Search results for " microscopy"
showing 10 items of 1617 documents
Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik
2005
Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …
Radiation effects on light scattering and cataract formation in the lenses of interventional radiologist and cardiologists
2014
Purpose There is little information about exposure to dosages below 500 mSv. This pilot study aimed at investigating the effects of low dose radiation on lens transparency in occupationally exposed interventional cardiologists and radiologists. Methods Physicians who have performed fluoroscopically guided procedures for at least 5 years were recruited in the areas of Cologne-Bonn and Rhine-Main together with their non-exposed colleagues. A questionnaire has been developed to estimate occupational exposure. Exclusion criteria comprised corticosteroid treatment, radiotherapy, chemotherapy and glaucoma. Changes in lens transparency and cataract formation were determined by slit lamp microscopy…
Magnetic resonance microscopy and correlative histopathology of the infarcted heart
2019
Altres ajuts:The present study was supported by the EU Joint Programming Initiative 'A Healthy Diet for a Healthy Life' (JPI HDHL INTIMIC-085), Generalitat Valenciana (GV/2018/116), INCLIVA and Universitat de Valencia (program VLC-BIOCLINIC 20-nanomIRM-2016A). Delayed enhancement cardiovascular magnetic resonance (MR) is the gold-standard for non-invasive assessment after myocardial infarction (MI). MR microscopy (MRM) provides a level of detail comparable to the macro objective of light microscopy. We used MRM and correlative histopathology to identify infarct and remote tissue in contrast agent-free multi-sequence MRM in swine MI hearts. One control group (n = 3 swine) and two experimenta…
Myogenic effects enhance norepinephrine constriction: Inhibition by nitric oxide and felodipine
1998
Myogenic effects enhance norepinephrine constriction: Inhibition by nitric oxide and felodipine. Myogenic, pressure-induced vasoconstriction may amplify the effects of circulating vasoconstrictors. Through intravital microscopy in cremaster arterioles (31 to 115 μm diameter), the relative contribution of myogenic responses (MR) to norepinephrine (NE)-induced constriction and the inhibitor potency of nitric oxide (NO) or a Ca2+ entry blocker (CEB), felodipine (F), were examined. In 24 anesthetized hamsters, a vessel occluder was placed around the aorta to control cremaster vessel inflow pressure (IP). NE infusion increased blood pressure (by 50 ± 2mm Hg) and induced significant constriction …
INHIBITION OF CELLULAR GROWTH AND STEROID 11β-HYDROXYLATION INRAS-TRANSFORMED ADRENOCORTICAL CELLS BY THE FUNGAL TOXINS BETICOLINS
1996
Abstract The proliferation of GM16 and 4CDTras-transformed newborn rat adrenocortical (RTAC) cells and Y1 mouse adrenal tumor cells was inhibited by beticolins, the fungal toxins extracted fromCercospora beticola, at submicromolar concentrations in a dose-dependent manner. Inhibitory concentrations for half the maximum inhibition were 150, 75 and 25 n M for beticolin-1 and 230, 150 and 50 n M for beticolin-2 in GM16, 4CDT and Y1 cells respectively. Beticolins strongly inhibited the production of 11β-hydroxysteroids on the second and third days of treatment in a dose-dependent manner between 0.1 and 1 μ M . Beticolins were shown by confocal microscopy to be localized in cytoplasmic organelle…
Intravenous SPION-labeled adipocyte-derived stem cells targeted to the brain by magnetic attraction in a rat stroke model: An ultrastructural insight…
2021
Abstract Mesenchymal stem cell therapy after stroke is a promising option investigated in animal models and clinical trials. The intravenous route is commonly used in clinical settings guaranteeing an adequate safety profile although low yields of engraftment. In this report, rats subjected to ischemic stroke were injected with adipose-derived stem cells (ADSCs) labeled with superparamagnetic iron oxide nanoparticles (SPIONs) applying an external magnetic field in the skull to retain the cells. Although most published studies demonstrate viability of ADSCs, only a few have used ultrastructural techniques. In our study, the application of a local magnetic force resulted in a tendency for hig…
Investigation on the stability of dispersion of zirconia nanoparticles prepared by microwave- hydrothermal synthesis
2005
Difficulties in reproducing the performances of nanoparticles dispersions are obstructive for the progress of the nanotechnology. A plausible reason for this variability is the lack of the control of the stability as well as the dimensions of the nanoparticles in the dispersions. In this work we report results of investigations on the stability of zirconia nanoparticles in aqueous medium, monitoring nanoparticles sizes by means of Transmission Electron Microscopy (TEM), Dynamic Light Scattering (DLS). Nanocrystalline zirconia powders, prepared by microwave-hydrothermal synthesis, were determined to be 6-8 nm in size by TEM observations. By using DLS technique the as-prepared dispersions wit…
Adapter stabilizujący do długich preparatów mikroskopowych – budowa i zastosowanie w cyfrowym pozyskiwaniu obrazu
2018
Możliwość wykonywania, za pomocą mikrotomu typu „core--microtome”,preparatów z całych wywiertów wygenerowała problem związany ze stabilizacją preparatów podczas procesu pozyskiwania i zapis ich obrazu. Zaproponowane ostatnio dwa adaptery do długich preparatów mikroskopowych rozwiązały problem ich stabilizacji oraz umożliwiły kontrolę pozycji docelowych fragmentów w polu widzenia obiektywu. Konstrukcje te nie rozwiązują wszystkich potrzeb pojawiających się podczas pozyskiwania obrazu na potrzeby ilościowej anatomii drewna. W artykule proponujemy udoskonaloną wersję adaptera do długich preparatów mikroskopowych wychodzącą naprzeciw potrzebom użytkowników wcześniejszych wersji. Konstrukcje te …
Visualization of Moiré Magnons in Monolayer Ferromagnet
2023
| openaire: EC/H2020/788185/EU//E-DESIGN Two-dimensional magnetic materials provide an ideal platform to explore collective many-body excitations associated with spin fluctuations. In particular, it should be feasible to explore, manipulate, and ultimately design magnonic excitations in two-dimensional van der Waals magnets in a controllable way. Here we demonstrate the emergence of moiré magnon excitations, stemming from the interplay of spin-excitations in monolayer CrBr3 and the moiré pattern arising from the lattice mismatch with the underlying substrate. The existence of moiré magnons is further confirmed via inelastic quasiparticle interference, showing the appearance of a dispersion …
Synthesis, electron microscopy and X-ray characterization of oxymagnesite, MgO·2MgCO3, formed from amorphous magnesium carbonate
2014
At present, the peculiar compound called oxymagnesite, MgO·2MgCO3, an intermediate formed during thermal decomposition of hydrated magnesium carbonates, has only been described a handful of times without a distinct description of its formation or morphology. In the current work we present the first scanning and transmission electron microscopy images of an oxymagnesite crystal together with its crystallographic data. Oxymagnesite was synthesized in a controlled manner via decomposition of amorphous magnesium carbonates (AMCs) subjected to varying relative humidity. We show that oxymagnesite is formed only when AMC is hydrated above a certain level, which we attribute to structural inequival…