Search results for " misure"
showing 10 items of 421 documents
Il metodo PUMA per la stima dell’incertezza
2009
Measurement of activity of the predominant gamma-emitting radionuclides in activated components of a medical cyclotron plan
2008
An identification and activity evaluation of the predominant gamma-emitting radionuclides in activated parts of a medical cyclotron plant by high resolution gamma-ray spectrometry were performed. The use of LaBr3:Ce scintillation and HPGe detectors was examined in order to solve the measurement problems due to high activity of some components used inside a plant provided with an IBA CYCLONE 18/9 cyclotron. For each component, the identification of some key-radionuclides allows to evaluate the surface dose behaviour as function of decay time. The largest activity values are related to radionuclides with half-life of 70-80 days, while radionuclides with higher half-lives represent less than 1…
Study of the response of phenol compounds exposed to thermal neutrons beams for Electron Paramagnetic Resonance dosimetry
2015
Abstract This paper reports the results regarding a new organic compound (IRGANOX ® 1076 phenols) with and without low content (5% by weight) of gadolinium oxide (Gd 2 O 3 ) for Electron Paramagnetic Resonance (EPR) dosimetry of neutron beams. The dependence of EPR signal as function of neutron dose was investigated in the fluence range studied between 10 11 cm −2 to 10 14 cm −2 . We evaluated also the effect of gadolinium on 60 Co gamma photon sensitivity of this organic compound. Our analysis showed that a low concentration of gadolinium oxide (of the order of 5% of the total mass of the dosimeter) can enhance the thermal neutron sensitivity more than 10 times with a small reduction of …
Metrological performances of voltage and current instrument transformers in harmonics measurements
2018
In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…
Current transformers effects on the measurement of harmonic active power in LV and MV networks
2011
The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …
Donne autrici o vittime di reato? Un’indagine sull’efficacia delle misure alternative nei percorsi di recupero delle detenute nel contesto agrigentino
2015
Nel senso comune la pena detentiva e considerata un elemento inevitabile della so¬cieta contemporanea. Essa continua ad essere percepita nell’immaginario collettivo come uno strumento di segregazione per coloro che sono riconosciuti colpevoli di particolari reati. I principi classici della prontezza, proporzionalita, infallibilita e dolcezza della pena non si identificano oggi esclusivamente con un edificio – la prigione – ma, sempre piu di frequente, con strumenti alternativi e piu efficaci per il recupero e la risocializzazione del soggetto. Proprio in questi decenni in cui l’intreccio fra poverta, penalita ed esclusione sociale diviene sempre piu evidente, l’afflizione a cui il singolo e…
Uncertainty management in the measurements of low frequency magnetic fields
2014
The paper deals with low-frequency magnetic field measurements carried out by using a broadband and isotropic instrument. These measurements are characterized by very high uncertainty values, which imply a high risk of wrong decisions when there is the need to establish if a site complies or does not comply with specified emission limits. To reduce this risk, we decided to perform the so called “uncertainty management” that is the discipline of optimizing the cost of a measurement versus the uncertainty target. The task is achieved by using the PUMA method that is an iterative technique originally conceived for geometrical and mechanical measurements. The approach is completely based on the…
UNCERTAINTY EVALUATION IN THE LOW-FREQUENCY MAGNETIC FIELD MEASUREMENTS WITH REGARD TO EXPOSURE OF HUMAN BEINGS
2010
The paper deals with low-frequency magnetic field measurements, with regard to exposure of human beings, carried out by using a broadband and isotropic instrument. These measurements are characterized by a very high uncertainty values if compared with the ones usually related to other electrical measurements. These large uncertainty values imply a high risk of wrong decision when there is the need to establish if a site complies or does not comply with a specified emission limits. A reduction of the uncertainty values implies a reduction of the risk. With this aim, in the paper we propose an approach which, in case of fields generated by electric power systems (50 or 60 Hz), allows an effec…
A Monte Carlo-aided design of a modular 241Am-Be neutron irradiator
2013
Monte Carlo studies aimed at designing a modular 241Am-Be neutron irradiator for testing neutron detectors and personal dosimeters and processing large volume samples are reported in this study. The evaluation of the shapes and thicknesses of the moderator and shielding materials was carried out by a MCNP5 Monte Carlo simulation code. The reliability of the simulation was experimentally verified by the activation of gold foils and TLD dosimeter measurements in an irradiation cell placed at the center of the test configuration.
DEVELOPMENT AND CHARACTERIZATION OF ADVANCED METERING AND ICT SOLUTIONS FOR SMART ENERGY DISTRICTS
2022
Climate change will have an influence on the world's 8 billion inhabitants, the majority of whom live in cities, which account for roughly two-thirds of the CO2 emissions that are at the root of the climate crisis. To attain a net-zero carbon future, a rapid transition across business models and policy is required. At the same time, policy and legislation are struggling to keep up with smart technology and the Internet of Things. The management of smart urban infrastructure is the key to successful decarbonisation and the achievement of sustainable cities. In this framework, the smart electricity infrastructure shall be equipped with integrated technologies, such solar panels, storage facil…