Search results for " misure"

showing 10 items of 421 documents

A resilient distributed measurement system for smart grid application

2020

Since the production of energy from renewable energy sources is strongly increasing, the migration from the classical electric grid toward the smart grid is becoming a reality. Distribution System Operators, along with the control of the entire network and its stability, need to address the security and the reliability of the communication channels and the data itself. In this paper a solution is proposed to address these issues. It is based on a distributed measurement system that relies on a wireless network as well as a redundant Power Line communication system in order to transfer the electrical measures to a centralized SCADA server. The collected data are used to run a power flow algo…

Distributed measurement systemsWireless networkbusiness.industryComputer scienceReliability (computer networking)Distributed computingSmart gridGridelectric load flowHuman-machine interfaceslaw.inventionPower-line communicationSmart gridSCADAlawElectrical networknetwork securityElectricitySCADAbusinesscarrier transmission on power linesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

An Innovative dosimeter based on a floating Gate sensor

2019

This work describes the development of a new method for recording radiation exposure by using a passive dosimeter based on a Floating Gate CMOS sensor. The floating Gate sensors based on the MOS structure discharge allow the construction of compact and cost-efficient dosimeters, realized in VLSI CMOS technology, for use in integration mode in various applications, in particular in radiotherapy.

Dosimeter photons Floating Gate CMOSSettore ING-IND/20 - Misure E Strumentazione Nucleari
researchProduct

Studio di modelli equivalenti per la simulazione con il codice PENELOPE della risposta in efficienza di un rivelatore HPGe

2017

La simulazione della risposta di un rivelatore HPGe con l’impiego di codici Monte Carlo è una tecnica ormai diffusamente impiegata e particolarmente utile per la valutazione di efficienze quando non sono disponibili standards di calibrazione con stessa forma e composizione del campione in esame. Il risultato della simulazione dipende dalla conoscenza più o meno dettagliata delle caratteristiche del rivelatore, atte a definire un “modello” dello stesso. Per evidenziare anche quelle parti non definite nella certificazione del costruttore, solitamente si effettua una radiografia del rivelatore fatta eccezione per i casi in cui non è realizzabile pena lo smontaggio della struttura di schermatur…

Efficienza Monte Carlo Rivelatori HPGeSettore ING-IND/20 - Misure E Strumentazione Nucleari
researchProduct

PV Reconfiguration Systems: a Technical and Economic Study

2017

Dynamical electrical array reconfiguration strategies for grid-connected PV systems have been proposed as solution to improve energy production due to the mismatch effect of PV plants during partial shading conditions. Strategies are based on the use of dynamic connections between PV panels given by the employment of switches that allow for each panel the series, parallel or exclusion connections, physically changing the electrical connections between the related PV modules, consequentially modifying the layout of the plant. Usually the cost of the dynamic matrix is not taken into account. This novel work evaluates the economic advantages obtained by the use of reconfiguration strategies in…

Electrical connectionPhotovoltaic; Renewable energy sources; Economic advantages; Electrical connection; Energy productions; European Countries; Grid connected PV system; Photovoltaic; Reconfiguration system; Renewable energy sourceRenewable energy sourceGrid connected PV systemEconomic advantageSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSettore ING-IND/31 - ElettrotecnicaEnergy productionEuropean Countrielcsh:Electrical engineering. Electronics. Nuclear engineeringrenewable energy sourcesSettore ING-INF/07 - Misure Elettriche E ElettronichePhotovoltaiclcsh:TK1-9971Reconfiguration systemJournal of Electrical Systems
researchProduct

Realizzazione in ambiente LabVIEW di un sistema automatico di gestione della cella GTEM per prove di compatibilità elettromagnetica

2010

Electromagnetic Compatibility GTEM Cell Radiated EmissionsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Strumento virtuale in ambiente LabVIEW per la gestione automatica di misure di emissione radiata in camera semianecoica

2010

Electromagnetic Compatibility Semi-Anechoic Chamber Radiated EmissionsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Measurements methodology for the reliability evaluation of intelligent power modules

2014

The paper describes a measurement methodology for the reliability evaluation of new intelligent power electronics modules (IPMs). In particular, the evaluation of the IPMs immunity to radio frequency conducted disturbances has been performed, at different operating thermal conditions, designing a suitable measurement set up in a shielded room. Moreover, the thermal performances of the devices have been analyzed, setting up a proper experimental test bench. The measurements procedures are detailed described. © 2014 IEEE.

Electromagnetic compatibility (EMC)Engineeringbusiness.industryPower moduleEMCintegrated power electronic modulesControl engineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettronicheelectrothermal effectReliability (statistics)Reliability engineering
researchProduct

Electron paramagnetic resonance line shape investigation of the Si-29 hyperfine doublet of the E'γ center in a-SiO2

2007

We report an experimental study by electron paramagnetic resonance (EPR) spectroscopy of the E′γ center and of its hyperfine structure, consisting in a pair of lines split by 42 mT. Our results show that two types of E′γ centers can be distinguished on the basis of the EPR line shapes of their main resonance line and hyperfine structure. (© 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

Electron nuclear double resonanceChemistrySettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleCenter (category theory)radiazione gammaCondensed Matter Physicslaw.inventionNuclear magnetic resonanceelectron paramagnetic resonancelawAtomic physicsSpectroscopyElectron paramagnetic resonanceResonance lineHyperfine structureLine (formation)
researchProduct

Electron paramagnetic resonance investigation on the hyperfine structure of the center in amorphous silicon dioxide

2007

Abstract We report an experimental investigation by electron paramagnetic resonance (EPR) spectroscopy on the hyperfine structure of the E δ ′ center in γ-ray irradiated amorphous silicon dioxide materials. This study has driven us to the determination of the intensity ratio between the hyperfine doublet and the main resonance line of this point defect. This ratio was obtained for a variety of silica samples and compared with the analogous ratio obtained for the E γ ′ defect. The comparison definitively confirms that the electronic wave function involved in the E δ ′ center is actually delocalized over four nearly equivalent Si atoms.

Electron nuclear double resonanceSettore ING-IND/20 - Misure E Strumentazione NucleariChemistrySettore FIS/01 - Fisica SperimentaleSilica Electron spin resonance DefectsAnalytical chemistryCondensed Matter PhysicsCrystallographic defectElectronic Optical and Magnetic Materialslaw.inventionDelocalized electronlawMaterials ChemistryCeramics and CompositesIrradiationAtomic physicsElectron paramagnetic resonanceWave functionSpectroscopyHyperfine structureJournal of Non-Crystalline Solids
researchProduct

Study, project and implementation of new metrics for distributed measurement system in medium voltage smart grid

2022

Energy Management SystemIEEE 1459-2010Arc faultPower qualityenergy storage system batteryUL 1699Bsmart gridBattery Management Systemrenewable energySettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct