Search results for " loading"

showing 10 items of 157 documents

Immediately provisionalized OsseoSpeed(™) Profile implants inserted into extraction sockets: 3-year results.

2015

Objectives A sloped shoulder might improve the congruence between extraction socket and dental implant and may add to a better circumferential support of the peri-implant structures. Therefore, this study evaluates the 3-year clinical outcome (survival and success rates, marginal bone levels, and Pink Esthetic Score (PES)) of immediately inserted and provisionalized OsseoSpeed(™) Profile implants in the anterior maxilla. Material and methods Twenty-one implants were inserted in 16 patients. All implants were immediately placed into extraction sites with and without facial bone deficiencies. A flapless procedure was utilized, and the implants were provisionalized immediately. Facial gaps wer…

AdultMaleImmediate Dental Implant LoadingFacial boneRadiographymedicine.medical_treatmentAnterior maxilla0206 medical engineeringDentistry02 engineering and technologyMandibleBone grafting03 medical and health sciences0302 clinical medicinemedicineHumansProspective StudiesAutogenous boneTooth SocketDental implantAgedDental ImplantsBone Transplantationbusiness.industrySoft tissue030206 dentistryMiddle Aged020601 biomedical engineeringTreatment OutcomeDental Prosthesis DesignFemaleImplantOral SurgerybusinessClinical oral implants research
researchProduct

Survival rates and bone loss after immediate loading of implants in fresh extraction sockets (single gaps). A clinical prospective study with 4 year …

2016

Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were ev…

AdultMaleImmediate Dental Implant LoadingTime FactorsAlveolar Bone LossDentistry03 medical and health sciencesDental Implants Single-Tooth0302 clinical medicinemedicineHumansDental Restoration FailureProspective Studies030212 general & internal medicineTooth SocketProspective cohort studyBone regenerationGeneral DentistryDental alveolusPeriodontitisbusiness.industryResearchMandible030206 dentistrySingle toothMiddle Aged:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseTreatment OutcomeOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASTooth ExtractionFemaleSurgeryImplantOral SurgerybusinessFollow-Up StudiesMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Influence of soft tissue grafting, orofacial implant position, and angulation on facial hard and soft tissue thickness at immediately inserted and pr…

2018

Background Resorption of hard and soft tissues following immediate implant insertion is frequently reported. Data regarding the influencing factors on facial tissue thickness are rare. Purpose This retrospective study investigated the impact of connective tissue grafting, the orofacial angulation and position of immediately inserted and provisionalized implants on the facial hard and soft tissue thickness in the anterior maxilla within a 1- to 5-year follow-up. Material and methods Implants with the prerequisite of having preoperative and postoperative cone beam computed tomography (CBCT) and a follow-up of 1 to 5 years were included. Facial bone deficiencies were grafted flaplessly with au…

AdultMalePeriodontiumCone beam computed tomographyImmediate Dental Implant LoadingFacial boneAdolescentConnective tissue03 medical and health sciencesYoung Adult0302 clinical medicineAlveolar ProcessMaxillaMedicineHumansBone regenerationGeneral DentistryAgedRetrospective StudiesOrthodonticsbusiness.industryDental Implantation EndosseousMouth MucosaSoft tissue030206 dentistryCone-Beam Computed TomographyMiddle AgedResorptionDental Restoration Temporarymedicine.anatomical_structure030220 oncology & carcinogenesisFacial tissueFemaleImplantOral SurgerybusinessClinical implant dentistry and related research
researchProduct

Effects of fatigue and recovery on electromyographic and isometric force- and relaxation-time characteristics of human skeletal muscle

1986

Effects of fatigue produced by a maintained 60% isometric loading on electromyographic and isometric force-time and relaxation-time characteristics of human skeletal muscle were studied in 21 males accustomed to strength training. Fatigue loading resulted in a slight but not significant change in the maximal integrated EMG of a maximal isometric contraction, and a large decrease (20.4 +/- 6.3%, p less than 0.001) in maximal force. Fatigue loading increased (p less than 0.05-0.01) neural activation of the muscles during rapidly produced submaximal isometric forces, but had a considerable adverse effect (p less than 0.001) on the corresponding force-time characteristics. Correlations between …

AdultMalemedicine.medical_specialtyContraction (grammar)PhysiologyStrength trainingIsometric exerciseElectromyographyPhysical medicine and rehabilitationIsometric ContractionPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineForce levelmedicine.diagnostic_testElectromyographyChemistryMusclesPublic Health Environmental and Occupational HealthSkeletal muscleGeneral MedicineKineticsmedicine.anatomical_structureFatigue loadingPhysical EnduranceCardiologymedicine.symptomMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Use of buccal fat pad to repair post-extraction peri-implant bone defects in the posterior maxilla: a preliminary prospective study

2015

Background: Extensive literature exists about the use of the BFP in the treatment of oral defects but, to our knowledge, no article refers to the use of the BFP as a substitute of the membrane barriers for treatment of peri- implant bone defects. The aim was to evaluate the use of the buccal fat pad as a coating material for bone grafting in the peri-implant bone defect regeneration of immediate implants placed in the posterior maxilla. Material and Methods: A preliminary prospective study of patients involving immediate implants in which the buccal fat pad was used as a coating material to peri-implant bone defects was carried out. The outcome measures assessed were: postoperative pain and…

AdultMalemedicine.medical_specialtyImmediate Dental Implant Loadingmedicine.medical_treatmentAlveolar Bone LossDentistryOdontologíaBone graftingPeri implant bonemedicineHumansProspective StudiesProspective cohort studyGeneral DentistryAgedBuccal fat padBone Transplantationbusiness.industryWound dehiscenceResearchMean ageAlveolar Ridge AugmentationMiddle Agedmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludSurgeryOtorhinolaryngologyAdipose TissueUNESCO::CIENCIAS MÉDICASSurgeryFemaleImplantOral SurgerybusinessPosterior maxilla
researchProduct

Neuromuscular fatigue and recovery in maximal compared to explosive strength loading.

1997

The purpose of this study was to examine acute neuromuscular fatigue and its recovery in men (n = 8) and women (n = 8). Two strenuous, but clearly different exercises were compared: maximal (MSL) versus explosive strength loading (ESL). The MSL included five sets of ten repetition maximum bilateral leg extensions. The same task and the same number of sets was performed in ESL but with 40% from the load used in MSL and performed as explosively as possible. Isometric force-time curves were measured during maximal voluntary bilateral isometric action of the leg extensors before the fatigue loading and after each set. The measurements were repeated after resting for 1 h, 2 h, 1 day and two days…

AdultMalemedicine.medical_specialtyWeight LiftingPhysiologyVastus medialisRepetition maximumNeuromuscular transmissionIsometric exerciseElectromyographyInternal medicineMedicineHumansLactic AcidMuscle SkeletalExercisemedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthExplosive strengthBiomechanical PhenomenaElectrophysiologyNeuromuscular fatigueFatigue loadingMuscle FatigueCardiologyPhysical therapyFemalebusinessMuscle ContractionEuropean journal of applied physiology and occupational physiology
researchProduct

Running in highly cushioned shoes increases leg stiffness and amplifies impact loading

2018

AbstractRunning shoe cushioning has become a standard method for managing impact loading and consequent injuries due to running. However, despite decades of shoe technology developments and the fact that shoes have become increasingly cushioned, aimed to ease the impact on runners’ legs, running injuries have not decreased. To better understand the shoe cushioning paradox, we examined impact loading and the spring-like mechanics of running in a conventional control running shoe and a highly cushioned maximalist shoe at two training speeds, 10 and 14.5 km/h. We found that highly cushioned maximalist shoes alter spring-like running mechanics and amplify rather than attenuate impact loading. T…

AdultMalemusculoskeletal diseasesrasitusvammatComputer sciencelcsh:MedicineHEEL STRIKEMASSbone quality and biomechanicsurheilujalkineetArticlejuoksuGROUND REACTION FORCES03 medical and health sciences0302 clinical medicineotorhinolaryngologic diseasesHumans315 Sport and fitness sciencesGround reaction forcelcsh:ScienceHeel strikeWORKLeg stiffnessLegMultidisciplinaryRunning injuriesbusiness.industryWork (physics)lcsh:Rtechnology industry and agricultureCushioning030229 sport sciencesStructural engineeringShoesbody regionsMECHANICSRUNNERSImpact loadingLoading rateINJURIESlcsh:Qbiomekaniikkabusiness030217 neurology & neurosurgeryScientific Reports
researchProduct

Exercise loading history and femoral neck strength in a sideways fall: A three-dimensional finite element modeling study

2016

Over 90% of hip fractures are caused by falls. Due to a fall-induced impact on the greater trochanter, the posterior part of the thin superolateral cortex of the femoral neck is known to experience the highest stress, making it a fracture-prone region. Cortical geometry of the proximal femur, in turn, reflects a mechanically appropriate form with respect to habitual exercise loading. In this finite element (FE) modeling study, we investigated whether specific exercise loading history is associated with femoral neck structural strength and estimated fall-induced stresses along the femoral neck. One hundred and eleven three-dimensional (3D) proximal femur FE models for a sideways falling situ…

AdultModels AnatomicGreater trochantermedicine.medical_specialtyHistologyAdolescentPhysiologyEndocrinology Diabetes and MetabolismFinite Element AnalysisPoison control030209 endocrinology & metabolismmedicine.disease_causeWeight-bearingWeight-BearingYoung Adult03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinemedicineHumansExerciseFemoral neckOrthodonticsexercise loading historyHip fractureProximal femurFemur Neckbusiness.industryfemoral neckDistal siteta3141030229 sport sciencesmedicine.diseaseMagnetic Resonance ImagingSurgerymedicine.anatomical_structureAthleteship fracturesAccidental FallsFemaleCortical bonebusinessBone
researchProduct

Neuromuscular performance and body mass as indices of bone loading in premenopausal and postmenopausal women.

2009

The strong association between body mass and skeletal robusticity has been attributed to increasing skeletal loading with increasing mass. However, it is unclear whether body mass is merely a coarse substitute for bone loading rather than a true independent predictor of bone strength. As indices of neuromuscular performance, impulse and peak power were determined from vertical ground reaction force during a maximal counter movement jump test in 221 premenopausal and 82 postmenopausal women. Bone compressive (BSI(d) g(2)/cm(4)) and bending (SSImax(mid) mm(3)) strength indices were measured with peripheral quantitative computed tomography (pQCT) at the distal ((d)) and midshaft ((mid)) sites …

Adultmedicine.medical_specialtyHistologyCompressive StrengthPhysiologyEndocrinology Diabetes and MetabolismMovementPhysical Exertion030209 endocrinology & metabolismIndependent predictorWeight-Bearing03 medical and health sciences0302 clinical medicineBone strengthBone loadingWeight lossOsteoarthritisMedicineHumansTibiaMuscle StrengthQuantitative computed tomography030304 developmental biologyOrthodontics0303 health sciencesHip fracturePostmenopausal womenmedicine.diagnostic_testTibiabusiness.industryBody WeightAge FactorsMiddle Agedmedicine.diseaseSurgeryPostmenopauseRadiographyPremenopauseBody CompositionRegression AnalysisFemaleStress Mechanicalmedicine.symptombusinessMuscle ContractionBone
researchProduct

Genetic and Environmental Influence on Structural Strength of Weight-Bearing and Non-Weight-Bearing Bone: A Twin Study

2007

A bivariate genetic analysis among 217 older female twin pairs showed that, although the structural strength of tibia and radius are mainly regulated by same genetic and environmental factors, the tibia is more affected by environment. Introduction: The habitual loading environment of the bone may modulate the relative contribution of genetic and environmental factors to bone structure. The purpose of this study was to estimate the contribution of the common and site-specific genetic and environmental factors to interindividual variation in compressive structural strength of the weight-bearing tibia and non–weight-bearing radius. Materials and Methods: pQCT scans were obtained from both mem…

AgingosteoporoosiEndocrinology Diabetes and MetabolismOsteoporosis030209 endocrinology & metabolismBone strengthEnvironmentBiologymedicine.disease_causeMechanical loadingBone and BonesWeight-bearing03 medical and health sciences0302 clinical medicineAnimal scienceBone DensityGenetic modelmedicineHumansOrthopedics and Sports MedicineTibia10. No inequalityAged030304 developmental biology0303 health sciencesmekaaninen kuormitusBody WeightEnvironmental factorAnatomyMiddle AgedHeritabilitymedicine.diseaseTwin studyperiytyvyysikääntyminenCompressive strengthluun lujuusTomography X-Ray ComputedJournal of Bone and Mineral Research
researchProduct