Search results for " implantation."

showing 10 items of 677 documents

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Renewed endovascular repair for recurrent acute abdominal aortic aneurysm

2008

The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperative…

Malemedicine.medical_specialtyEndoleak type IIIRecurrent acuteSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsRecurrenceEndovascular repairBack painmedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAcute abdominal aortic aneurysmAged 80 and overEndoleak type IIbusiness.industrymedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeTreatment Outcomecardiovascular systemEmergency MedicineRadiologymedicine.symptombusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Canonical Babbling and Early Hearing and Language Development of Normal Hearing Children and Children with Cochlear Implants

2010

(2010). Canonical Babbling and Early Hearing and Language Development of Normal Hearing Children and Children with Cochlear Implants. Cochlear Implants International: Vol. 11, Proceedings of the 9th European Symposium on Paediatric Cochlear Implantation, Warsaw, 2009, pp. 375-378.

Malemedicine.medical_specialtyHearing Loss SensorineuraleducationAudiologyLanguage DevelopmentBabblingSpeech and HearingHearingReference Valuesotorhinolaryngologic diseasesHumansMedicineLongitudinal StudiesCochlear implantationhealth care economics and organizationsVerbal Behaviorbusiness.industryAge FactorsInfantPrognosisLanguage developmentCochlear ImplantsOtorhinolaryngologyCase-Control StudiesFemalesense organsbusinessChild LanguageCochlear Implants International
researchProduct

Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.

2012

Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…

Malemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensFundus (eye)PupilPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansIntraocular PressureAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationCataract surgerySulcusMiddle AgedPosterior Capsular Rupture Oculareye diseasesSurgeryOphthalmologymedicine.anatomical_structureFemalesense organsmedicine.symptombusinessEuropean journal of ophthalmology
researchProduct

Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery.

2007

Purpose To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri.Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with…

Malemedicine.medical_specialtyMicrosurgerygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularCorneaOphthalmologymedicineContrast (vision)HumansProspective StudiesCapsulorhexismedia_commonAgedLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedeye diseasesSensory SystemsSurgeryOphthalmologySpherical aberrationmedicine.anatomical_structureSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.

2011

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…

Malemedicine.medical_specialtyOptics and PhotonicsVisual acuityMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMedicineContrast (vision)Humansmedia_commonAgedAged 80 and overLenses Intraocularbusiness.industryStrehl ratioGeneral MedicineMiddle AgedOphthalmologySpherical aberrationFemalemedicine.symptombusinessPhotopic visionEuropean journal of ophthalmology
researchProduct

A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…

2012

Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …

Malemedicine.medical_specialtyPercutaneousTime Factorsmedicine.medical_treatmentAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive Diseases610 Medicine & healthConstriction PathologicAnastomosisProsthesis DesignAortographyIliac Artery2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPostoperative Complicationsmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingVascular CalcificationAgedAortabusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresSuture TechniquesStentExternal iliac arteryGeneral MedicineMiddle Agedmedicine.diseaseConstrictionSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeBypass surgerySurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computed
researchProduct