Search results for " image."

showing 10 items of 3908 documents

Multi axis representation and Euclidean distance of muscle fatigue indexes during evoked contractions

2014

International audience; In this article, we proposed a new representation of muscular fatigue during evoked muscle contractions based on fatigue indexes such as peak to peak amplitude, RMS of the M wave, mean and median frequency and fatigue index calculated from continuous wavelet transform (I CWT). These new representations of muscle fatigue using multi axis represented and Euclidean distance give better insights on changes in physiological characteristics during muscle fatigue. This technique provides a fatigue index using several muscle characteristics. The use of other kinds of fatigue characteristics as force could also be possible.

medicine.diagnostic_testMuscle fatigueSpeech recognitionMulti axis0206 medical engineeringMathematical analysis02 engineering and technologyElectromyography[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing020601 biomedical engineering[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEuclidean distance03 medical and health sciences0302 clinical medicineAmplitudeMuscular fatiguemedicineRepresentation (mathematics)[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing030217 neurology & neurosurgeryContinuous wavelet transform[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingMathematics
researchProduct

Digital Acquisition and Processing of Video Angiocardiograms

1986

Angiocardiographic diagnosis is still mainly based on the visual assessment of radiographic projection images recorded on photographic film. Considerable amounts of contrast material have to be selectively injected into the circulation in order to make the regions of diagnostic relevance visible in the superposition of the shadows of tissue and bone structures displayed in these transmission images. In addition, selective angiocardiography requires exact positioning of the catheter, a time-consuming procedure which is not without risk. The processing of the angiographie films obtained is difficult to maintain at a constant high quality level, and this introduces an disadvantageous delay bet…

medicine.diagnostic_testbusiness.industryComputer scienceInterface (computing)media_common.quotation_subjectImage processingTransmission (telecommunications)Optical transfer functionDigital image processingmedicineContrast (vision)Computer visionAngiocardiographyArtificial intelligenceProjection (set theory)businessmedia_common
researchProduct

Increasing Stability of EEG Components Extraction Using Sparsity Regularized Tensor Decomposition

2018

Tensor decomposition has been widely employed for EEG signal processing in recent years. Constrained and regularized tensor decomposition often attains more meaningful and interpretable results. In this study, we applied sparse nonnegative CANDECOMP/PARAFAC tensor decomposition to ongoing EEG data under naturalistic music stimulus. Interesting temporal, spectral and spatial components highly related with music features were extracted. We explored the ongoing EEG decomposition results and properties in a wide range of sparsity levels, and proposed a paradigm to select reasonable sparsity regularization parameters. The stability of interesting components extraction from fourteen subjects’ dat…

medicine.diagnostic_testbusiness.industryComputer sciencePattern recognition02 engineering and technologyElectroencephalographystability analysisRegularization (mathematics)ongoing EEG03 medical and health sciences0302 clinical medicinetensor decomposition0202 electrical engineering electronic engineering information engineeringmedicineTensor decompositionsparse regularization020201 artificial intelligence & image processingArtificial intelligencebusiness030217 neurology & neurosurgerynonnegative constraints
researchProduct

Real and simulated endoscopy of neurosurgical approaches in an anatomical model

1997

Endoscopy simulation is a new visualisation technique which can be used to visualise patient anatomy as seen through endoscopes. In the following, we describe the application of simulated endoscopy to neurosurgical endoscopic approaches. We assess different aspects of virtual images and their influence on the final result, as judged by clinicians. One of these aspects is the projective geometry which is used to render the 3D images. Rendering using stereographic projection leads to more realistic endoscopic views than perspective projection.

medicine.diagnostic_testbusiness.industryStereographic projectionVisualisation techniqueRendering (computer graphics)EndoscopyVirtual imageComputer graphics (images)medicineComputer visionArtificial intelligencebusinessProjective geometryMathematics
researchProduct

A boosting approach for prostate cancer detection using multi-parametric MRI

2015

International audience; Prostate cancer has been reported as the second most frequently diagnosed men cancers in the world. In the last decades, new imaging techniques based on MRI have been developed in order to improve the diagnosis task of radiologists. In practise, diagnosis can be affected by multiple factors reducing the chance to detect potential lesions. Computer-aided detection and computer-aided diagnosis have been designed to answer to these needs and provide help to radiologists in their daily duties. In this study, we proposed an automatic method to detect prostate cancer from a per voxel manner using 3T multi-parametric Magnetic Resonance Imaging (MRI) and a gradient boosting …

medicine.medical_specialty02 engineering and technology[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingcomputer.software_genremulti-parametric MRI03 medical and health sciencesProstate cancer0302 clinical medicineVoxelArea under curve0202 electrical engineering electronic engineering information engineeringmedicine[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingMulti parametricmedicine.diagnostic_testbusiness.industry020207 software engineeringMagnetic resonance imagingmedicine.diseaseprostate cancer3. Good healthMultiple factorsComputer-aided diagnosis030220 oncology & carcinogenesisGradient boostingcomputer-aided diagnosisGradient boostingRadiologybusinesscomputer[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing
researchProduct

Self-reported symptoms in women with diastasis rectus abdominis: A systematic review

2021

Abstract Introduction Diastasis rectus abdominis (DRA) diagnosis via clinical examination is well defined, however, the assessment of symptoms has been less investigated. Currently, there is also scant knowledge on the consequences of DRA. The aim of this review is to identify the relevant self-reported variables in the study of DRA in women. Methods We performed a systematic review of observational studies through Medline, Embase, and Cochrane Library databases. Studies evaluating the link between DRA and self-reported symptoms were searched using the following terms: "Diastasis rectus abdominis", "Diastasis recti", "Abdominis Rectus Muscle Diastasis", "Questionnaire", "Scale", "Survey", "…

medicine.medical_specialtyAbdominal painDiastasis MuscleRectus AbdominisUrinary incontinencePhysical examinationPelvic Floor DisordersDiagnostic Self Evaluation03 medical and health sciences0302 clinical medicinePelvic floor dysfunctionQuality of lifeBody ImagemedicineHumansDiastasis rectiMuscle Weakness030219 obstetrics & reproductive medicinemedicine.diagnostic_testbusiness.industryObstetrics and Gynecologymedicine.diseaseLow back painAbdominal PainReproductive Medicine030220 oncology & carcinogenesisQuality of LifeDiastasisPhysical therapyFemaleSelf ReportSymptom Assessmentmedicine.symptombusinessLow Back PainJournal of Gynecology Obstetrics and Human Reproduction
researchProduct

Motor asymmetry attenuation in older adults during imagined arm movements

2014

International audience; Laterality is an important feature of motor behavior. Several studies have shown that lateralization in right-handed young adults (i.e., right versus left arm superiority) emerges also during imagined actions, that is when an action is internally simulated without any motor output. Such information, however, is lacking for elderly people and it could be valuable to further comprehend the evolution of mental states of action in normal aging. Here, we evaluated the influence of age on motor laterality during mental actions. Twenty-four young (mean age: 24.7 +/- 4.4 years) and 24 elderly (mean age: 72.4 +/- 3.6 years) participants mentally simulated and actually execute…

medicine.medical_specialtyAgingAGE-RELATED DIFFERENCESRIGHT HANDSCognitive NeuroscienceRight armNormal agingIMAGERYLeft armLateralization of brain functionDevelopmental psychologylcsh:RC321-571Physical medicine and rehabilitationMotor imageryArm musclemedicineYoung adultMotor asymmetrylcsh:Neurosciences. Biological psychiatry. NeuropsychiatryOriginal Researchmovement durationNONDOMINANT ARMMuscle activationCORTICOSPINAL EXCITABILITYAGING BRAINPERFORMANCEMENTAL SIMULATIONTEMPORAL FEATURESMotor asymmetryLateralityLIMB DYNAMICSMotor Imagery[ SCCO ] Cognitive sciencePsychologyNeuroscience
researchProduct

3D reconstruction techniques made easy: know-how and pictures

2005

Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.

medicine.medical_specialtyAudiovisual Aids Computer Graphics Computer-Aided Design Humans Image Processing; Computer-Assisted/*methods Imaging; Three-Dimensional/*methods Motion Pictures as Topic Radiographic Image Interpretation; Computer-Assisted/methods Tomography; X-Ray Computed/methods User-Computer InterfaceMotion PicturesImage processingIterative reconstructionComputer-Assisted/*methods ImagingUser-Computer InterfaceImaging Three-DimensionalAudiovisual Aids Computer Graphics Computer-Aided Design Humans Image ProcessingComputer-Assisted/methods TomographyComputer GraphicsImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingSegmentationThree-Dimensional/*methods Motion Pictures as Topic Radiographic Image InterpretationTomographic reconstructionAudiovisual Aidsbusiness.industry3D reconstructionIndustrial computed tomographyX-Ray Computed/methods User-Computer InterfaceGeneral MedicineVisualizationComputer-Aided DesignRadiographic Image Interpretation Computer-AssistedRadiologybusinessTomography X-Ray Computed3D reconstruction techniquesInterpolation
researchProduct

Role of virtopsy in the post-mortem diagnosis of drowning.

2014

Purpose: Due to admitted limits of autopsy-based studies in the diagnosis of drowning, virtopsy is considered the new imaging horizon in these post-mortem studies. The aim of our study was to evaluate the role of virtopsy performed through computed tomography (CT) in the forensic diagnosis of drowning. Materials and methods: We retrospectively examined the CT data of four cadavers recovered from sea water and suspected to have died by drowning. Each patient underwent a full-body post-mortem CT scan, and then a traditional autopsy. Conclusion: To date, there are no autopsy findings pathognomonic of drowning. This study proves that virtopsy is a useful tool in the diagnosis of drowning in tha…

medicine.medical_specialtyAutopsyAUTOPSY VIRTOPSYSensitivity and SpecificityUser-Computer InterfaceVirtopsyPredictive Value of TestsCause of DeathmedicineCadaverHumansRadiology Nuclear Medicine and imaginghealth care economics and organizationsNoseNeuroradiologyRetrospective StudiesPostmortem DiagnosisRib cageDrowningbusiness.industryReproducibility of Resultssocial sciencesGeneral Medicinemedicine.anatomical_structureParanasal sinusesClavicleRadiographic Image Interpretation Computer-AssistedRadiologyAutopsybusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct

Ventricular Fibrillation detection using time-frequency and the KNN classifier without parameter extraction

2017

[ES] Este trabajo propone la detección de FV y su discriminación de TV y otros ritmos cardiacos basándose en la representación tiempo-frecuencia del ECG y su conversión en imágen como entrada a un clasificador de vecinos más cercanos (KNN) sin necesidad de extracción de parámetros adicionales. Tres variantes de datos de entrada al clasificador son evaluados. Los resultados clasifican la señal en cuatro clases diferentes: ’Normal’ para latidos con ritmo sinusal, ’FV’ para fibrilación ventricular, ’TV’ para taquicardia ventricular y ’Otros’ para el resto de ritmos. Los resultados para detección de FV mostraron 88,27% de sensibilidad y 98,22% de especificidad para la entrada de imágen equivale…

medicine.medical_specialtyBiomedical systemsGeneral Computer ScienceSeñales no estacionarias0206 medical engineeringTime-frequency representationClasificación02 engineering and technologyElectrocardiographic signalsVentricular tachycardiaNon-stationary signalsImage analysisAnálisis de imágenesInternal medicine0202 electrical engineering electronic engineering information engineeringmedicineSinus rhythmSistemas biomédicosbusiness.industrySeñales ElectrocardiográficasClassificationmedicine.disease020601 biomedical engineeringRepresentación tiempo-frecuenciaControl and Systems EngineeringSignal parameterVentricular fibrillationCardiology020201 artificial intelligence & image processingbusinessRevista Iberoamericana de Automática e Informática industrial
researchProduct