Rogowski coil current transducer compensation method for harmonic active power error
2015
Abstract In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method…
Design and Characterization of a New MV PLC Coupler for Smart Electric Energy Systems
2018
This paper deals with the design, modeling and characterization of a new coupling system for medium voltage (MV) narrow band power line communications (NB-PLC). It exploits the capacitive divider of voltage detecting systems (VDSs) normally used to reveal the mains voltage presence, thus avoiding the use of dedicated MV couplers. The proposed coupling system was patented by the authors. In this paper, the modeling of the VDS capacitive divider is presented, using a proper characterization method. Moreover, the interface card design is described, based on simulation of the whole PLC transmission channel. Laboratory tests are also presented and discussed. More in detail, a frequency response …
Fricke gel, electron spin resonance and thermoluminescence for integration and intercomparison of measurements in NCT dosimetry
2014
PVA-GTA Fricke gel: studio della risposta NMR in funzione della concentrazione degli additivi e studi preliminari con scanner MRI 7 T
2016
Sono stati analizzati tramite rilassometria NMR ed acquisizioni MRI dosimetri gel di tipo Fricke realizzati utilizzando un'innovativa matrice gel sintetica e tessuto equivalente: Polyvinyl alcohol (PVA) attivando chimicamente il processo di gelificazione tramite l'aggiunta di Glutaraldehyde (GTA). Questi gel sono stati irradiati con fasci di fotoni (LINAC) nel range 0--20 Gy. Per valutare la sensibilità a fotoni è stata studiata la dipendenza dei tempi di rilassamento nucleari dalla dose e dalla concentrazione di ferro nei gel. Inoltre è stata monitorata la stabilità del segnale dopo l'irraggiamento. Acquisizioni preliminari MRI con uno scanner MRI da 7 T sono state affiancate alle misure N…
Diffusion and sensitivity characteristics of a chemically cross-linked PVA-Fricke gel dosimeter
2016
Introduction: Current radiotherapy techniques implement treatment plans based on volumetric distributions of dose with complex shapes and sharp gradients. The agreement between these plans and the dose that is truly delivered is very challenging to verify. Thus, there is the need for a dosimetric system that is truly three dimensional, sensitive to radiation in each point and tissue equivalent. In this framework, great interest is encountered by radio-chromic gel dosimeters. In order to address the limitations of gels based on natural matrices, some investigators have proposed dosimeters based on poly vinyl alcohol (PVA) made by freezing-thawing cycles. Even though these gels have a low dif…
CARATTERIZZAZIONE DELL’ATTRITO SU COMPONENTI PER APPLICAZIONI ORTODONTICHE MEDIANTE UN SIMULATORE “IN VITRO”
2010
La diffusione delle tecniche a basso attrito (low friction) nell’ambito di terapie ortodontiche per lo spostamento di un dente mediante applicazione di una forza debole (0.5 – 0.7 N) o media (0.7-2.0 N) ha spinto la ricerca del settore odontoiatrico verso lo studio delle forze di attrito nel moto tra archetto ortodontico (archwire) e attacchi ortodontici (brackets). L’esame della letteratura ha mostrato alcuni approcci molto semplificati alla misura dell’attrito, con configurazioni piane, mediante simulazioni poco aderenti a quanto accade nel corso di una reale terapia ortodontica. Il presente lavoro si prefigge uno studio preliminare del fenomeno mediante caratterizzazione della forza di a…
A study on the effect of contact pressure during physical activity on photoplethysmographic heart rate measurements
2020
Heart rate (HR) as an important physiological indicator could properly describe global subject&rsquo
Equivalent detector models for the simulation of efficiency response of an HPGe detector with PENELOPE code
2019
Monte Carlo simulation of response of an HPGe detector is a widely used technique to evaluate counting efficiencies. It is particularly useful when calibration standards with the same shape and composition of the sample under examination are not available. The result of the simulation depends on the more or less detailed knowledge of the characteristics of the detector, able to define a "model" of the same detector. To highlight parts not well defined in the manufacturer's certification, a detector X-ray analysis is usually performed, except in cases when it is not possible to dismantle the shielding structure with the loss of previous calibration data. In this work, in absence of some data…
PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging
2016
Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…
A radiometric and petrographic interpretation of discrepancies on uranium content in samples collected at Alte Madonie Mounts region (Sicily, Italy)
2013
Abstract The main goal of this work is to evaluate a correlation between anomalous Uranium (U) content and petrographic features of some soil and rock samples collected at Alte Madonie Mounts region (North-central Sicily, Italy). A total of 41 samples of selected soils and rocks were collected, powdered, dried and sealed in “Marinelli” beakers for 20 days before the measurement to ensure that radioactive equilibrium between 226 Ra and 214 Bi was reached. Gamma-ray spectrometric analysis was used to quantify radioactivity concentrations. Mineralogical and chemical features of the samples were determined by X-ray Fluorescence (XRF), X-ray Diffractometry (XRD), Attenuated Total Reflection-Four…