Search results for " implantation."
showing 10 items of 677 documents
Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.
2012
To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …
Reconstruction of large mandibular and surrounding soft-tissue defects using distraction with bone transport.
2012
Reconstruction of large bone and soft-tissue defects of the inferior third of the face is possible using various surgical techniques. Patients who require these procedures need to be in good general health, may have sequelae linked to donor sites, and require several interventions to achieve good aesthetic and functional results. The aim of this study was to report outcomes in patients with large mandibular and soft-tissue defects treated using osteogenic distraction with bone transport. Between 2001 and 2008, 14 patients had distraction with bone transport. Most patients were men (92.1%). The mean age was 43.1 years. The average mandibular bone reconstruction was 13.6 cm. The mean duration…
Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery
2005
Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…
Incidence of posterior vitreous detachment after cataract surgery
2009
Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…
Immediate Implant Placement in Fresh Mandibular Molar Extraction Socket: 8-Year Results. A Case Report
2010
Abstract Recently, successful implant placement in fresh extraction sockets has been reported. In this case report, we present the results of an immediate implant placement in a fresh extraction socket of a mandibular molar with simultaneous bone regeneration using a nonresorbable membrane and no other graft materials. Clinical and radiographic findings acquired 8 years after implant placement demonstrated a stable peri-implant situation and confirmed a satisfactory treatment result.
Maintenance of Class III Trifurcated Molars Versus Implant Placement in Regenerated Extraction Sockets: Long-Term Results of 2 Cases
2011
Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years.…
Mandibular Molar Root Resection Versus Implant Therapy: A Retrospective Nonrandomized Study
2009
AbstractSuccess rates for both periodontal and implant therapy are often dependent on site and tooth type. For periodontally involved mandibular molars, the decision to hemisect or to extract and place an implant is often complicated. The purpose of the present study was to evaluate the outcomes of the aforementioned treatment modalities for mandibular molars in a private practice setting. A retrospective chart review was performed. In one group of patients (n = 32), 56 mandibular first or first and second molars were treated by hemisection (Group H). A second group (n = 28) received 36 implants in the mandible to replace periodontally involved first or first and second molars (Group I). Al…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery
2013
To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…
Anatomic site evaluation of the palatal bone for temporary orthodontic anchorage devices.
2008
: Objectives: The aim of the present study was to assess the micromorphologic characteristics of the palatal bone from an implantologic standpoint. Materials and Methods: The material consisted of tissue blocks of autopsy material from 22 subjects (18 males, three females) between 18 and 63 years of age. The specimens comprised the anterior median palatal region from 5 to 10 mm behind the incisive foramen. They were prepared in the transversal plane according to ground thin-section technology. The midpalatal area as well as an area of 3 mm bilateral to the midline were assessed, and a classification of quantitative palatal bone availability was developed. Results: The findings could be divi…