Search results for " extraction"
showing 10 items of 1344 documents
o-Phthalaldehyde–N-acetylcysteine polyamine derivatives: formation and stability in solution and in C18 supports
2001
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde-N-acetylcysteine (OPA-NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8 +/- 2 x 10(-2) min(-1) in solution versus 7.7 +/- 1.1 x 10(-4) min(-1) on the (C18) solid support. The results obtai…
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid…
2002
A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte pe…
Determination of aliphatic amines in water by liquid chromatography using solid-phase extraction cartridges for preconcentration and derivatization
2001
Bond Elut C18 solid-phase extraction cartridges were used for preconcentration and pre-column derivatization with 3,5-dinitrobenzoyl chloride (DNB) of aliphatic amines in water. Conditions for analyte preconcentration and derivatization (including the volume of sample, concentration of reagent, time of reaction and pH) were investigated, using ethylamine, isopropylamine and dimethylamine as model compounds. On the basis of these studies, a rapid and sensitive method for the determination of aliphatic amines in water is presented. The analytes are retained and purified on the cartridges and then derivatized and desorbed by drawing in succession the DNB solution and acetonitrile. The collecte…
Development of a Rapid Method for the Determination of Phenolic Antioxidants in Dark Chocolate Using Ultra Performance Liquid Chromatography Coupled …
2017
Development of a new comprehensive method based on one-step liquid-liquid extraction (LLE) combined with ultra-high-performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) for the determination of eight phenolic compounds in dark chocolate is demonstrated. The study focuses on the optimization of sample preparation, chromatographic separation and Orbitrap-HRMS detection parameters to adjust selectivity and sensitivity of the method. The LLE mixture of formic acid-water-acetonitrile (2:58:40, v/v) and hexane at the component ratio of 1:1 (v/v) was applied for sample preparation. The inter-day and intra-day precision expressed from the relative stand…
Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.
2017
A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…
Analytical strategies to determine quinolone residues in food and the environment
2007
23 páginas, 5 figuras, 5 tablas.
Development of a selective solid phase extraction method for nitro musk compounds in environmental waters using a molecularly imprinted sorbent
2013
A powerful analytical method for the determination of the family of the nitro musk compounds at trace level in environmental waters-river, sea, and water from a treatment plant-is presented. The method is based on the use of molecularly imprinted silica (MIS) as sorbent for solid phase extraction (SPE) used for the clean-up and the concentration step of the target analytes previous to their determination by gas chromatography-mass spectrometry. The optimized extraction procedure allowed extraction recoveries between 61% and 87% using the MIS. The comparison with a non-imprinted silica (NIS) sorbent, for which extraction recoveries between 8% and 26% were obtained, showed the high selectivit…
Immuno-SLM—a combined sample handling and analytical technique
2004
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …