Search results for " field test"

showing 8 items of 38 documents

Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry

2012

PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…

Malemedicine.medical_specialtygenetic structuresContact LensesOpticsCLs upper limitsPattern standard deviationOphthalmologymedicineHumansMathematicsCross-Over Studiesbusiness.industryAutomated perimetryPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractive lensCrossover studyeye diseasesVisual fieldAbsolute deviationOphthalmologySensory ThresholdsVisual Field TestsFemaleVisual FieldsbusinessAlgorithmsEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Prediction Accuracy of a Novel Dynamic Structure-Function Model for Glaucoma Progression

2014

Purpose To assess the prediction accuracy of a novel dynamic structure-function (DSF) model to monitor glaucoma progression. Methods Longitudinal data of paired rim area (RA) and mean sensitivity (MS) from 220 eyes with ocular hypertension or primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Rim area and MS were expressed as percent of mean normal based on an independent dataset of 91 healthy eyes. The DSF model uses centroids as estimates of the current state of the disease and velocity vectors as estimates of direction and rate of change over time. The first three visits were used to pre…

Malemedicine.medical_specialtygenetic structuresWilcoxon signed-rank testOptic DiskOptic diskOcular hypertensionGlaucomaCellular and Molecular NeurosciencePredictive Value of TestsOphthalmologyLinear regressionHumansMedicineLongitudinal StudiesAgedbusiness.industryLinear modelBayes TheoremArticlesMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyCase-Control StudiesPredictive value of testsOrdinary least squaresDisease ProgressionLinear ModelsVisual Field TestsFemaleOcular HypertensionVisual FieldsbusinessGlaucoma Open-AngleInvestigative Ophthalmology &amp; Visual Science
researchProduct

Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes

2015

Color perimetry has interesting clinical application for the diagnosis and detection of certain eye conditions, due to the variations that certain diseases can cause in chromatic thresholds, both in the red-green (RG) and the blue-yellow (BY) pathways.[1,2,3,4] The separate study of the visual function of both the chromatic and achromatic mechanisms could be more efficient in detecting sensitivity variations, and such variations would not be obscured by the intrusion of other mechanisms. Currently, the supply of conventional perimeters that are capable of performing a chromatic perimetry test is very limited and with reduced options regarding the possibility of choosing the physical charact…

Maleretinakoniohemangioblastomagenetic structuresComputer sciencemelanocytosisGlaucomaretinal vasoproliferative tumorEyeTwo stageslaw.inventionintra-arterial chemotherapyretinal capillary hemangiomaIntrusionlcsh:Ophthalmologylawperiocular chemotherapyintravitreal chemotherapytreatmentdiabetesenhanced depth imagingDiabetesenhanced depth imaging optical coherence tomographyMiddle AgedhemangiomaAchromatic lensFemaleOriginal Articleuveal melanomanevusAdulttumorchoroidal hemangiomaCiliary bodymonosomy 3lymphomaStimulus (physiology)Color spaceAutoflouroscenceuvearetinoblastomaContrast SensitivityosteomaCavernous hemangiomaParvoMagnoResearch basedmedicinemelanomagene expression profilingHumansmetastasisChemotherapyChromatic scalemetastasesirisÓpticachromatic perimetryoptical coherence tomographyintravenous chemotherapybusiness.industryChoroidKonioSubtenon′s chemotherapyReproducibility of ResultsPattern recognitionGlaucomamedicine.diseaseAchromatic perimetrymagnoOphthalmologyglaucomaDiabetes Mellitus Type 2lcsh:RE1-994parvoOptometryVisual Field TestsAstrocytic hamartomavitreous seedsArtificial intelligenceprognosisVisual FieldsbusinessChromatic perimetrymalignancy
researchProduct

High myopic patients with and without foveoschisis: morphological and functional characteristics.

2020

Purpose: Myopic foveoschisis (MF) is characterized by the splitting of the retinal layers in the fovea of patients with high myopia (HM). MF may progress into foveal detachment or macular hole formation with consequent loss of central vision. The aim of this study is to investigate morphological and functional changes of the macular region in myopic subjects with and without foveoschisis. Design: Observational, cross-sectional, comparative study. Methods: Forty-eight patients with HM and 24 healthy controls were evaluated by spectral domain-optical coherence tomography (SD-OCT), multifocal electroretinography (mfERG) and microperimetry (MP-1) tests to assess macular thickness, functionality…

Myopic foveoschisisMalemedicine.medical_specialtyFovea Centralisgenetic structuresRetinoschisisVisual AcuityRetinoschisisFoveoschisisRetina03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePhysiology (medical)OphthalmologyHigh myopiaVitrectomyPost-hoc analysismedicineChi-square testElectroretinographyHumansMacular holePathological myopiabusiness.industryMultifocal electroretinography (mfERG)RetinalMiddle Agedmedicine.diseaseRetinal Perforationseye diseasesSensory SystemsSpectral domain-optical coherence tomography (SD-OCT)high myopia; microperimetry (MP-1); multifocal electroretinography (mfERG); myopic foveoschisis; pathological myopia; retinoschisis; spectral domain-optical coherence tomography (SD-OCT)OphthalmologyCross-Sectional StudieschemistryMyopia Degenerative030221 ophthalmology & optometryMicroperimetry (MP-1)Visual Field TestsFemalesense organsAnalysis of varianceVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgeryTomography Optical CoherenceDocumenta ophthalmologica. Advances in ophthalmology
researchProduct

Hippocampal theta activity, learning and behavioral tendencies

2014

Trace eyeblink conditioning is a method that models a declarative, awareness-dependent form of learning. Hippocampal theta activity, an approximately 3.5 - 8.5 Hz oscillatory pattern in rabbits, has been associated with learning-related phenomena: arousal, attentional processes and association forming. In some studies theta-contingent training, given during a brain state rich in hippocampal theta oscillation, has improved the initial learning in trace eyeblink conditioning. However, other laboratories have failed to replicate this effect. This study explored the effects of theta-contingent conditioning and extinction on learning, and the connection between the magnitude of spontaneous hippo…

Open Field testoppiminenextinctioneducationtheta-contingent conditioninghippokampustheta activityHippocampustrace eyeblink conditioning
researchProduct

Effects of 8-OH-DPAT on open field performance of young and aged rats prenatally exposed to diazepam: a tool to rveal 5-HT1a receptor function

2003

Central GABAergic and serotoninergic systems interact with one another and are implicated in controlling different behaviours. A gentle early long-lasting handling can prevent the deficits in locomotion and exploration in open field (O.F.) in 3-month-old male rats prenatally exposed to diazepam (DZ). Purpose of this study was to extend the research to older handled rats prenatally exposed to DZ and to assess the activity of 5-HT1A receptors (Rs), evaluating the performance in O.F. at 3 and 18 months of age following 8-OH-DPAT administration. A single daily s.c. injection of DZ (1.5 mg/kg) from gestation day 14 to gestation day 20 induced in aged, but not in young rats, a decrease in total d…

Open field testAging8-OH-DPATLong-lasting handlingSettore BIO/14 - FarmacologiaRatPrenatal diazepam
researchProduct

Motor and cognitive development: the role of karate

2014

Background: regular physical activity has an effect on biological responses in both muscles and organs that, in turn, alter the structure and functions of the brain. Therefore, this study aims at comparing motor (sprint, coordination ability and explosive legs strength skills) and cognitive abilities (working memory, attention, executive functioning) in children. Methods: 39 children with average chronological age of 9 years were divided in: Karatekas (n=19) and Sedentary (n=20) groups. Their abilities were measured by motor and cognitive tests. Motor skills were assessed through a battery composed by the 20 mt Sprint test, the Agility test and the Standing board jump Test. Cognitive profil…

medicine.medical_specialtyWorking memoryMotor controlCognitionExecutive functionsDevelopmental psychologyCognitive testPhysical medicine and rehabilitationSprintchildre cognitive abilities motor abilities motor control field testMemory spanmedicineOriginal ArticleOrthopedics and Sports MedicinePsychologyMotor skillMuscles, Ligaments and Tendons Journal
researchProduct

Current Clinical Application of Microperimetry: A Review.

2018

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications. MP has been shown to be useful in the characterization of sensory and motor conditions, such as amblyopia or nystagmus. Concerning ocular pathology, several studies have confirmed the usefulness of MP for evaluating and analyzing different…

medicine.medical_specialtygenetic structuresOcular PathologyGlaucomaNystagmusFixation OcularAmblyopiaMicroperimetryOcular Motility Disorders03 medical and health scienceschemistry.chemical_compoundNystagmus0302 clinical medicineOcular Motility DisordersRetinal DiseasesFovealOphthalmologymedicineHumansRetinal sensitivityVisual rehabilitationÓpticabusiness.industryReproducibility of ResultsRetinalGeneral MedicineMacular degenerationmedicine.diseaseeye diseasesOphthalmologychemistryEye fixation030221 ophthalmology & optometryVisual Field Testsmedicine.symptomVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgerySeminars in ophthalmology
researchProduct