030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.

2015

To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…

AdultMaleVisual Acuitylaw.inventionCorneaYoung AdultlawMyopiaMedicineHumansDisposable EquipmentKeratometerCorneal curvaturebusiness.industryHealthy subjectsCorneal TopographyGeneral MedicineEquipment DesignContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyOptometryDaily disposableFemalesense organsThickeningbusinessOptometryFollow-Up StudiesContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Diurnal variations in visual performance for disposable contact lenses.

2013

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …

AdultMaleVisual acuitygenetic structuresmedia_common.quotation_subjectVisual AcuityContrast SensitivityYoung AdultmedicineMyopiaContrast (vision)HumansDisposable EquipmentVision Ocularmedia_commonMathematicsContact Lenses Hydrophiliceye diseasesCircadian RhythmOphthalmologyOptometryDaily disposableFemalesense organsDisposable Equipmentmedicine.symptomOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Effects of treadmill running and fatigue on impact acceleration in distance running

2014

The effects of treadmill running on impact acceleration were examined together with the interaction between running surface and runner's fatigue state. Twenty recreational runners (11 men and 9 women) ran overground and on a treadmill (at 4.0 m/s) before and after a fatigue protocol consisting of a 30-minute run at 85% of individual maximal aerobic speed. Impact accelerations were analysed using two lightweight capacitive uniaxial accelerometers. A two-way repeated-measure analysis of variance showed that, in the pre-fatigue condition, the treadmill running decreased head and tibial peak impact accelerations and impact rates (the rate of change of acceleration), but no significant differenc…

AdultMalemedicine.medical_specialtyAccelerationPhysical Therapy Sports Therapy and RehabilitationAccelerometerRunningSports EquipmentYoung AdultAccelerationTreadmill runningPhysical medicine and rehabilitationDistance runningAccelerometrymedicineHumansOrthopedics and Sports MedicineForeheadTreadmillMathematicsLegImpact accelerationSignificant differenceBiomechanical PhenomenaShock (mechanics)Muscle FatiguePhysical therapySports Biomechanics
researchProduct

Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2014

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

AdultMalemedicine.medical_specialtyAnterior ChamberScheimpflug principlePupil diameterIrisVergenceDiagnostic Techniques OphthalmologicalPupilAnterior chamber angleNear visionAnterior chamber eyeYoung AdultOpticslcsh:OphthalmologyOphthalmologyPhotographyMedicineHumansskin and connective tissue diseasesPupilaAnterior chamberCâmara anteriorTécnicas medidas equipamentos de mediçãobusiness.industryAccommodation OcularPupilGeneral Medicineeye diseasesOphthalmologyAcomodação ocularlcsh:RE1-994Accommodation ocularTechniques measures measurement equipmentFemalesense organsbusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.

2014

Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P0.05), medial midfoot (70 vs. 105 kPa, P0.01), and lateral midfoot (62 vs 96…

AdultMalemedicine.medical_specialtyContact timeRestSTRIDEPhysical Therapy Sports Therapy and RehabilitationRunningSports EquipmentPhysical medicine and rehabilitationPressureMedicineHumansOrthopedics and Sports MedicineFoot OrthosesFatiguebusiness.industryRunning injuriesFootEquipment DesignShoesGait analysisAthletic InjuriesFemaleStress MechanicalbusinessJournal of sports sciences
researchProduct