Search results for " hernia"
showing 10 items of 194 documents
Dynamic inguinal hernia repair with a 3d fixation-free and motion-compliant implant: a clinical study.
2014
Static solutions for highly motile structures such as the groin seem to represent a procedural incongruence. Another important issue in prosthetic hernia repair is related to the poor quality of tissue ingrowth within conventional flat meshes and plugs. These are all static, passive devices, and thus do not move in synchrony with the natural movements of the groin. In the literature there is a clear understanding of how conventional prostheses used for inguinal hernia repair are incorporated by rigid fibrotic tissue. The term "scar plate" well emphasizes this occurrence. The ingrowth of this kind of stiff fibrotic scar leads to mesh shrinkage and to the reduction of the mesh surface area. T…
USE OF INTRAPERITONEAL PTFE DUAL-MESH IN A GIANT INCISIONAL HERNIA AFTER RENAL TRANSPLANTATION: A CASE REPORT
2008
Objectives: We evaluated the incidence of incisional hernia after kidney transplantation, predisposing factors and the results of surgical repair of a giant incisional hernia by intraperitoneal PTFE dual mesh. Patients and methods: We report our experience about an incisional hernia in a 55 years male after renal transplantation treated with an intraperitoneal dual mesh prosthesis. The cause of incisional hernia was probably due to an urinoma for a total necrosis of distal graft ureter that needed to reopen in 2sd day post transplant with primary fascial approximation. Thirty days after transplantation we discovered a large incisional hernia that rapidly became monstrous with migration of o…
HUMAN FIBRIN GLUE SEALING VERSUS SUTURE POLYPROPYLENE FIXATION IN LICHTENSTEIN INGUINAL HERNIORRAPHY: A PROSPECTIVE OBSERVATIONAL STUDY.
2014
Background: Patients who underwent primary inguinal hernia repair still report a high rate of postoperative pain after operation due to effect of mesh fixation by suture. An alternative is the use of human fibrin glue. We compared the two techniques. Methods: 468 patients randomly underwent primary inguinal hernia Lichtenstein repair fixing the mesh by suture or by human fibrin glue (HFG); in both cases themesh was fixed to the posterior wall of the inguinal canal and to the inguinal legament. results: No significant differences were recorded between the two groups in terms of complications, while the sutureless technique reduces the operative time and the postoperative pain. Conclusions: A…
The use of a tailored mesh with special design for ventral hernia repair. Preliminary report
2009
Introduction: The study describes a modified technique for ventral hernia repair based upon a tension free, fixation free, and dynamic compliant implant. Material and methods: A unique geometrical shaped light weighted, large porous polypropylene mesh was created consisting of a large central body and six radial arms, designed to pass through the tissues and hold the mesh in place without tension. We used the mesh in a small exploratory cohort of patients with ventral hernia. The mesh was placed sublay by taking each of the six straps and passing from below the muscle, through the muscle allowing the fixation free strap to sit with friction within the tissues. This was designed to give a te…
Absorbable suture materials for primary defect closure in congenital diaphragmatic hernia: long term outcome
2011
Congenital diaphragmatic hernia and esophageal atresia: The importance of respiratory follow-up in congenital thoracic malformations
2013
Esophageal atresia, congenital diaphragmatic hernia, pulmonary function test, respiratory morbidity, Long-term follow-up
A New Prosthetic Implant for Inguinal Hernia Repair: Its Features in a Porcine Experimental Model
2011
Even after more than 100 years of inguinal hernia repair, the rate of complications and recurrence remains unacceptably high. In the last decades, few effective advances in surgical technique and materials have been made. The authors see them as minor adjustments in the shape and materials of the prosthetic implants. Still, the underlying genesis of inguinal hernia remains undefined. Based upon this, it seems the surgical repair of inguinal protrusions cannot be based upon the pathogenesis because the etiology to date has not been addressed. Most hernia repairs are performed with some degree of point fixation (sutures/tacks) to stop the mesh from migrating and creating high recurrence rates…
Cytokines and growth factors in wound drainage fluid from patients undergoing incisional hernia repair
2006
Knowing the dynamics of growth factor and cytokine secretion within the site of a surgical operation is important, as they play a crucial role in the pathophysiology of wound healing and are a target for modifying the repair response. The aim of this study was to evaluate the production of several cytokines and growth factors in the drainage wound fluid from patients undergoing incisional hernia repair: namely, interleukin (IL)-6, IL-10, IL-1alpha, IL-1 ra, interferon-gamma, vascular endothelial growth factors and basic fibroblast growth factor. Ten female patients with abdominal midline incisional hernia undergoing surgical repair were included in this study. In all cases, a closed-suction…
Laparoscopic Epigastric Hernia Repair
2016
Epigastric hernias are midline abdominal wall defects located between the umbilicus and the xiphoid process that do not resolve spontaneously. Symptomatic hernias require surgical repair.
Prenatal sonographic chest and lung measurements for predicting severe pulmonary hypoplasia.
1999
Pulmonary hypoplasia was diagnosed sonographically in 32 fetuses from 20 to 33 weeks of gestation. In addition to standard biometry, transverse thoracic diameter (TTD), sagittal thoracic diameter (TSD), thoracic circumference (TC) and lung diameter (LD) were measured in all cases and compared with known nomograms. The fetuses were divided into five groups according to the main sonographic findings: group 1—skeletal dysplasia; group 2—renal agenesis; group 3—diaphragmatic hernia; group 4—hydrothorax; and group 5—others. Severe pulmonary hypoplasia (PH) was diagnosed prenatally in all cases on the basis of LD measurements. In 17 (53.1 per cent) out of 32 cases TTD was below the 5th percentile…