Search results for " generation."
showing 10 items of 1108 documents
Stable and long-time operation of a soft x-ray laser for user applications experiments
2011
LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.
Hydrophobic Encapsulated Phosphonium Salts-Synthesis of Weakly Coordinating Cations and their Application in Wittig Reactions
2015
Large and rigid tetraarylphosphonium tetrafluoroborate salts have been synthesized representing weakly coordinating cations with diameters of several nanometers. Divergent dendritic growth by means of thermal Diels-Alder cycloaddition was employed for the construction of the hydrophobic polyphenylene framework up to the third generation. X-ray crystal structure analysis of first-generation phosphonium tetrafluoroborate supported the rigidity of the non-collapsible shell around the phosphorus center and gave insight into solid-state packing and cation-anion distances. Copper(I)-catalyzed azide-alkyne ligation served as reliable method for the preparation of a first-generation triazolylphenyl…
A numerical meshless particle method in solving the magnetoencephalography forward problem
2012
In this paper, a numerical meshless particle method is presented in order to solve the magnetoencephalography forward problem for analyzing the complex activation patterns in the human brain. The forward problem is devoted to compute the scalp potential and magnetic field distribution generated by a set of current sources representing the neural activity, and in this paper, it has been approached by means of the smoothed particle hydrodynamics method suitably handled. The Poisson equation generated by the quasi-stationary Maxwell's curl equations, by assuming Neumann boundary conditions has been considered, and the current sources have been simulated by current dipoles. The adopted meshless…
Modifiche del codice RELAP5/MOD3.2.b per lo studio delle perdite di carico e dello scambio termico in condotti elicoidali interessati da deflussi bif…
2011
L’attività di ricerca svolta nell’ambito della linea progettuale LP2-B.2 del programma PAR 2008-09 (CERSE III) ha visto una prima fase in cui è stato ulteriormente sviluppato il lavoro svolto nel corso dei precedenti programmi CERSE [1, 2], riguardante la validazione del codice termoidraulico avanzato Relap5/Mod3.2.b, modificato per il calcolo delle cadute di pressione in tubi elicoidali interessati da deflussi monofase e bifase, ed una seconda fase che ha comportato l’implementazione di nuove procedure valide per lo studio dello scambio termico bifase in condotti elicoidali, in aggiunta a quelle relative al solo scambio termico monofase, in precedenza implementate. Per quanto riguarda ques…
Assessment of energy management technique for achieving the sustainable voltage level during grid outage of hydro generator interfaced DC Micro-Grid
2021
Abstract An appropriate energy management scheme is needed for the reliable and sustainable operation of DC microgrid. The energy management scheme of DC microgrid (MG) is mainly controlled by main energy resource of MG. Main energy resource needs to be dispatchable unit for forming the reference voltage within DC MG. In this work, a micro hydro generator (MHG) is considered as a dispatchable source for forming the sustainable voltage level of DC MG operating under the abnormal condition. In this work, the abnormality refers to the outage of solar PV due to intermittency during fluctuating load condition. But, due to mechanical time constant of MHG and rate of charging/discharging current l…
Performance assessment of institutional photovoltaic based energy system for operating as a micro-grid
2020
Abstract A building integrated photovoltaic (PV) system with energy storage within an institution may need appropriate coordination among distributed energy sources (DERs). It is required to have an appropriate energy management strategy to improve system performance as well as to operate it as a micro-grid during the grid outage condition. In this paper, TERI’s (India) Retreat Facility’s energy system has been used, and its performance with a distributed generator has been assessed with operational strategies for fulfilling the institutional load demand in coordination with the PV, grid and battery storage; and with possibility of operating it as a micro-grid during the grid outage period …
The influence of the stochastic features of the energy source on the design of an electromagnetic generator
2009
The purpose of this paper is to clarify in a general way how the unavoidable randomness of renewable energy sources influences the magnetic design of electric generator. A general model of electro magnetic generator based on the well known d-q axes analysis is given. The energy source is modelled as a stochastic variable and is included in the equations of the system. The equations are solved and, therefore, the energy output of the system is linked to the random characteristic of the energy source. As a result, the magnetic circuit and the parameters of the generator that maximize the energy extraction can be found and generally linked to the stochastic details of the source.
Grid interaction and environmental impact of a net zero energy building
2020
Abstract The concept of Net Zero Energy Building (NZEB), as a grid-connected building that generates as much energy as it uses over a given period, has been developing through policies and research agendas during the last decade as a contribution towards the decarbonization of the building sector. However, since the most applicable and widely used renewable energy supply options are non-programmable, the large-scale NZEBs diffusion into the existing power grids can seriously affect their stability having a relapse on operation costs and environmental impacts. In this context, the study aims at performing the design of the energy systems to be used in the case-study through a wide numbers of…
Evaluation of the optimal renewable electricity mix for Lampedusa island: The adoption of a technical and economical methodology
2020
Abstract Worldwide, the majority of small islands not connected to the main grid is still dependent on fossil fuels. From an economic and environmental point of view, this condition is no more sustainable given the high costs for electricity generation and the high level of pollutant emissions. Furthermore, the dependence on fossil fuel represents a risk for the security of the supply of several small developing Countries since they are obliged to import those resources from foreign Countries. The introduction of renewable energy sources in small islands represents a valid solution to solve these problems. In this context, the paper investigates the case of Lampedusa, a small Italian island…
Towards an integrated design of renewable electricity generation and storage systems for NZEB use: A parametric analysis
2021
Abstract Although nearly zero energy buildings have attracted growing research attention, literature analysis shows that only a limited number of researches try to couple load match/grid interaction issues and environmental impacts in early design stages. The study proposes a novel multidisciplinary design approach that allows to integrate these two conflicting aspects aiming to find trade-offs. The proposed approach has been applied to a building case study, equipped with a photovoltaics system without energy storage. The results show that even though on yearly basis the energy use (5,290 kWhe) is largely overcome by the on-site energy generation (8069 kWhe), an oversized PV system alone m…