Search results for " fractures"
showing 10 items of 284 documents
The rodent tibia fracture model: A critical review and comparison with the complex regional pain syndrome literature
2018
Abstract Distal limb fracture is the most common cause of complex regional pain syndrome (CRPS), thus the rodent tibia fracture model (TFM) was developed to study CRPS pathogenesis. This comprehensive review summarizes the published TFM research and compares these experimental results with the CRPS literature. The TFM generated spontaneous and evoked pain behaviors, inflammatory symptoms (edema, warmth), and trophic changes (skin thickening, osteoporosis) resembling symptoms in early CRPS. Neuropeptides, inflammatory cytokines, and nerve growth factor (NGF) have been linked to pain behaviors, inflammation, and trophic changes in the TFM model and proliferating keratinocytes were identified …
Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.
2007
Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…
Transverse fracture-dislocation of the sacrum: a diagnostic pitfall and a surgical challenge.
2002
Transverse fracture-dislocations of the sacrum are rare. Associated lesions of the lumbosacral spine as well as neurological injuries are common. Conventional radiographs of the pelvis often fail to clearly visualize the fracture. Delayed diagnosis increases the risk of progressive neurological disfunction. True lateral sacral views and CT-scans with 3-dimensional reconstructions are very helpful in establishing the full extent of the injury. These examinations should be considered in all patients with a history of high energy trauma and clinical signs indicating lumbosacral injury, such as severe low back pain and neurological disturbances of the lower extremities. The management of transv…
The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
2013
Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…
Posterior perilunate carpal dislocation associated with a multifragmentary distal radius fracture.
2009
Summary Dorsal perilunate wrist dislocations are rare. Associated carpal bones or radial styloid process fractures can occur and be included in the current classifications. The authors report an unusual association of dorsal perilunate wrist dislocation with a multifragmentary distal radius fracture. Such traumatic entity has never been previously described. Poor functional outcome may justify the inclusion of associated complex forearm bone fractures in wrist dislocation classifications.
Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept
2020
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …
Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.
1989
With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…
Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis
2015
In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…
Reconstruction of vertebral body in thoracolumbar AO type A post-traumatic fractures by balloon kyphoplasty: a series of 85 patients with a long foll…
2019
Background Traumatic fractures of the thoracolumbar spine are common injuries, accounting for approximately 90% of all spinal traumas. Optimal management of these fractures still gives rises to much debate in the literature. Currently, one of the treatment options in young patients with stable traumatic vertebral fractures is conservative treatment using braces. Kyphoplasty as a minimally invasive procedure has been shown to be effective in stabilizing vertebral body fractures, resulting in immediate pain relief and improved physical function with early return to work activity. The aim of the study is to report VAS, ODI scores, and kyphosis correction following treatment. Methods This is a …