Search results for " interface"
showing 10 items of 1741 documents
Fabrication and characterization of vacuum deposited fluorescein thin films
2011
Simple vacuum evaporation technique for deposition of dyes on various solid surfaces has been developed. The method is compatible with conventional solvent-free nanofabrication processing enabling fabrication of nanoscale optoelectronic devices. Thin films of fluorescein were deposited on glass, fluorine-tin-oxide (FTO) coated glass with and without atomically layer deposited (ALD) nanocrystalline 20 nm thick anatase TiO2 coating. Surface topology, absorption and emission spectra of the films depends on their thickness and the material of supporting substrate. On a smooth glass surface the dye initially formes islands before merging into a uniform layer after 5 to 10 monolayers. On FTO cove…
Present status and first results of the final focus beam line at the KEK Accelerator Test Facility
2011
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.
Polarization-Dependent Disappearance of a Resonance Signal -- Indication for Optical Pumping in a Storage Ring?
2021
We report on laser spectroscopic measurements on Li$^+$ ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F=\frac{3}{2}) \,\leftrightarrow\,2p\,^3\!P_2\;(F=\frac{5}{2}) \leftrightarrow 2s\,^3\!{S}_1\;(F=\frac{5}{2})$ $\Lambda$-transition in $^7$Li$^+$ with two superimposed laser beams it was found that the use of circularly polarized light leads to a disappearance of the resonance structure in the fluorescence signal. This can be explained by optical pumping into a dark state of polarized ions. We present a detailed theoretical analysis of this process that supports the interpretation of optical pumping and demonstrate…
Direct Measurement of Focusing Fields in Active Plasma Lenses
2018
Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801
Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider
2014
The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…
Characterization and Tuning of Ultra High Gradient Permanent Magnet Quadrupoles
2009
The application of quadrupole devices with high field gradients and small apertures requires precise control over higher order multipole field components. We present a new scheme for performance control and tuning, which allows the illumination of most of the quadrupole device aperture because of the reduction of higher order field components. Consequently, the size of the aperture can be minimized to match the beam size achieving field gradients of up to $500\text{ }\text{ }\mathrm{T}\text{ }{\mathrm{m}}^{\ensuremath{-}1}$ at good imaging quality. The characterization method based on a Hall probe measurement and a Fourier analysis was confirmed using the high quality electron beam at the M…
Virtual reality system for planning minimally invasive neurosurgery
2008
Object The authors report on their experience with a 3D virtual reality system for planning minimally invasive neurosurgical procedures. Methods Between October 2002 and April 2006, the authors used the Dextroscope (Volume Interactions, Ltd.) to plan neurosurgical procedures in 106 patients, including 100 with intracranial and 6 with spinal lesions. The planning was performed 1 to 3 days preoperatively, and in 12 cases, 3D prints of the planning procedure were taken into the operating room. A questionnaire was completed by the neurosurgeon after the planning procedure. Results After a short period of acclimatization, the system proved easy to operate and is currently used routinely for pre…
The “chimney forest” of the deep Montenegrin margin, south-eastern Adriatic Sea
2015
A spectacular field of columnar carbonates has been discovered on the Montenegrin margin in the southern Adriatic Sea at a depth of about 450 m. The site exposes many columnar carbonates protruding from the substrate or abated on the bottom. Such carbonates attain maximum visible lengths of ca. 60 cm with diameters up to 20 cm; display an annular growth, and are either hollow or plugged by indurated sediment. Petrographic and geochemical analyses document the pervasive presence of dolomite, and delta C-13 values as low as -30%(0) VPDB. These 'chimneys' are therefore interpreted as former conduits related to hydrocarbon expulsion in this sector of the Adriatic basin. However, available data …
Preparation and characterization of bio-organoclays using nonionic surfactant
2015
The present study was aimed at the preparation and characterization of tailor made hybrid materials, whose peculiar hosting capability could be exploited in biotechnological applications. With this purpose, the modification of K10 montmorillonite by intercalation of Tween 20 surfactant, was accomplished. The influence of two internal parameters, namely pH and surfactant/clay ratio, on the surfactant uptake ability by clay was investigated. The adsorption mechanism was elucidated on the basis of complementary kinetic and equilibrium studies and, then, corroborated by the useful information provided by the FT-IR, TGA and XRD characterization. The gathered results allow to draw the conclusion …
Fast Measurements of Adsorption on Porous Materials Using Jäntti's Method
1999
In 1972, Jäntti et al. formulated a method to shorten the time taken for adsorption measurements. We suggested at the Kiev International Conference on Vacuum Microbalance Techniques (1999) that the applicability of this method could be widened by considering a number of parallel adsorptions. There is, however, a more complicated but perhaps more interesting variant possible when extra mass transport is considered to occur in series. Such an application could involve adsorption within a porous structure where diffusion must be considered as a process occurring in series with adsorption on the surface.