Search results for " ionization"

showing 10 items of 621 documents

Detection of gamma-hydroxybutyrate in hair: Validation of GC–MS and LC–MS/MS methods and application to a real case

2012

A gas chromatography-mass spectrometry (GC-MS) and a liquid chromatography tandem mass spectrometry (LC-MS/MS) method were validated for quantifying endogenous and exogenous hair concentrations of gamma-hydroxybutyrate (GHB). The GC-MS method is based on overnight extraction of 25 mg hair in NaOH at 56 °C, liquid/liquid extraction in ethylacetate and trimethylsylil derivatization; analysis is by electron ionization and single ion monitoring of three ions. The LC-MS/MS method entails a rapid digestion of 25 mg hair with NaOH at 75 °C for 40 min, liquid/liquid extraction in ethylacetate and reconstitution of the extract in the LC mobile phase; negative ion electrospray ionization and multiple…

AdultMaleQuality ControlSpectrometry Mass Electrospray IonizationSubstance-Related DisordersElectrospray ionizationClinical BiochemistryLiquid-Liquid ExtractionPharmaceutical ScienceAcetatesTandem mass spectrometryMass spectrometryGas Chromatography-Mass SpectrometryAnalytical ChemistryForensic ToxicologySettore MED/43 - Medicina LegaleLiquid chromatography–mass spectrometryLimit of DetectionTandem Mass SpectrometryDrug DiscoveryHumansSodium HydroxideSpectroscopyDetection limitChromatographyChemistryIllicit DrugsSelected reaction monitoringHair Segmental analysis GC–MS LC–MS/MSTemperatureReproducibility of ResultsGamma hydroxybutyrateReference StandardsSubstance Abuse DetectionGamma-hydroxybutyrate GHBCalibrationLinear ModelsCrimeGas chromatography–mass spectrometrySodium OxybateChromatography LiquidHair
researchProduct

Identification of organic hydroperoxides and hydroperoxy acids in secondary organic aerosol formed during the ozonolysis of different monoterpenes an…

2009

On-line ion trap mass spectrometry (ITMS) enables the real-time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive-ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction-chamber experiments. APCI in the positive-ion mode usually enables the detection of [M+H](+) ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on-line APCI-ITMS is presented. Organic peroxides containing a hydroper…

AerosolsOrganic peroxideChemical ionizationAir PollutantsSpectrometry Mass Electrospray IonizationOzonolysisAtmospheric pressureOrganic ChemistryAnalytical chemistryCarboxylic AcidsAtmospheric-pressure chemical ionizationHydrogen PeroxideOnline SystemsIon sourceAnalytical ChemistryPeroxideschemistry.chemical_compoundchemistryFunctional groupMonoterpenesPressureVolatilizationHydrogen peroxideSesquiterpenesSpectroscopyRapid communications in mass spectrometry : RCM
researchProduct

Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…

2009

The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …

AerosolsSpectrometry Mass Electrospray IonizationChromatographyChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryExtractive electrospray ionizationMass spectrometryTandem mass spectrometryFourier transform ion cyclotron resonanceIon sourceAnalytical ChemistryTandem Mass SpectrometryCyclohexenesSpectroscopy Fourier Transform InfraredMonoterpenesDirect electron ionization liquid chromatography–mass spectrometry interfaceChromatography High Pressure LiquidSpectroscopyBicyclic MonoterpenesAmbient ionizationRapid Communications in Mass Spectrometry
researchProduct

Stochastic analysis of the critical velocity of an axially moving cracked elastic plate

2014

In this study, a probabilistic analysis of the critical velocity for an axially moving cracked elastic and isotropic plate is presented. Axially moving materials are commonly used in modelling of manufacturing processes, like paper making and plastic forming. In such systems, the most serious threats to runnability are instability and material fracture, and finding the critical value of velocity is essential for efficiency. In this paper, a formula for the critical velocity is derived under constraints for the probabilities of instability and fracture. The significance of randomness in different model parameters is investigated for parameter ranges typical of paper material and paper machin…

Aerospace EngineeringOcean EngineeringInstabilityRandomnessCivil and Structural EngineeringPhysicsta113Tension (physics)business.industryMechanical EngineeringplateIsotropypaperiStatistical and Nonlinear PhysicsMechanicsStructural engineeringmoving materialstabilityCondensed Matter PhysicsCritical valueCritical ionization velocityepävarmuusNuclear Energy and EngineeringfractureFracture (geology)businessAxial symmetryProbabilistic engineering mechanics
researchProduct

Rapid antibiotic susceptibility testing on blood cultures using MALDI-TOF MS

2018

International audience; Antibiotic resistance is a major public health problem requiring the early optimization of antibiotic prescriptions. Matrix-Assisted Laser Desorption Ionization-Time Of Flight Mass Spectrometry (MALDI-TOF MS) has been shown to accurately identify bacteria from positive blood culture. Here, we developed a rapid detection of Escherichia coli resistance to amoxicillin (AMX) and cefotaxime (CTX) from positive blood culture based on MALDI-TOF MS. Potential sparing of broad-spectrum antibiotics was also evaluated. We tested 103 E. coli-positive blood cultures. Blood cultures were subculture 1-hour in antibiotic-free rich liquid media before further incubation with and with…

Agar Dilution Method0301 basic medicineTime FactorsCefotaximePhysiologyAntibioticslcsh:MedicineCefotaximeDrug resistancemedicine.disease_causeMass SpectrometryAnalytical ChemistrySpectrum Analysis TechniquesAntibioticsMicrobial PhysiologyMedicine and Health SciencesBlood cultureMatrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometrylcsh:ScienceMultidisciplinarymedicine.diagnostic_testbiologyAntimicrobialsChemistryMicrobial Growth and DevelopmentDrugsMatrix-Assisted Laser Desorption Ionization Mass SpectrometryBody FluidsAnti-Bacterial Agents3. Good healthChemistryBlood[SDV.MP]Life Sciences [q-bio]/Microbiology and ParasitologyPhysical SciencesAnatomyResearch Articlemedicine.drugmedicine.drug_class030106 microbiologyMicrobial Sensitivity TestsResearch and Analysis MethodsMicrobiologyAntibiotic Susceptibility TestingMicrobiology03 medical and health sciencesMicrobial ControlDrug Resistance BacterialEscherichia colimedicineHumansEscherichia coliPharmacologyBacteriological TechniquesBacterial Growthlcsh:RBiology and Life SciencesAmoxicillinAmoxicillinbiology.organism_classificationPharmacologic AnalysisBlood CultureAntibiotic ResistanceSpectrometry Mass Matrix-Assisted Laser Desorption-Ionizationlcsh:QAntimicrobial ResistanceSubculture (biology)BacteriaDevelopmental BiologyPLOS ONE
researchProduct

Surfactant self-assembling in gas phase: electrospray ionization- and matrix-assisted laser desorption/ionization-mass spectrometry of singly charged…

2005

The self-assembling of sodium bis (2-ethylhexyl) sulfosuccinate (AOT) in gas phase has been investigated by electrospray ionization- and matrix-assisted laser desorption/ionization mass spectrometry. Large surfactant clusters with an aggregation number close to that found in apolar media have been observed either as positive or negative ions. Moreover, the marked predominance of singly charged species as well as preliminary theoretical calculations strongly suggest an aggregate structure characterized by an internal hydrophilic core hosting the extra charge surrounded by an apolar shell constituted by the surfactant alkyl chains. This structure is similar to that of the more familiar revers…

Aggregation numberChemistrygas-phase self-assemblyElectrospray ionizationsurfactantESI-MS and ESI-MS/MSAnalytical chemistryMass spectrometryMicelleMALDI-MSIonMatrix-assisted laser desorption/ionizationPulmonary surfactantIonizationSpectroscopyJournal of mass spectrometry : JMS
researchProduct

Classification of vegetable oils according to their botanical origin using amino acid profiles established by direct infusion mass spectrometry.

2007

Amino acid profiles, established by direct infusion mass spectrometry, have been used to classify vegetable oils according to their botanical origin. The proteins present in hazelnut, sunflower, corn, soybean, olive, avocado, peanut and grapeseed oils were precipitated with acetone, and the residue was hydrolyzed in acid medium, diluted in a hydrochloric acid/ethanol mixture, and infused into the mass spectrometer. The spectra of the hydrolyzed protein extracts showed [M+H]+ ions of the following amino acids: glycine, alanine, serine, proline, valine, threonine, cysteine, isoleucine + leucine, aspartic acid, lysine, glutamic acid, methionine, histidine, phenylalanine, arginine and tyrosine.…

Alaninechemistry.chemical_classificationSpectrometry Mass Electrospray IonizationHydrolyzed proteinMethionineChromatographyChemistryOrganic ChemistryDiscriminant AnalysisPhenylalaninePlantsAnalytical ChemistryAmino acidchemistry.chemical_compoundValinePlant OilsIsoleucineLeucineAmino AcidsSpectroscopyRapid communications in mass spectrometry : RCM
researchProduct

Determination of alcohols in essential oils by liquid chromatography with ultraviolet detection after chromogenic derivatization

2013

Abstract An HPLC-UV method to determine compounds having a hydroxyl functional group in plant essential oils is developed. The sample is diluted with 1,4-dioxane and the analytes are derivatized with phthalic anhydride. The derivatives (phthalates hemiesters) are separated on a C8 column using an acetonitrile (ACN)/water gradient. Separation conditions were optimized using the DryLab® method development software. For the alcohols and phenols present in mint and rose essential oils, optimization led to a ca. 40 min gradient time and a column temperature of 8 °C. The alcohol and its derivatives were identified using HPLC with mass spectrometry (MS) detection. A large sensitivity enhancement w…

AlcoholRosaMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrylaw.inventionchemistry.chemical_compoundLimit of DetectionlawOils VolatileFlame ionization detectorPhenolsDerivatizationDetection limitPhthalic anhydrideChromatographyOrganic ChemistryTemperatureReproducibility of ResultsGeneral MedicinechemistryAlcoholsPhthalic AnhydridesSpectrophotometry UltravioletChromatography LiquidMenthaJournal of Chromatography A
researchProduct

Supramolecular Aggregates in Vacuum: Positively Mono-Charged Sodium Alkanesulfonate Clusters

2010

The formation and structural features of positively mono-charged aggregates of sodium bis(2-ethylhexyl) sulfosuccinate (AOT) and sodium methane—(MetS), butane—(ButS) and octane—(OctS) sulfonate molecules in the gas phase have been investigated by electrospray ionization mass spectrometry, energy-resolved mass spectrometry and density functional theory (DFT) calculations. The experimental results show that the center-of-mass collision energy required to dissociate 50% of these mono-charged aggregates scantly depends on the length of the alkyl chain as well as on the aggregation number. This, together with the large predominance of mono-charged species in the mass spectra, was rationalized i…

AlkanesulfonatesSpectrometry Mass Electrospray IonizationAmphiphilic moleculeVacuumChemistryElectrospray ionizationSodiumSodiumSupramolecular chemistrychemistry.chemical_elementGeneral MedicineAtomic and Molecular Physics and Opticschemistry.chemical_compoundSulfonateTandem Mass SpectrometrySupramolecular aggregates amphiphilic molecules surfactants reversed micelles ESI MS ESI MS/MS energy resolved mass spectrometry DFT calculationsQuantum TheoryOrganic chemistrySpectroscopyEuropean Journal of Mass Spectrometry
researchProduct

Optical measurements of ground-state properties of short-lived nuclei in resonance cells

1985

Hyperfine structure and isotope shift of radioactive Hg, Au and Cd isotopes have been determined by optical spectroscopy. In all cases the atoms were confined in a resonance cell. The various variants of the cell technique and alternative methods as the resonance ionization spectroscopy related to the investigation of short-lived nuclei are described, and some results are discussed.

Alternative methodsNuclear and High Energy PhysicsIsotopeChemistryOptical measurementsResonanceCondensed Matter PhysicsAtomic and Molecular Physics and OpticsResonance ionizationPhysics::Atomic PhysicsPhysical and Theoretical ChemistryAtomic physicsNuclear ExperimentGround stateSpectroscopyHyperfine structureHyperfine Interactions
researchProduct