Search results for " implantation."

showing 10 items of 677 documents

Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the valve-in-ring case.

2022

Transcatheter mitral valve replacement (TMVR) has been used for “off-label” treatment when annuloplasty band ring for mitral repair fails. However, the complex anatomy and function of the mitral valve may lead to fatal complications as a result of the left ventricular outflow tract (LVOT) obstruction in TMVR. We report the structural and hemodynamic response of LVOT obstruction resulting from TMVR with the Edwards SAPIEN 3 Ultra (S3) device. We modified the original Living Heart Human Model (LHHM) to account for a failed mitral valve with an annuloplasty band ring and simulated the cardiac beating condition in the setting of S3 device implantation. Findings demonstrated a high dynamic behav…

Heart Valve Prosthesis ImplantationHeart Defects CongenitalHistoryCardiac CatheterizationPolymers and PlasticsRehabilitationBiomedical EngineeringBiophysicsMitral Valve InsufficiencyFinite Element (FE) analysisIndustrial and Manufacturing EngineeringVentricular Outflow ObstructionTreatment OutcomeRisk FactorsComputational Fluid Dynamic (CFD)Living heart human modelHeart Valve ProsthesisHumansMitral ValveOrthopedics and Sports MedicineBusiness and International ManagementTranscatheter mitral valve replacementJournal of biomechanics
researchProduct

Early symptomatic benefit indicates long-term prognosis after transcatheter mitral valve edge-to-edge repair in functional and degenerative etiology

2021

Mitral regurgitation (MR) is common in patients with heart failure and constitutes an independent risk factor for adverse prognosis besides NYHA-class. The predictive value of dyspnea reduction after transcatheter mitral valve repair (TMVr) on outcome has not been investigated up to now.We enrolled 627 consecutive patients (47.0% female, 57.4% functional MR; median follow-up 486 days[IQR 157/961]; survival status available in 96.8%; symptoms assessed in n = 556 at baseline / n = 406 at 1 month) treated with isolated percutaneous mitral valve edge-to-edge repair in our center from 06/2010-03/2018 (exclusion of combined forms of TMVr) in a monocentric retrospective analysis. Survival was 97.6…

Heart Valve Prosthesis ImplantationMaleMitral valve repairmedicine.medical_specialtyMitral regurgitationEjection fractionbusiness.industrymedicine.medical_treatmentMitraClipPrognosismedicine.diseaseSymptomatic reliefSurgeryTreatment Outcomemedicine.anatomical_structureInterquartile rangeHeart failureMitral valvemedicineHumansMitral ValveFemaleCardiology and Cardiovascular MedicinebusinessRetrospective StudiesInternational Journal of Cardiology
researchProduct

Impact of Prosthesis-Patient Mismatch after Mitral Valve Replacement

2016

Background and aim of the study: The study aim was to determine the impact of prosthesis-patient mismatch (PPM) on early and late clinical outcomes, left atrial and ventricular remodeling, late tricuspid valve regurgitation and pulmonary hypertension (PH) in patients after mitral valve replacement (MVR). Methods: A total of 46 patients (mean age 66 ± 9.3 years) with mitral valve diseases and undergoing isolated MVR was enrolled in the study. The mitral valve effective orifice area (EOA) was determined using the continuity equation and indexed for the patient’s body surface area (EOAi). PPM was defined as EOAi ≤1.2 cm2/m2. PH was defined as a systolic pulmonary artery pressure (sPAP) >40 mmH…

Heart Valve Prosthesis ImplantationMaleProsthesis-Patient MismatchHypertension PulmonaryHemodynamicsMitral Valve InsufficiencySettore MED/23 - Chirurgia CardiacaMitral Valve ReplacementMiddle AgedTricuspid Valve InsufficiencyTreatment OutcomeRisk FactorsHeart Valve ProsthesisProsthesis FittingHumansSettore MED/05 - Patologia ClinicaFemaleEmergenciesHospitals TeachingProsthesis-Patient Mismatch; Mitral Valve ReplacementAgedRetrospective Studies
researchProduct

Preoperative evaluation before MitraClip®: present and future perspective.

2014

ABSTRACT  Mitral regurgitation (MR) is the second most common heart valve disease worldwide. Currently, the management of MR is based on medical therapy (including biventricular pacing), surgery (mitral valve replacement or repair) and percutaneous therapy. However, in spite of guideline recommendations, 50% of individuals assessed in the Euro Heart Survey were not referred to surgical intervention due to comorbidities or real or perceived high risks for cardiac surgery; thus, in recent years, the focus of research has shifted to the development of percutaneous approaches to treat severe MR in order to restore valve function in a minimally invasive fashion. Among these techniques, the perc…

Heart Valve Prosthesis ImplantationMitral regurgitationmedicine.medical_specialtyPercutaneousbusiness.industrymedicine.medical_treatmentMitraClipPatient SelectionMitral valve replacementMitral Valve InsufficiencyGuidelineSurgeryCardiac surgerymedicine.anatomical_structureHeart Valve ProsthesisPreoperative CaremedicineMolecular MedicineHumansMitral ValveHeart valveCardiology and Cardiovascular MedicinebusinessPercutaneous Mitral Valve Repair
researchProduct

SIMPLE, SAFE AND EASY TECHNIQUE TO ENSURE THE CORRECT LENGTH OF ARTIFICIAL CHORDAE IN MITRAL VALVE REPAIR.

2007

Replacement of diseased chordae with Gore-Tex sutures (W. L. Gore & Assoc, Flagstaff, AZ) in patients with degenerative mitral valve insufficiency has become a standard technique used by surgeons in mitral valve repair with good long-term results. Nevertheless, determining the correct length of the artificial chordae has remained problematic. Although various procedures have been previously published, in this article we describe our approach used to achieve an accurate chordal height adjustment.

Heart Valve Prosthesis ImplantationPulmonary and Respiratory MedicineMitral valve repairmedicine.medical_specialtyVALVE REPAIR.business.industrymedicine.medical_treatmentHeart Valve DiseasesStandard techniquemedicine.anatomical_structureMitral valvemedicineChordae TendineaeHumansMitral ValveSurgeryIn patientArtificial OrgansRadiologyChordae tendineaeCardiology and Cardiovascular MedicinebusinessMitral valve surgery
researchProduct

Transgastric imaging-The key to successful periprocedural TEE guiding for edge-to-edge repair of the tricuspid valve.

2021

Intraprocedural transesophageal echocardiography (TEE) guidance plays an essential role in transcatheter repair therapy of the tricuspid valve (TV). So far, several different imaging concepts are in use. We propose an imaging protocol that fully addresses the morphological complexity of the TV and further offers efficacious workarounds for the frequently occurring restrictions of TV imaging in edge-to-edge repair of the TV. As a tertiary referral center with a large experience of more than 250 cases of transcatheter edge-to-edge repair (TEER) of the TV performed at the Heart Valve Center in Mainz/Germany, we have constantly adapted our peri-interventional echocardiographic approach to accom…

Heart Valve Prosthesis Implantationmedicine.medical_specialtyCardiac CatheterizationTricuspid valvebusiness.industryInterventional imagingTricuspid Valve Insufficiencymedicine.anatomical_structureEchocardiographymedicineKey (cryptography)Referral centerHumansRadiology Nuclear Medicine and imagingRadiologyEnhanced Data Rates for GSM EvolutionHeart valveTricuspid ValveCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealEchocardiography (Mount Kisco, N.Y.)REFERENCES
researchProduct

Epidural hematoma after cochlear implantation in a 2.5-year-old boy.

2005

OBJECTIVE Report a case of an epidural hematoma after cochlear implantation in a 2.5-year-old boy, the diagnostic and therapeutical emergency management, as well as the postinterventional course and rehabilitation of the child. STUDY DESIGN Retrospective case review. PATIENT Two and a half-year-old boy, suffering from early onset, profound sensorineural hearing loss had been diagnosed at an age of 1.5 years, which had been more severe on the right side initially, but had progressed to bilateral deafness. INTERVENTION AND COMPLICATION: Cochlear implantation on the left side, followed up by an extensive epidural hematoma, causing intracranial compression with a midline shift of 15 mm to the r…

Hematoma Epidural CranialMaleReoperationmedicine.medical_specialtyCritical CareInfarctionBilateral DeafnessAudiologyDeafnessDiagnosis DifferentialInfarction Posterior Cerebral ArteryEpidural hematomaPostoperative ComplicationsMidline shiftmedicine.arteryAnterior cerebral arterymedicineElectrocoagulationHumansDominance CerebralNeurologic Examinationbusiness.industryInfarction Middle Cerebral Arterymedicine.diseaseCochlear ImplantationMagnetic Resonance ImagingMeningeal ArteriesSensory SystemsTentoriumTemporal LobeSurgeryEpistaxisOtorhinolaryngologyIntracranial EmbolismChild PreschoolNeurology (clinical)ImplantOccipital LobeComplicationbusinessTomography X-Ray ComputedFollow-Up StudiesOtologyneurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
researchProduct

Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva

2013

PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…

HiperopiaHyperopiaPhacoemulsificationVisual acuityMiopíaLens implantation intraocularImplantación de lentes intraocularesMyopiaAgudeza visualLens cristallineCristalinoFacoemulsificación
researchProduct

Optical active centres in ZnO samples

2006

Abstract In recent years, there has been a resurgence in the interest in the use of ZnO (Eg ∼ 3.37 eV) as a material for a wide range of opto-emitter applications spanning visible and short wavelengths. Bulk, thin films and nanomaterials obtained using different synthesis methods have been investigated for optoelectronic and biotechnological device applications. Nominally undoped bulk samples typically present a myriad-structured near-band-edge recombination, mainly due to free/bound excitons and donor–acceptor pair transitions. Furthermore, deep level emission due to intrinsic defects and extrinsic impurities, such as transition metal ions, are commonly observed in different grades of bulk…

II–VI semiconductorsChemical vapour depositionLuminescencePhotoluminescenceMaterials scienceLaser depositionOptical spectroscopyAnalytical chemistryNanoparticleCrystal growthMaterials ChemistryColloidsThin filmRutherford backscatteringDopingNanoclustersCondensed Matter PhysicsNanocrystalsX-ray diffractionElectronic Optical and Magnetic MaterialsIon implantationNanocrystalCeramics and CompositesNanoparticlesCrystal growthPlasma depositionSingle crystalJournal of Non-Crystalline Solids
researchProduct

Immediate post-extraction implants placed in acute periapical infected sites with immediate prosthetic provisionalization : a 1-year prospective coho…

2020

Background Few studies have reported the outcomes of immediate placement at infected post-extraction sites. The aim of this study was to compare clinical and radiological outcomes of immediately placed implants with immediate prosthetic provisionalization in sockets with or without acute periapical pathology. Material and Methods A total of 100 patients with immediately placed implants with immediate provisionalization and 1- year of follow up were included (50 patients with acute periapical pathology and a control group of 50 patients without acute periapical pathology). Clinical parameters (bleeding on probing, buccal keratinized mucosa width, clinical recession, and probing depth) and ra…

Immediate Dental Implant LoadingPeri-implantitisPeriapical pathologyRadiographyBleeding on probingDentistry03 medical and health sciencesDental Implants Single-Tooth0302 clinical medicineHumansMedicineProspective StudiesTooth SocketProspective cohort studyGeneral Dentistrybusiness.industryResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Peri-ImplantitisImmediate provisionalizationTreatment OutcomeOtorhinolaryngologyRadiological weaponUNESCO::CIENCIAS MÉDICASTooth ExtractionSurgeryImplantmedicine.symptombusinessImplantologyFollow-Up Studies
researchProduct