Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems
2009
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.
Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000
2009
This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …
Comparison of two different approaches for harmonic distortion sources assessment
2021
The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.
Double squirrel cage induction motors: A new approach to detect rotor bar failures
2013
The purpose of this paper is to present a diagnosis technique, for rotor broken bar in double cage induction motor, based on a combined use of frequency sliding and wavelet transform analysis, to isolate the contribution of the rotor fault components issued from vibration signals in a single frequency band. The validity of the proposed diagnosis approach is not limited to the analysis under steady-state operating conditions, but also for time-varying conditions where rotor fault components are spread in a wide frequency range.
Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
2017
Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…
LOW DOSE CHARACTERIZATION OF FRICKE GEL DOSIMETERS BY OPTICAL ABSORBANCE AND MR RELAXATION METHODS
2016
Introduction Fricke gel dosimeters allow measurements of 3D dose distributions and can be an effective tool for dosimetry verifications in radiotherapy. Various authors have reported drawbacks of the gels affecting the accuracy in case of low dose measurements. Purpose This study aims at investigating such drawbacks and at establishing the conditions for an optimal use of the gels. Materials and methods Our dosimeters consist of gels infused with a Fricke ferrous sulphate solution combined with xylenol orange (XO). Two kinds of xylenol orange (XO) and two different gelling agents (gelatin from porcine skin and Agarose) were utilized. Gels are red out by light absorption techniques: images o…
IEEE Std 1459–2010. IEEE Standard Definitions for the Measurement of Electric Power Quantities under Sinusoidal, Nonsinusoidal, Balanced or Unbalance…
2010
Definitions used for measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions are provided in this standard. Mathematical expressions that were used in the past, as well as new expressions, are listed, as well as explanations of the features of the new definitions.
PQ Metrics Implementation on Low Cost Smart Metering Platforms. A Case Study Analysis
2018
The increasing interest on the quality of the energy supplied and generated in distribution networks is raising the need of distributed power quality (PQ) measurements. To allow such capabilities with cost effective metering solutions, this paper wants to investigate the feasibility of using smart meters, already installed for energy billing, also for power quality monitoring. To this aim, an electronic board (based on STCOMET metrology device), already used in many energy meters of different countries, has been selected as case study platform. The manufacturer firmware of this board was essentially aimed at implementing energy meter metrics and power line communications functionalities. In…
Measurement of 210Pb airborne activity concentration by gamma-ray spectrometry of air particulate samplings
2009
Lead-210 (half-life 22.3 y), is a natural radionuclide, being produced in the atmosphere through radon decay. Due to its affinity for particles, it is rapidly fixed by aerosols and, with its long half-life is the most important tracer of long range atmospheric aerosol transport and removal processes. Main measurement techniques adopted to evaluate 210Pb air activity concentration differ in analysis and sample preparation methods. Some of them involved complex chemical processes or decay product detection (for example 210Po), with a long decay time period between sampling and experimental measurement. The availability of an high-volume particulate sampler (about 900 m3 h-1) combined with a l…