Search results for " laser"

showing 10 items of 1455 documents

Profiling of endogenous peptides by multidimensional liquid chromatography: On-line automated sample cleanup for biomarker discovery in human urine.

2009

A simple and flexible system, employing a column switching technique, has been designed to allow the analysis of peptides and proteins smaller than 15 kDa by molecular weight in filtered urine samples by performing a direct on-column injection utilising simultaneous sample clean-up and trace enrichment. The positively charged peptides and small proteins in the sample are attracted to the inner, negatively charged pore structure of the RAM-SCX column while the larger proteins and uncharged or negatively charged compounds are excluded. After preconditioning with the biological sample, large amounts of sample can be injected. Several important and adjustable parameters for the proper use of a …

ChromatographyChemistryIon chromatographyAnalytical chemistryReproducibility of ResultsFiltration and SeparationHydrogen-Ion ConcentrationMass spectrometryHigh-performance liquid chromatographyAnalytical ChemistryDilutionSpecimen HandlingMolecular WeightMatrix-assisted laser desorption/ionizationAdsorptionSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationSolid phase extractionPeptidesBiomarkersChromatography LiquidJournal of separation science
researchProduct

Size Exclusion Chromatography for Semipreparative Scale Separation of Au 38 (SR) 24 and Au 40 (SR) 24 and Larger Clusters

2011

Size exclusion chromatography (SEC) on a semipreparative scale (10 mg and more) was used to size-select ultrasmall gold nanoclusters (2 nm) from polydisperse mixtures. In particular, the ubiquitous byproducts of the etching process toward Au(38)(SR)(24) (SR, thiolate) clusters were separated and gained in high monodispersity (based on mass spectrometry). The isolated fractions were characterized by UV-vis spectroscopy, MALDI mass spectrometry, HPLC, and electron microscopy. Most notably, the separation of Au(38)(SR)(24) and Au(40)(SR)(24) clusters is demonstrated.

ChromatographyChemistrySize-exclusion chromatographyAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyMass spectrometry01 natural sciencesHigh-performance liquid chromatography0104 chemical sciencesAnalytical ChemistryNanoclusterslaw.inventionGel permeation chromatographyMatrix-assisted laser desorption/ionizationlawddc:540Electron microscope0210 nano-technologySpectroscopy
researchProduct

An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.

2002

A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…

ChromatographyIon exchangeChemistryIon chromatographyAnalytical chemistryProteinsUltrafiltrationFibroblastsMass spectrometryChromatography Ion ExchangeHigh-performance liquid chromatographyOnline SystemsPeptide MappingAnalytical ChemistryCell LineMatrix (chemical analysis)Matrix-assisted laser desorption/ionizationTwo-dimensional chromatographySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationElectrophoresis Polyacrylamide GelChromatography High Pressure LiquidAnalytical chemistry
researchProduct

MALDI-TOF characterization of macromonomers

1996

Methacryloyl endfunctionalized oligostyrene macromonomers were characterized by matrix assisted laser desorption ionization/time of flight (MALDI-TOF) spectroscopy and by isocratic and gradient high performance liquid chromatography (HPLC). The molar mass distribution derived by the different techniques coincide for the investigated oligomers. Mixing experiments revealed that the MALDI-TOF peak areas do not necessarily represent the mixing ratio of the components. Combination of gradient HPLC and MALDI-TOF has resolved the chemical composition of the coupling products formed by reaction of the living anion with oxygen.

ChromatographyPolymers and PlasticsChemistryOrganic ChemistryMatrix isolationAnalytical chemistryMass spectrometryMacromonomerHigh-performance liquid chromatographyTime of flightMatrix-assisted laser desorption/ionizationMaterials ChemistryMolar mass distributionSpectroscopyMacromolecular Rapid Communications
researchProduct

Excimer laser technology in percutaneous coronary interventions: Cardiovascular laser society's position paper

2022

Excimer Laser Coronary Atherectomy (ELCA) is a well-established therapy that emerged for the treatment of peripheral vascular atherosclerosis in the late 1980s, at a time when catheters and materials were rudimentary and associated with the most serious complications. Refinements in catheter technology and the introduction of improved laser techniques have led to their effective use for the treatment of a wide spectrum of complex coronary lesions, such as thrombotic lesions, severe calcific lesions, non-crossable or non-expandable lesions, chronic occlusions, and stent under-expansion. The gradual introduction of high-energy strategies combined with the contrast infusion technique has enabl…

Chronic occlusionAtherectomy CoronaryTechnologyAtherectomySevere calcific lesionChronic occlusions; ELCA; Laser angioplasty; Severe calcific lesions; Stent under-expansion; Thrombotic lesions; Coronary Angiography; Humans; Lasers Excimer; Technology; Treatment Outcome; Atherectomy Coronary; Percutaneous Coronary InterventionLasersCoronaryThrombotic lesionCoronary AngiographyChronic occlusionsExcimerTreatment OutcomePercutaneous Coronary InterventionStent under-expansionSevere calcific lesionsHumansLaser angioplastyLasers ExcimerELCACardiology and Cardiovascular MedicineThrombotic lesionsHumanInternational Journal of Cardiology
researchProduct

Instantaneous frequency measurement of dissipative soliton resonant light pulses

2016

Fil: Cuadrado-Laborde, Christian. Universidad de Valencia. Departamento de Física Aplicada y Electromagnetismo. Instituto Universitario de Ciencia de los Materiales; España Fil: Cuadrado-Laborde, Christian. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Física Rosario; Argentina Fil: Cuadrado-Laborde, Christian. Pontificia Universidad Católica Argentina. Facultad de Química e Ingeniería del Rosario; Argentina Fil: Armas Rivera, I. Benemérita Universidad Autónoma de Puebla. Facultad de Ciencias Físico Matemáticas; Mexico Fil: Carrascosa, A. Universidad de Valencia. Departamento de Física Aplicada y Electromagnetismo. Instituto Universitario de Ciencia de los Materia…

Ciencias FísicasInstantaneous frequencyPhysics::OpticsChirp spread spectrumMode-locking02 engineering and technology01 natural sciencesInstantaneous phase010309 opticsDissipative soliton020210 optoelectronics & photonicsOpticsFiber laser0103 physical sciencesDispersion (optics)0202 electrical engineering electronic engineering information engineeringChirpPhysics::Atomic PhysicsBAJA FRECUENCIAPhysicsbusiness.industryFiber laserAtomic and Molecular Physics and OpticsPulse (physics)AstronomíaMode-lockingLASER DE FIBRADissipative soliton resonancebusinessCIENCIAS NATURALES Y EXACTASBLOQUEO DE MODO
researchProduct

Cloning, purification, and nucleotide-binding traits of the catalytic subunit A of the V1VO ATPase from Aedes albopictus.

2007

The Asian tiger mosquito, Aedes albopictus, is commonly infected by the gregarine parasite Ascogregarina taiwanensis, which develops extracellularly in the midgut of infected larvae. The intracellular trophozoites are usually confined within a parasitophorous vacuole, whose acidification is generated and controlled by the V(1)V(O) ATPase. This proton pump is driven by ATP hydrolysis, catalyzed inside the major subunit A. The subunit A encoding gene of the Aedes albopictus V(1)V(O) ATPase was cloned in pET9d1-His(3) and the recombinant protein, expressed in the Escherichia coli Rosetta 2 (DE3) strain, purified by immobilized metal affinity- and ion-exchange chromatography. The purified prote…

Circular dichroismVacuolar Proton-Translocating ATPasesATPaseProtein subunitGene ExpressionGenes InsectBiologyIn Vitro Techniquesmedicine.disease_causelaw.inventionAdenosine TriphosphateATP hydrolysislawAedesCatalytic DomainmedicineAnimalsNucleotideCloning MolecularEscherichia coliDNA Primerschemistry.chemical_classificationPhotoaffinity labelingBase SequenceMolecular biologyProtein SubunitsSpectrometry FluorescenceBiochemistrychemistrySpectrometry Mass Matrix-Assisted Laser Desorption-Ionizationbiology.proteinRecombinant DNAInsect ProteinsBiotechnologyProtein expression and purification
researchProduct

Future Trends in Confocal Laser Endomicroscopy: Improved Imaging Quality and Immunoendoscopy

2007

Confocal laser endomicroscopy (CLE) is a powerful new technique that permits subsurface imaging at high resolution during ongoing endoscopy in the upper and lower GI tract [1]. Here, we will discuss future trends in CLE and their potential application in clinical practice. In particular, we will focus on molecular imaging using labelled antibodies for immunoendoscopy.

Clinical PracticeSubsurface imagingConfocal laser endomicroscopymedicine.medical_specialtybusiness.industryImaging qualityfungiHigh resolutionMedicineRadiologyMolecular imagingbusiness
researchProduct

Laser-Induced Plasma Emission Spectrometric Study of Pigments and Binders in Paper Coatings:  Matrix Effects

1998

Laser-induced plasma emission spectroscopy (LIPS) has been used to study inorganic pigment and organic binder distributions in paper coatings, which are inhomogeneous and porous materials. The plasma was generated by focusing a pulsed XeCl excimer laser beam (diameter 100 μm, irradiance 0.3 GW/cm2) on the sample surface at atmospheric pressure. A gated intensified CCD detector was used to record time-delayed emission spectra. Linear correlations between the LIPS signals and the coat weight and the binder content of the coatings studied were obtained. Emission line intensities from ionic and neutral magnesium atoms were used to evaluate plasma temperature corrections in determining silicon a…

Coated paperArgonExcimer laserAtmospheric pressureSiliconmedicine.medical_treatmentAnalytical chemistrychemistry.chemical_elementPlasmaLaserAnalytical Chemistrylaw.inventionchemistrylawmedicineEmission spectrumAnalytical Chemistry
researchProduct

On the use of SLS tools in sheet metal stamping

2003

Abstract A few rapid tooling technologies have been recently proposed and among them Selective Laser Sintering is probably one of the most relevant and promising. In the paper, the authors report some results of a wide experimental research on the application of SLS tools in sheet metal forming. A wear test was earned out to investigate the progressive degradation of laser-sintered materials in comparison with traditional cold-work steels. In particular SLS tools were utilized in a sheet metal stamping process of S-shaped parts: their performances (in terms of tool wear and dimensional quality of the stamped part) were compared with the ones of traditional tools.

Computer scienceMechanical EngineeringMechanical engineeringRapid toolingRapidManufacturing engineeringExperimental researchIndustrial and Manufacturing Engineeringlaw.inventionSelective laser sinteringWearlawSheet metal stampingvisual_artvisual_art.visual_art_mediumToolingTool wearSheet metal
researchProduct