Search results for " gamma ray"

showing 10 items of 74 documents

On the importance of background subtraction in the analysis of coronal loops observed with TRACE

2010

In the framework of TRACE coronal observations, we compare the analysis and diagnostics of a loop after subtracting the background with two different and independent methods. The dataset includes sequences of images in the 171 A, 195 A filter bands of TRACE. One background subtraction method consists in taking as background values those obtained from interpolation between concentric strips around the analyzed loop. The other method is a pixel-to-pixel subtraction of the final image when the loop had completely faded out, already used by Reale & Ciaravella 2006. We compare the emission distributions along the loop obtained with the two methods and find that they are considerably differen…

PhysicsBackground subtractionTrace (linear algebra)Subtractionastrofisica Fisica solare Sun: corona Sun: X-rays gamma rays method: data analysisFOS: Physical sciencesAstronomy and AstrophysicsAstrophysicsSTRIPSCoronal loopFilter (signal processing)law.inventionComputational physicsLoop (topology)Settore FIS/05 - Astronomia E AstrofisicaAstrophysics - Solar and Stellar AstrophysicsSpace and Planetary SciencelawSolar and Stellar Astrophysics (astro-ph.SR)Interpolation
researchProduct

Analysis of a multi-wavelength time-resolved observation of a coronal loop

2005

Several items on the diagnostics and interpretation of coronal loop observations are under debate. In this work, we analyze a well-defined loop system detected in a time-resolved observation in several spectral bands. The dataset includes simultaneous images in the TRACE 171 A, 195 A and 284 A bands, and Yohkoh/SXT, and two rasters taken with SoHO/CDS in twelve relevant lines. The loop is initially best visible in the TRACE 195 A filter band, and later in the 171 A filter band, with correspondence with the CDS raster images at log T \~ 6.0-6.1. We have taken as pixel-by-pixel background the latest TRACE, Yohkoh and CDS images where the loop has faded out. We examine the loop morphology evol…

PhysicsBackground subtractionbusiness.industryAstrophysics (astro-ph)FOS: Physical sciencesAstronomy and AstrophysicsAstrophysicsSpectral bandsCoronal loopAstrophysicsLight curveSpectral lineRatio distributionLoop (topology)corona – Sun : X-rays gamma raysOpticsUV radiation – SunSpace and Planetary ScienceFilter (video)business
researchProduct

HINODE /EIS SPECTROSCOPIC VALIDATION OF VERY HOT PLASMA IMAGED WITH THE SOLAR DYNAMICS OBSERVATORY IN NON-FLARING ACTIVE REGION CORES

2012

We use coronal imaging observations with SDO/AIA, and Hinode/EIS spectral data, to explore the potential of narrow band EUV imaging data for diagnosing the presence of hot (T >~5MK) coronal plasma in active regions. We analyze observations of two active regions (AR 11281, AR 11289) with simultaneous AIA imaging, and EIS spectral data, including the CaXVII line (at 192.8A) which is one of the few lines in the EIS spectral bands sensitive to hot coronal plasma even outside flares. After careful coalignment of the imaging and spectral data, we compare the morphology in a 3 color image combining the 171, 335, and 94A AIA spectral bands, with the image obtained for CaXVII emission from the an…

PhysicsExtreme ultraviolet lithographyImaging spectrometerGamma rayFOS: Physical sciencesAstronomy and AstrophysicsAstrophysicsPlasmaSpectral bandsSpectral lineSettore FIS/05 - Astronomia E AstrofisicaAstrophysics - Solar and Stellar AstrophysicsSpace and Planetary ScienceTemporal resolutionSolar and Stellar Astrophysics (astro-ph.SR)Sun: activity Sun: corona Sun: UV radiation Sun: X-rays gamma rays techniques: imaging spectroscopyLine (formation)The Astrophysical Journal
researchProduct

Temperature Distribution of a Non-flaring Active Region from Simultaneous Hinode XRT and EIS Observations

2011

We analyze coordinated Hinode XRT and EIS observations of a non-flaring active region to investigate the thermal properties of coronal plasma taking advantage of the complementary diagnostics provided by the two instruments. In particular we want to explore the presence of hot plasma in non-flaring regions. Independent temperature analyses from the XRT multi-filter dataset, and the EIS spectra, including the instrument entire wavelength range, provide a cross-check of the different temperature diagnostics techniques applicable to broad-band and spectral data respectively, and insights into cross-calibration of the two instruments. The emission measure distribution, EM(T), we derive from the…

PhysicsImaging spectrometerGamma rayFOS: Physical sciencesAstronomy and AstrophysicsPlasmaAstrophysicsabundances Sun: activity Sun: corona Sun: UV radiation Sun: X-rays gamma rays techniques: spectroscopic [Sun]Sun: abundances Sun: activity Sun: corona Sun: UV radiation Sun: X-rays gamma rays techniques: spectroscopicSpectral linelaw.inventionTelescopeData setSettore FIS/05 - Astronomia E AstrofisicaAstrophysics - Solar and Stellar AstrophysicsSpace and Planetary SciencelawExtreme ultravioletThermalSolar and Stellar Astrophysics (astro-ph.SR)
researchProduct

Evidence of Widespread Hot Plasma in a Nonflaring Coronal Active Region from Hinode/X-Ray Telescope

2009

Nanoflares, short and intense heat pulses within spatially unresolved magnetic strands, are now considered a leading candidate to solve the coronal heating problem. However, the frequent occurrence of nanoflares requires that flare-hot plasma be present in the corona at all times. Its detection has proved elusive until now, in part because the intensities are predicted to be very faint. Here, we report on the analysis of an active region observed with five filters by Hinode/X-Ray Telescope (XRT) in 2006 November. We have used the filter ratio method to derive maps of temperature and emission measure (EM) both in soft and hard ratios. These maps are approximate in that the plasma is assumed …

PhysicsLine-of-sightMonte Carlo methodGamma rayAstronomy and AstrophysicsX-ray telescopePlasmaAstrophysicsIsothermal processNanoflareslaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaSpace and Planetary SciencelawSun: activity Sun: corona Sun: X-rays gamma rays
researchProduct

The Status of the ARGO Experiment at YBJ

2007

The ARGO-YBJ experiment, located at Yangbajing, Tibet, China, performed by a wide Sino-Italian collaboration, is designed to study cosmic rays, sub-TeV gamma ray sources and GeV Gamma Ray Burst (GRB) emission in the northern hemisphere, by means of detecting small size EAS (Extensive Air Shower) using a full coverage RPC (Resistive Plate Chamber) carpet. The central carpet of the detector is installed and put into operation to date, with 1900 m^2 of the carpet already operating since December 2004. With a trigger multiplicity of ≥60 hits, corresponding to a primary mode energy of 2 TeV, the angular resolution of EAS measurements is < 1 degree for showers with more than 500 recorded hits. We…

PhysicsNuclear and High Energy PhysicsCosmic rays gamma ray sources Gamma Ray Burst Extensive Air Shower Resistive Plate ChamberARGO-YBJAstrophysics::High Energy Astrophysical PhenomenaDetectorNorthern HemisphereGamma rayAstrophysics::Instrumentation and Methods for AstrophysicsResistive plate chamberCosmic rayAstrophysicsAstronomia gammaAtomic and Molecular Physics and OpticsSciami estesiRaggi cosmiciAir showerGamma-ray burstArgo
researchProduct

Time-dependent electric field in Al/CdTe/Pt detectors

2015

Abstract Al/CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopy, even though they suffer from bias-induced time instability (polarization). Polarization phenomena cause a progressive time-degradation of the spectroscopic performance of the detectors, due to hole trapping and detrapping from deep acceptor levels that directly control the electric field distribution. In this work we present experimental investigations on the electric field profile of planar Al/CdTe/Pt detectors by means of Pockels effect measurements. The time/temperature dependence of the electric field was investigated in a long time window (up to 10 h) and the correlation with the reverse c…

PhysicsNuclear and High Energy PhysicsDeep acceptor levelbusiness.industryTrappingAcceptorPockels effectCadmium telluride photovoltaicsCdTe detectorX-ray and gamma ray spectroscopyPlanarPolarizationElectric fieldElectric fieldOptoelectronicsAtomic physicsPolarization (electrochemistry)businessSpectroscopyPockels effectInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The ARGO-YBJ experiment in Tibet

2008

The setting up of the ARGO detector at the YangBaJing Cosmic Ray Laboratory (4300 m a.s.l., Tibet, P.R. China) has been completed during the last spring (2007). It consists of a central carpet made of 130 identical sub-units of 12 RPCs each (a "cluster"), covering a surface of about 5800 m2 with 93% active area, and a guard ring of 24 further clusters of the same type surrounding the central carpet with a lower sampling density. Signals are picked up by external electrodes of small size, thus allowing the sampling of EAS with high space-time granularity. Shower events are detected at a trigger rate of about 4 kHz. Events with a few particles detected by a single cluster are counted in scale…

PhysicsNuclear and High Energy PhysicsGamma ray burstSingle clusterTrigger rateDetectorgamma ray bursts gamma rays cosmic rays extended air showersAstronomySampling (statistics)Cosmic rayExtended air showers Cosmic rays Gamma ray sources Gamma ray burstsGamma ray sourcesGeodesyCosmic rayGuard ringExtended air showerSampling densityInstrumentationArgoNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Performance of the ALICE photon spectrometer PHOS

2003

Abstract We present in this paper the measured characteristics of a 64 lead–tungstate crystal array designed to detect high-energy photons and neutral mesons with the ALICE photon spectrometer PHOS. The array has been tested with electron and charged pion secondary beams delivered by the CERN PS and SPS synchrotrons. Photon energy and π 0 invariant mass resolutions are presented. The PHOS particle identification performance for data simulated with the AliRoot package is studied.

PhysicsNuclear and High Energy PhysicsPhotonLarge Hadron Collider25.75.Nq; 24.10.Lx; 25.75.-q; 29.40.VjMesonSpectrometerElectromagnetic calorimeters010308 nuclear & particles physicsPhysics::Instrumentation and DetectorsElectronPhoton energyHigh-energy gamma rays7. Clean energy01 natural sciencesParticle identificationQuark–gluon plasmaNuclear physicsPion0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]PWO scintillators010306 general physicsNuclear ExperimentInstrumentation
researchProduct

Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques

2011

Abstract The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound …

PhysicsNuclear and High Energy PhysicsSpectrometerPreamplifierbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleCompound semiconductors CdTe detectors X-ray and gamma ray spectroscopy Digital pulse processing Pulse height analysis Pulse shape analysisParticle detectorPulse (physics)OpticsGamma spectroscopySpectroscopybusinessInstrumentationShape analysis (digital geometry)
researchProduct