Search results for " hernia"
showing 10 items of 194 documents
Successful tracheal occlusion using ultrathin fetoscopic equipment combined with real-time three-dimensional ultrasound.
2008
<i>Objective:</i> The most common complication of intrauterine tracheal balloon occlusion is the preterm premature rupture of membranes (PPROM) which increases the rate of neonatal morbidity and mortality. Ultrathin fetoscopy may be a method of reducing the risk of PPROM. <i>Materials and Methods:</i> The operation was performed at the 27th week of gestation after sedation and relaxation of a fetus with bilateral congenital diaphragmatic hernia and with the liver lifted upwards into the thorax. An ultrathin sheath with a 1.2-mm fetoscope was used under real-time 3-D ultrasound guidance. The patient delivered in the 38th week of gestation and did not display PPROM aft…
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
De Garengeot Hernia: Case Report and Review of the Literature of a Rare Femoral Hernia
2021
AbstractDe Garengeot hernia is a rare femoral hernia defined as the presence of the appendix within the femoral hernia sac. The incidence of appendicitis in this type of hernia is a rare condition that accounts for 0.08–0.13% of all De Garengeot hernias. We describe the case of a 61-year-old woman that presented at the emergency department with a tender mass (diameter 10 × 8 cm) in the right groin region for 5 days associated with pain in lower right abdomen and accompanied by fever (38 °C). Computed tomography (CT) of the abdomen revealed the presence of a complex fluid collection with small foci of air in the right inguinal region, measuring 9 × 7 × 10 cm in the 3 orthogonal dimensions an…
Biologic Response of Inguinal Hernia Prosthetics: A Comparative Study of Conventional Static Meshes Versus 3D Dynamic Implants
2015
Despite improvements in prosthetics and surgi- cal techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars—typical results with con- ventional static implants and plugs—may contribute to these adverse events. Recently, a new type of 3D dynami- cally responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic respo…
Neomyogenesis in 3D Dynamic Responsive Prosthesis for Inguinal Hernia Repair
2018
Despite undisputed improvements, prosthetics hernia repair continues to be affected by unacceptable rates of complications. Postoperative adverse events such as discomfort and chronic pain represent a subject of increasing concern among the surgical community. Poor quality biologic response, stiff scar plates, and mesh shrinkage, a typical effect of conventional static meshes and plugs, are all indicated as the main reasons for many of the complications related to inguinal hernia repair. Even the conventional concept of treatment based upon a supposed reinforcement of the groin consequent to the fibrotic incorporation of meshes, would appear to be inadequate in the light of the latest scien…
Femoral, Direct, and Rare Inguinal Hernias in Children-An Update.
2017
AbstractPediatric surgeons deal with inguinal hernias on a regular basis. While most of these are straightforward in terms of diagnosis and therapy, occasionally what initially sounds like a routine case turns out to be a perplexing conundrum. This review discusses rare and unusual findings in the groin area that may mimic an indirect inguinal hernia, but are not. To provide good and effective care, pediatric surgeons should be readily familiar with the possible differential diagnosis of these entities, along with their specific management. In general, laparoscopy is one of the most useful interventions to discern unusual groin pathology from standard indirect inguinal hernias and in many c…
Acute inflammatory response after inguinal and incisional hernia repair with implantation of polypropylene mesh of different size.
2005
The purpose of this study was to assess the modifications of interleukin (IL)-6, C-reactive protein (CRP), leukocytes and fibrinogen after implantation of polypropylene mesh.Thirty-six patients were included in this study and divided into two groups. To the first group were allocated patients affected by inguinal hernia and undergoing conventional repair (subgroup Ia) or hernioplasty with 40-cm(2) polypropylene mesh (subgroup Ib). To the second group were allocated patients affected by incisional hernia and undergoing conventional repair (subgroup IIa) or incisional hernia repair with 400-cm(2) polypropylene mesh (subgroup IIb). Peripheral venous blood samples were collected 24 h before sur…
Eight-point compass rose underlay technique in 72 consecutive elderly patients with large incisional hernia
2011
Summary Background Repair of incisional hernia (IH) in the elderly is a challenge for the surgeon. Primary closure is preferable but is not always possible because of high recurrence rates of IH repaired without a prosthesis and/or possible respiratory and cardiovascular complications due to extreme tension of the margins. We report our experience with underlay mesh placement in elderly patients with large IH. Methods A total of 72 patients from January 2003 to December 2009 underwent IH repair involving placement of an intraperitoneal Gore® DualMesh® prosthesis. The prosthesis was first anchored at eight points in a compass rose pattern using a Gore® suture passer and then firmly secured t…