Search results for " implantation."
showing 10 items of 677 documents
Anastomotic Pseudoaneurysm Complicating Renal Transplantation: Treatment Options
2010
Introduction: Anastomotic pseudoaneurysm following renal transplantation is uncommon. Indications for repair, treatment options and outcomes remain controversial. Report: We present 6 renal transplant recipients with large anastomotic pseudoaneurysms. Five of the patients underwent open repair while one had a stent-grafting and delayed transplant nephrectomy for a ruptured pseudoaneurysm. A transplant nephrectomy was needed in all cases but one. Arterial reconstruction enabled limb salvage in all cases. One patient died of sepsis postoperatively. No patient presented late infection, failure of vascular reconstruction, nor pseudoaneurysm recurrence. Conclusions: Surgical excision of anastomo…
Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results
2018
Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…
Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm
2010
Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…
Results of chimney endovascular aneurysm repair as used in the PERICLES Registry to treat patients with suprarenal aortic pathologies
2020
Background: The prevailing evidence calls for using chimney/snorkel endovascular repair (ch-EVAR) with one or two chimney grafts. No studies up to now focus on its applicability and results for the treatment of suprarenal aortic pathologies (SRAP). Hence, we evaluated the clinical and radiologic results of ch-EVAR treatment for SRAP placing three or more chimney grafts within the PERICLES Registry. Methods: Data from 517 patients suffering complex aortic pathologies treated by ch-EVAR between 2008 and 2014 at 13 European and U.S. centers were retrospectively reviewed and analyzed. Results: Sixty-seven ch-EVAR-treated patients (12.9% of the entire PERICLES cohort) presented SRAP (83.5% elect…
Sequential Femorodistal Composite Bypass with Second Generation Glutaraldehyde Stabilized Human Umbilical Vein (HUV)
2005
Abstract Objective To evaluate the performance of sequential composite bypasses with second generation glutaraldehyde stabilized human umbilical vein (HUV) and autologous vein. Design Retrospective study of consecutive patients, in a single centre. Patients From January 1998 to December 2003, 54 femoro-distal HUV-autologous vein sequential composite bypasses were constructed in 52 patients with critical leg ischemia and absence of sufficient length of autologous vein. Methods All infra-inguinal bypass operations were registered in a computerized database and prospectively followed. Bypasses using sequential HUV-composite technique were reviewed for graft patency, limb salvage and patient su…
Outcomes of complex femorodistal sequential autologous vein and biologic prosthesis composite bypass grafts
2014
Objective Femorodistal autologous vein bypass proves to be the preferred surgical therapy for long arterial occlusions and provides excellent early and long-term results in critical lower limb ischemia. Whenever vein length was insufficient and two distal outflow arteries were present, a sequential composite bypass configuration was chosen with human umbilical vein (HUV) or ovine collagen prosthesis (Omniflow II; Bio Nova International Pty Ltd, North Melbourne, Australia) as the proximal prosthetic part of the bypass. Single-center experience with this technique regarding limb salvage, graft function, secondary reinterventions, and biodegeneration is presented. Methods Between January 1998 …
Outcomes of cataract surgery in diabetic patients: results of the Pan American Collaborative Retina Study Group.
2014
Purpose: This study was designed to evaluate the visual and anatomical outcomes after cataract surgery in diabetic patients with different intraoperative therapeutic strategies. Methods: The research design comprised of a multicentric, retrospective, interventional study conducted at 6 centers in Argentina, Brazil, Costa Rica, Puerto Rico, Spain, and Venezuela. We included 138 diabetic patients with at least 6-month follow-up following phacoemulsification and intraocular lens implantation. Best-corrected visual acuity (BCVA) and central subfield thickness were collected at baseline and at 1-, 2-, 3-, and 6-month follow-up. Of these, 42 cases were not treated with any intraoperative coadjuva…
Visual function comparison of 2 aspheric multifocal intraocular lenses
2011
To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Comparative case series.Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured.The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.0…
Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2012
PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…