Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions

2016

Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely “bicuspid aortopathy”) is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting fr…

MalePatient-Specific ModelingBicuspid aortic valveComputed Tomography AngiographyHeart Valve DiseasesBiomedical EngineeringMedicine (miscellaneous)Bioengineering—Three-dimensional anatomic reconstructionElectrocardiographyImaging Three-DimensionalBicuspid Aortic Valve DiseaseSettore ING-IND/12 - Misure Meccaniche E TermicheHumans—Finite-element analysiProspective StudiesAortaAgedRetrospective Studies—Aortic failureHemodynamicsModels CardiovascularComputational BiologySettore ING-IND/34 - Bioingegneria IndustrialeMiddle AgedBiomaterialAortic Aneurysm—Ascending thoracic aortic aneurysmAortic ValveFemaleStress MechanicalSoftware
researchProduct

Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device

2017

Abstract Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdomi…

MalePatient-Specific ModelingCardiac outputLeft ventricular assist device (LVAD)medicine.medical_treatmentHemodynamicsBlood Pressure02 engineering and technology030204 cardiovascular system & hematology0302 clinical medicineCeliac ArteryParticle image velocimetry (PIV)Phantoms ImagingAbdominal aortaModels CardiovascularEquipment DesignMiddle AgedTreatment Outcomemedicine.anatomical_structureEchocardiographyCardiologyEquipment FailureRadiologyGastrointestinal HemorrhageRheologyBlood Flow VelocityArterymedicine.medical_specialty0206 medical engineeringBiomedical EngineeringBiophysicsAnastomosis03 medical and health sciencesInternal medicinemedicine.arterySettore ING-IND/12 - Misure Meccaniche E TermichemedicineHumansAbdominal aortaGastrointestinal bleedingbusiness.industrymedicine.disease020601 biomedical engineeringTrunkEquipment Failure AnalysisBiophysicVentricular assist deviceHeart failureHeart-Assist DevicesbusinessMedical Engineering & Physics
researchProduct

Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…

2017

Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyLeft gastric arteryComputed Tomography Angiographyceliac trunkmedicine.medical_treatment0206 medical engineeringgastrointestinal bleedingHemodynamicsabdominal aorta02 engineering and technology030204 cardiovascular system & hematologyElectrocardiographycomputational fluid dynamic03 medical and health sciences0302 clinical medicineCeliac ArteryInternal medicinemedicine.arteryMultidetector Computed Tomographyleft ventricular assist deviceSettore ING-IND/12 - Misure Meccaniche E TermichemedicineHumansComputer SimulationTransplantationCommon hepatic arteryPhantoms Imagingbusiness.industryAbdominal aortaUltrasonography DopplerMiddle Agedmedicine.disease020601 biomedical engineeringTrunkOstiumVentricular assist deviceHeart failurecardiovascular systemCardiologyFemaleSurgeryHeart-Assist DevicesCardiology and Cardiovascular MedicinebusinessAlgorithmsBlood Flow VelocityThe Journal of Heart and Lung Transplantation
researchProduct

High frequency modeling technique for three phase power electronics module

2015

Nowadays, the high integrated power electronics modules (PMs), characterized by high speed, low loss and hard ware miniaturization, represent a new technology that meets the emerging demands of many applications, such us vehicle and home appliance, renewable energy sources in smart grid. The integration process and the high switching speeds increase the PM electromagnetic emissions that can create electromagnetic interference (EMI) with electric/electronic devices near the PMs. For this reason, electromagnetic compatibility (EMC) have to be carefully considered, yet in the design phase, to guarantee the reliability of PM systems. In this paper a method to develop a high frequency (HF) model…

MarketingEngineeringRenewable Energy Sustainability and the Environmentbusiness.industryElectromagnetic compatibilityEnergy Engineering and Power TechnologyPower moduleElectromagnetic interferenceElectromagnetic interferenceStrategy and Management1409 Tourism Leisure and Hospitality ManagementSmart gridEMIHigh frequency modelingPower modulePower electronicsMiniaturizationElectronic engineeringElectromagnetic compatibilityElectronicsbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT)
researchProduct

Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy

2020

GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.

Materials scienceDosimeterFoggingbusiness.industryCalibration curveSettore ING-IND/20 - Misure E Strumentazione Nuclearimedicine.medical_treatmentBrachytherapydosimetry GAFChromic film gamma radiation radiotherapy030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed dosemedicineDosimetrybusinessQuality assuranceBiomedical engineering
researchProduct

A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

2018

© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…

Materials scienceElectronic sphygmomanometerIdentification errorMulti wavelengthPeripheralInflatableBlood pressuremedicine.arteryCuffSettore ING-IND/12 - Misure Meccaniche E TermichemedicineRadial arteryblood pressure Multi-Wavelength opto-electronic patch sensor (OEPS) photopletismgraphy PPG systolic blood pressure wearable sensorBiomedical engineeringDesign and Quality for Biomedical Technologies XI
researchProduct

Simultaneous measurement of temperature and strain in glass fiber/epoxy composites by embedded fiber optic sensors: I. Cure monitoring

2007

In this paper (Part I) the use of fiber optic sensors for real-time monitoring of the cure kinetics of GFRP composites is explored. The proposed sensing system allows the simultaneous measurement of both temperature and strain by monitoring the change in reflected wavelength from two coupled fiber Bragg grating (FBG) sensors that have been embedded into the composite laminate. Instrumented GFRP laminates with 12, 18 and 24 reinforcing plies, respectively, were prepared by means of the vacuum bagging technique. Samples were cured in a thermally controlled oven at 80 degrees C and 30 kPa for 240 min (isothermal stage) and then cooled down to ambient temperature by turning off the heating sour…

Materials scienceFiber Bragg grating (FBG) sensorsComposite numberGlass fiberFiber Bragg gratingComposite cure monitoringSettore ING-IND/12 - Misure Meccaniche E TermicheSITUTemperature mesurementGeneral Materials ScienceCure monitoringElectrical and Electronic EngineeringComposite materialBRAGG GRATING SENSORSCivil and Structural EngineeringOptical fiber sensorEpoxyFibre-reinforced plasticCondensed Matter PhysicsTHERMOSETFiber Bragg grating (FBG) sensors; Optical fiber sensor; Composite cure monitoring; Strain measurement; Temperature mesurementAtomic and Molecular Physics and OpticsMechanics of MaterialsFiber optic sensorvisual_artSignal Processingvisual_art.visual_art_mediumEPOXY-RESINStrain measurementStructural health monitoringFIBRE/EPOXY COMPOSITESSYSTEM
researchProduct

Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons

2017

Abstract This article describes Electron Spin Resonance (ESR) response measurements of Kodak BioMax alanine films exposed to low-energy X-rays from a Cu-target tube operating at 20 kV. Commercial alanine detectors were used to ensure maximum reproducibility of the results, while the choice of a film was due the low penetration of the soft X-rays. X-ray energy spectra and fluences were determined with an innovative digital semiconductor detector system. These data were used to quantify the irradiation of the alanine films in terms of absorbed dose to water. The alanine films were found to present a stable response, highly linear with dose. To our knowledge, these data have not been previousl…

Materials sciencePhotonSettore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistrySynchrotron radiationElectron Spin Resonance030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineNuclear magnetic resonancelawIrradiationElectron paramagnetic resonanceInstrumentationAlanineAlanine; Electron Spin Resonance; Low energy photons; Radiation; InstrumentationDosimeterLow energy photonsRadiationAlanineSettore FIS/01 - Fisica SperimentaleLow energy photonequipment and suppliesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Semiconductor detector030220 oncology & carcinogenesisAbsorbed dose
researchProduct

Neutron ESR dosimetry through ammonium tartrate with low Gd content.

2014

This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…

Materials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumMonte Carlo methodAnalytical chemistrychemistry.chemical_elementGadoliniumRadiationRadiation Dosagelaw.inventionlawDosimetryRadiology Nuclear Medicine and imagingNeutronElectron paramagnetic resonanceRadiometryTartratesNeutronsRadiationRadiological and Ultrasound Technologyammonium tartratebusiness.industryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyResonanceGeneral MedicineESR Dosimetryneutron dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryMeasuring instrumentNuclear medicinebusinessMonte Carlo MethodRadiation protection dosimetry
researchProduct

Gamma-ray spectrometric measurement of radionuclide purity of radiopharmaceuticals contained in bottle samples

2012

The radionuclide purity of a radiopharmaceutical product is usually measured by gamma-ray spectrometry with various measurement geometries. The importance of this test is that the radionuclide impurities, if present, result in an increase in the radiation dose to the patient without contributing to diagnostic information and in some cases may also interfere with the marking molecules and affect the proper conduct of diagnostic examination. In this work, gamma-ray spectrometry is used to determine the amounts of impurities by adopting as measurement geometry the same bottle containing eluted or prepared radiopharmaceuticals. In addition to high-purity germanium semiconductor detectors, the u…

Materials sciencebusiness.product_categorySettore ING-IND/20 - Misure E Strumentazione Nucleariradionuclide purityScintillatorMass spectrometrymedicineBottlelcsh:Nuclear and particle physics. Atomic energy. RadioactivitySafety Risk Reliability and Qualitygamma-ray spetrometryRadionuclidemedicine.diagnostic_testbusiness.industryElutionRadiochemistrydoseGamma raySemiconductor detectorPETNuclear Energy and EngineeringPositron emission tomographySPECTradionuclide purity PET SPECT gamma-ray spetrometry doselcsh:QC770-798businessNuclear medicine
researchProduct