Search results for " implant"

showing 10 items of 1276 documents

CT angiography for the assessment of EVAR complications : a pictorial review

2022

Aortic aneurysm; Blood vessel prosthesis implantation; Endovascular procedures Aneurisma aórtico; Implantación de prótesis de vasos sanguíneos; Procedimientos endovasculares Aneurisma aòrtic; Implantació de pròtesis de vasos sanguinis; Procediments endovasculars Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complication…

:intervenciones quirúrgicas::procedimientos quirúrgicos cardiovasculares::procedimientos quirúrgicos vasculares::procedimientos endovasculares [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Cardiovascular Diseases::Vascular Diseases::Aneurysm::Aortic Aneurysm::Aortic Aneurysm Abdominal [DISEASES]Aortic aneurysmR895-920:diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::interpretación de imágenes asistida por ordenador::tomografía computarizada por rayos X::angiografía por tomografía computarizada [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Otros calificadores::Otros calificadores::/diagnóstico por imagen [Otros calificadores]:enfermedades cardiovasculares::enfermedades vasculares::aneurisma::aneurisma de la aorta::aneurisma de la aorta abdominal [ENFERMEDADES]Blood vessel prosthesis implantation:Surgical Procedures Operative::Cardiovascular Surgical Procedures::Vascular Surgical Procedures::Endovascular Procedures [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]Medical physics. Medical radiology. Nuclear medicineVasos sanguinis - CirurgiaEndovascular procedureEndovascular procedures:Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Image Interpretation Computer-Assisted::Tomography X-Ray Computed::Computed Tomography Angiography [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]cardiovascular systemRadiology Nuclear Medicine and imagingAbdominalStentsAngiografiacardiovascular diseasesComputed tomography angiography:Other subheadings::Other subheadings::/diagnostic imaging [Other subheadings]Educational ReviewAneurisma abdominal - Imatgeria
researchProduct

Accuracy combining different brands of implants and abutments

2013

Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to- abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands,…

AbutmentDentistryDental AbutmentsOdontologíaProsthesis DesignVertical fitSem micrographsProsthesis fittingDental AbutmentsClinical and Experimental DentistryProsthesis FittingCIENCIA DE LOS MATERIALES E INGENIERIA METALURGICATorqueProsthesis designGeneral DentistryProsthetic abutmentMathematicsDental Implantsbusiness.industryImplant:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTorqueOtorhinolaryngologyCombinationUNESCO::CIENCIAS MÉDICASDentalResearch-ArticleSurgeryImplantbusiness
researchProduct

Highly efficient isotope separation and ion implantation of  163Ho for the ECHo project

2019

Abstract The effective electron neutrino mass measurement in the framework of the ECHo experiment requires radiochemically pure 163 Ho, which is ion implanted into detector absorbers. To meet the project specifications in efficiency and purity, the entire process chain of ionization, isotope separation , and implantation of 163Ho was optimized. A new two-step resonant laser ionization scheme was established at the 30 kV magnetic mass separator RISIKO. For ionization and separation, an average efficiency of 69 ( 5 )  stat(4)sys% was achieved using intra-cavity frequency doubled Ti:sapphire lasers. The implantation of undesired 166 m Ho, which is present in trace amounts in the initial  163Ho…

Accelerator Physics (physics.acc-ph)PhysicsNuclear and High Energy PhysicsAtomic Physics (physics.atom-ph)Orders of magnitude (temperature)DetectorAnalytical chemistryFOS: Physical sciencesLaser01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasIsotope separationlaw.inventionIonIon implantationlawIonization0103 physical sciencesSapphirePhysics - Accelerator Physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

On the use of the electromechanical impedance technique for the assessment of dental implant stability: Modeling and experimentation

2014

We propose the electromechanical impedance technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. A three-dimensional finite element model of a transducer bonded to the abutment of a dental implant placed in a host bone site was created to simulate the progress of the tissue healing that occurs after surgery. The healing was modeled by changing the …

AdmittanceMaterials scienceMechanical Engineeringmedicine.medical_treatmentfinite element methodosseointegrationPiezoelectricityFinite element methodOsseointegrationTransducerdental implant stabilitymedicineGeneral Materials ScienceImplantDental implantElectromechanical impedance techniqueAbutment (dentistry)Biomedical engineering
researchProduct

Endometrial receptivity revisited: endometrial transcriptome adjusted for tissue cellular heterogeneity

2018

Study question Does cellular composition of the endometrial biopsy affect the gene expression profile of endometrial whole-tissue samples? Summary answer The differences in epithelial and stromal cell proportions in endometrial biopsies modify the whole-tissue gene expression profiles and affect the results of differential expression analyses. What is already known Each cell type has its unique gene expression profile. The proportions of epithelial and stromal cells vary in endometrial tissue during the menstrual cycle, along with individual and technical variation due to the method and tools used to obtain the tissue biopsy. Study design, size, duration Using cell-population specific trans…

Adult0301 basic medicineCell typeStromal cellBiopsyContext (language use)BiologyReal-Time Polymerase Chain ReactionEndometriumAndrologyTranscriptomeEndometriumYoung Adult03 medical and health sciences0302 clinical medicineGene expressionBiopsymedicineHumansEmbryo ImplantationMenstrual Cycle030304 developmental biology0303 health sciences030219 obstetrics & reproductive medicinemedicine.diagnostic_testReverse Transcriptase Polymerase Chain ReactionSequence Analysis RNAGene Expression ProfilingRehabilitationObstetrics and GynecologyEpithelial CellsGene expression profiling030104 developmental biologymedicine.anatomical_structureReproductive MedicineFemaleStromal CellsEndometrial biopsyHuman Reproduction
researchProduct

Transcriptional analysis distinguishes breast implant-associated anaplastic large cell lymphoma from other peripheral T-cell lymphomas

2019

Breast implant-associated anaplastic large cell lymphoma is a new provisional entity in the revised World Health Organization classification of lymphoid malignancies, the pathogenesis and cell of origin of which are still unknown. We performed gene expression profiling of microdissected breast implant-associated anaplastic large cell lymphoma samples and compared their transcriptional profiles with those previously obtained from normal T-cells and other peripheral T-cell lymphomas and validated expression of selected markers by immunohistochemistry. Our results indicate that most breast implant-associated anaplastic large cell lymphomas exhibit an activated CD4+ memory T-cell phenotype, whi…

Adult0301 basic medicinePathologymedicine.medical_specialtyBreast ImplantsCell of originT cell2734BiologyPathology and Forensic Medicine03 medical and health sciences0302 clinical medicineImmunophenotypingMyeloid Cell Differentiationhemic and lymphatic diseasesmedicineHumansRPS10Anaplastic large-cell lymphomaBreast implant-associated anaplastic large cell lymphomabreast implant-associatedanaplastic large cell lymphoma gene expression profiling RPS10Large cellLymphoma T-Cell Peripheralmedicine.diseaseimmunophenotypeLymphomaGene expression profiling030104 developmental biologymedicine.anatomical_structureTranscriptional analysi030220 oncology & carcinogenesisgene expressionLymphoma Large-Cell Anaplasticgene expression; C-Met; lymphoproliferative disorderFemaleC-Metlymphoproliferative disorderTranscriptome
researchProduct

Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft

2017

Abstract Objective One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human lipo…

Adult0301 basic medicinePathologymedicine.medical_specialtyTime FactorsCellular differentiationMyocytes Smooth MusclePopulationAdipose tissueCell Separation030204 cardiovascular system & hematologyMesenchymal Stem Cell TransplantationMuscle Smooth VascularArticleBlood Vessel Prosthesis Implantation03 medical and health sciences0302 clinical medicineLipectomyCell MovementBlood vessel prosthesisAnimalsHumansMedicineAorta AbdominaleducationCells CulturedBioprosthesiseducation.field_of_studyTissue EngineeringTissue Scaffoldsbusiness.industryAngiotensin IIMesenchymal stem cellCell DifferentiationMesenchymal Stem CellsAnatomyStromal vascular fractionAngiotensin IIBlood Vessel ProsthesisPhenotype030104 developmental biologyAdipose TissueRats Inbred LewFemaleSurgeryStromal CellsStem cellbusinessCardiology and Cardiovascular Medicine
researchProduct

Type of culture media does not affect embryo kinetics: a time-lapse analysis of sibling oocytes

2013

Are the morphokinetics of growing embryos affected by the type of culture media utilized?Morphokinetic parameters used for embryo selection are not affected between the two different concept culture media analyzed.Studies on the effect of culture media on human embryos have focused on evaluating different in-house and commercially available media as well as comparing outcomes among different commercial media. Nonetheless, the evaluation of embryo development in these studies was based on static observations and very little is known from a dynamic point of view.Prospective cohort study, October 2010 and April 2011.University-affiliated infertility center. Patients undergoing egg donation (n …

AdultAdolescentPregnancy RateBiologyTime-Lapse ImagingCohort StudiesAndrologyYoung AdultPregnancymedicineHumansEmbryo ImplantationProspective StudiesSiblingPregnancyOocyte DonationFifth thoracic vertebraRehabilitationObstetrics and GynecologyEmbryoAnatomymedicine.diseaseCulture MediaKineticsPregnancy rateBlastocystReproductive MedicineSpainOocyte donationOocytesPregnancy TwinEctogenesisFemaleBiomarkersHuman Reproduction
researchProduct

Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…

2006

To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.

AdultAgingmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentSoftware toolScheimpflug principleIrisHigh resolutionIntraocular lensPhakic intraocular lensPreoperative careImaging Three-DimensionalLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinePreoperative CaremedicineHumansComputer SimulationPostoperative PeriodIris (anatomy)Lens crystallinebusiness.industryeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Air bubble location inside the uterus after transfer: is the embryo really there?

2007

Objective To demonstrate that the location of the air bubble after embryo transfer (ET) does not necessarily indicate the final embryo location. Design Case report. Setting Private clinic. Patient(s) A couple with primary infertility for whom a diagnosis of bicornuate uterus with a very open angle between horns was confirmed. Intervention(s) Laparoscopy and hysteroscopy were performed before an IVF cycle in which a single embryo was replaced. Main Outcome Measure(s) Air bubble image immediately after ET and gestational sac location 3 weeks later. Result(s) Immediately after a single ET, the air bubble was seen in the left uterine horn. Three weeks later, a gestational sac was seen in the ri…

AdultBicornuate uterusmedicine.medical_specialtyGestational sacUterusPregnancymedicineHumansEmbryo ImplantationLaparoscopyUltrasonographyGynecologymedicine.diagnostic_testbusiness.industryAirUterusObstetrics and GynecologyEmbryoAnatomyEmbryo TransferEmbryo Mammalianmedicine.diseaseEmbryo transfermedicine.anatomical_structureReproductive MedicineHysteroscopyembryonic structuresFemaleAir bubblebusinessFertility and Sterility
researchProduct