Search results for " frequency"
showing 10 items of 1398 documents
Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator
2012
A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.
Superresolved imaging based on wavelength multiplexing of projected unknown speckle patterns
2015
We propose a method for resolution enhancement of a diffraction limited optical system based on the capture of a set of low resolution images. These images are obtained after projection of an ensemble of unknown speckle patterns on top of the high resolution object that is to be imaged. Each speckle pattern is generated by the same thin (and unknown) diffuser, but illuminated with a slightly different wavelength. From the ensemble of low resolution images, we obtain a system of equations that can be solved in an iterative manner that enables reconstruction of the high resolution object. As a result, we also achieve the projected high resolution speckle patterns used for the encoding.
Enhancing spatial resolution in digital holographic microscopy by biprism structured illumination.
2014
A novel and efficient architecture of a structured-illumination digital holographic microscope (DHM) is presented. As the DHM operates at the diffraction limit, its spatial resolution on label-free imaging of transparent samples is improved by illuminating the sample with a structured illumination produced by a Fresnel's biprism. The theoretical analysis of the method forecasts a twofold improvement of the spatial resolution. The proposed method requires only two images to improve the spatial resolution, which eases the process of unmixing the high-resolution components by means of an unknown phase-shift procedure. Numerical modeling and experimental results validate the theoretical finding…
Merits of vision in presence of light scattering using Tiffen ProMist filters
2020
Light scattering caused by Tiffen ProMist photographic filters of various grades at different laser radiation 640 nm, 532 nm and 405 nm was objectively studied and compared. The lack of removal of speckles from the scene of laser radiation scattering did not allow an accurate assessment of the effect of scattering on the decrease in image contrast. Subjective deterioration in visual acuity using various contrast optotypes and contrast sensitivity was assessed by scattering induction using filters up to grade #5. Vision contrast sensitivity diminishes within all studied spatial frequency range 0.5-18 cpd. The degradation of the impact factor to visual acuity without scattering filters when t…
Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simula…
2012
Purpose. To compare optical and visual quality of the implantable Collamer lens (ICL) and laser in situ keratomileusis (LASIK) for myopia. Methods. An adaptive optics visual simulator (CRX1, Imagine Eyes, France) was used to simulate the vision after ICL implantation and LASIK procedure from the wavefront aberration pattern for -3 and -6 D. Monocular visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20, and 25 cycles/degree (cpd) were measured for 3- and 5-mm pupils. Modulation transfer function (MTF) and point spread function (PSF) were calculated for a 5-mm pupil. Results. The ICL showed a MTF near of diffraction-limited MTF, but the post-LASIK of MTF worsened…
Wavefront Recovery: Shack-Hartmann Aberrometry vs PhaseLift Using a Single Binary Amplitude Modulating Mask
2019
We investigate whether a wavefront can be recovered by using a single mask rotated in four different positions. Results show that PhaseLift can recover the wavefront from intensity measurements using such a kind of modulation.
Assessment of ventilatory thresholds from heart rate variability in five incremental treadmill tests in cross country skiers
2014
Incremental treadmill tests are widely used in the field of exercise physiology for the assessment of Ventilatory Thresholds for clinical and sport oriented issues. The assessment of Ventilatory Thresholds (VTs) from Heart Rate Variability (HRV) is a relatively new approach with increasing popularity because it is a non-invasive and economical method. Nevertheless, this has not been used in Cross Country (XC) Skiing, an endurance sport where the knowledge of VTs holds special importance. The purpose of the study was to assess VTs using the data derived from HRV analysis in the five main XC skiing-related techniques, Double Poling (DP), Diagonal Striding (DS), Nordic Walking (NW), V1 Skating…
A multi-centre study of candidate genes for wheeze and allergy: the International Study of Asthma and Allergies in Childhood Phase 2
2009
BACKGROUND: Common polymorphisms have been identified in genes suspected to play a role in asthma. We investigated their associations with wheeze and allergy in a case-control sample from Phase 2 of the International Study of Asthma and Allergies in Childhood. METHODS: We compared 1105 wheezing and 3137 non-wheezing children aged 8-12 years from 17 study centres in 13 countries. Genotyping of 55 candidate single nucleotide polymorphisms (SNPs) in 14 genes was performed using the Sequenom System. Logistic regression models were fitted separately for each centre and each SNP. A combined per allele odds ratio and measures of heterogeneity between centres were derived by random effects meta-ana…
Strategies and Techniques for Powering Wireless Sensor Nodes through Energy Harvesting and Wireless Power Transfer
2019
The continuous development of internet of things (IoT) infrastructure and applications is paving the way for advanced and innovative ideas and solutions, some of which are pushing the limits of state-of-the-art technology. The increasing demand for Wireless Sensor Nodes (WSNs) able to collect and transmit data through wireless communication channels, while often positioned in locations that are difficult to access, is driving research into innovative solutions involving energy harvesting (EH) and wireless power transfer (WPT) to eventually allow battery-free sensor nodes. Due to the pervasiveness of radio frequency (RF) energy, RF EH and WPT are key technologies with the potential to power …
The Fit for Delivery study: rationale for the recommendations and test-retest reliability of a dietary score measuring adherence to 10 specific recom…
2012
Aiming at preventing excessive weight gain during pregnancy, 10 specific dietary recommendations are given to pregnant women in the intervention arm of the Norwegian Fit for Delivery (FFD) study. This paper presents the rationale and test-retest reliability of the food frequency questionnaire (FFQ) and a dietary score measuring adherence to the recommendations. The study is part of the ongoing FFD study, a randomised, controlled, intervention study in nulliparous pregnant women. A 43-item FFQ was developed for the FFD study. A dietary score was constructed from 10 subscales corresponding to the 10 dietary recommendations. Adding the subscales yielded a score from 0 to 10 with increasing sco…