Search results for " implant"
showing 10 items of 1276 documents
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
False positive rate of an arrayCGH platform for single-cell preimplantation genetic screening and subsequent clinical application on day-3
2013
In this work, false positive rate of an arrayCGH platform for its use in day-3 single-blastomere analysis was calculated. For this purpose, 38 embryos diagnosed as abnormal on day-3 by FISH were re-biopsied on day-4. Single-cell day-4 arrayCGH diagnosis was then performed. A successful amplification was obtained in 97.4 % (37/38) of the day-4 cells analysed by arrayCGH. Day-3 FISH and day-4 arrayCGH diagnosis were concordant in 35/37 cases. The two discordant embryos were spread and all the cells from each embryo were re-analysed by FISH on day 5. The same error rate (2.7 %) for day-3 FISH and day-4 arrayCGH was obtained when comparing day-5 FISH re-analysis. After this pre-clinical phase, …
Association of Left Ventricular Systolic Dysfunction Among Carriers of Truncating Variants in Filamin C With Frequent Ventricular Arrhythmia and End-…
2021
Importance: Truncating variants in the gene encoding filamin C (FLNCtv) are associated with arrhythmogenic and dilated cardiomyopathies with a reportedly high risk of ventricular arrhythmia.Objective: To determine the frequency of and risk factors associated with adverse events among FLNCtv carriers compared with individuals carrying TTN truncating variants (TTNtv).Design, Setting, and Participants: This cohort study recruited 167 consecutive FLNCtv carriers and a control cohort of 244 patients with TTNtv matched for left ventricular ejection fraction (LVEF) from 19 European cardiomyopathy referral units between 1990 and 2018. Data analyses were conducted between June and October, 2020.Main…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Extraction of Impacted Maxillary Canines With Simultaneous Implant Placement
2005
When impacted maxillary canines are not amenable to orthodontic traction or reimplantation, extraction is the only option available, followed by implant placement. If apical and ridge crest bone remains after the extraction of the maxillary canines, an immediate implant can be placed. The implant is anchored bicortically with good primary fixation. This article presents a new surgical technique that allows an immediate implant placement after the extraction of the maxillary canines. The full circumference of the implant is left without bone coverage, except for the apical and coronal area. The implant screw threads and the bone defect are covered with the bone shavings collected by the filt…
Maxillary sinus lift performed using ultrasound. Evaluation of 21 patients.
2008
Purpose: The aim of the present study was to evaluate the sinus membrane perforations that occurred during a sinus lift procedure using the ultrasound technique, and to evaluate the bone gain obtained. Materials and methods: In 21 patients, 26 sinus lifts were performed using ultrasound and filled with bone graft material. The bone height and the bone gain obtained were observed in postoperative orthopantomographs, correcting for previous distortion. Results: Of the 26 maxillary sinus lifts, 4 Schneiderian membrane perforations were observed. The average bone height prior to the intervention was 3.5 mm (scale 0.6- 8.7 mm ) and the average postsurgical bone height was 10.8 mm (scale 7.5- 15.…
Bone-to-implant contact of orthodontic implants in humans--a histomorphometric investigation
2008
The purpose of the present study was to evaluate the percentage of direct bone-to-implant contact (BIC) of orthodontic anchorage implants (Orthosystem) after active orthodontic treatment. Twenty orthodontic implants (diameter, 3.3 mm; length, 4 or 6 mm) were inserted for orthodontic anchorage in different anatomical regions of 18 adult patients (nine males, nine females) aged 18-63 years. Fifteen implants (one per patient) were placed in the mid-palatal area, one implant (one patient) in the retromolar area of the mandible, one in the retromolar area and the mid-palatal area (one patient), and two (bilaterally, one patient) in the zygomatic area. The duration of the unloaded healing period …
Vertical Mandibular Alveolar Bone Distraction and Dental Implant Placement: A Case Report
2006
Abstract Extensive bone defects complicate the adequate placement of dental implants and the required angulation. In such cases, alveolar-ridge augmentation techniques such as guided bone regeneration, particulate or block grafting, and alveolar bone distraction are needed. The present study describes a case in which a large vertical bone defect in the anterior mandibular zone was corrected via vertical alveolar bone distraction. Six dental implants were posteriorly placed for implant-supported restoration of the mandible, with early implant loading. The clinical and radiologic control showed good implant and soft tissue conditions 12 months later.