Search results for " phantom"

showing 10 items of 138 documents

Influence of pixel size on quantification of airway wall thickness in computed tomography.

2009

Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …

Pixelmedicine.diagnostic_testbusiness.industryPhantoms ImagingComputed tomographyField of viewBronchiBronchographycomputer.software_genreImaging phantomRadiographic Image EnhancementFull width at half maximumVoxelApproximation errorComputer GraphicsMedicineHumansRadiographic Image Interpretation Computer-AssistedRadiology Nuclear Medicine and imagingbusinessNuclear medicineTomography X-Ray ComputedImage resolutioncomputerSoftwareJournal of computer assisted tomography
researchProduct

Active contour algorithm with discriminant analysis for delineating tumors in positron emission tomography.

2019

Abstract In the context of cancer delineation using positron emission tomography datasets, we present an innovative approach which purpose is to tackle the real-time, three-dimensional segmentation task in a full, or at least nearly full automatized way. The approach comprises a preliminary initialization phase where the user highlights a region of interest around the cancer on just one slice of the tomographic dataset. The algorithm takes care of identifying an optimal and user-independent region of interest around the anomalous tissue and located on the slice containing the highest standardized uptake value so to start the successive segmentation task. The three-dimensional volume is then…

Positron emission tomographyComputer scienceInitializationMedicine (miscellaneous)Context (language use)Imaging phantomActive contour algorithm03 medical and health sciences0302 clinical medicineRegion of interestArtificial IntelligenceNeoplasmsmedicineHumansSegmentation030304 developmental biologyRetrospective Studies0303 health sciencesActive contour modelDiscriminant analysimedicine.diagnostic_testbusiness.industryDiscriminant AnalysisPattern recognitionLinear discriminant analysisPositron emission tomographyBiological target volume segmentationPositron-Emission TomographyArtificial intelligencebusiness030217 neurology & neurosurgeryAlgorithmsArtificial intelligence in medicine
researchProduct

Phantom iterates of continuous functions

1985

Pure mathematicsComposition operatorIterated functionCommutative algebraImaging phantomMathematicsIteration theory
researchProduct

Evaluation of DR and CR digital mammography systems based on phantom and breast dosimetry.

2006

Digital mammography has been progressively introduced in screening centers, since recent evolution of CR and DR detectors. However, it is questionable which exposure conditions would be more suitable when these techniques are applied, in order to reduce the glandular breast doses, as they are related with induced carcinogenesis. Several exposures have been performed in CR and DR mammography units for comparing absorbed doses during quality control assessments and during screening, diagnosis and treatment. In the first case, the CIRS11A mammographic phantom has been used with standard exposure conditions (28 kV, AEC mode with blackening +0, 50:50 glandularity and 4.5 compressed breast thickn…

Quality Controlmedicine.medical_specialtyDigital mammographyImage qualityBreast NeoplasmsRadiation DosageImaging phantommedicineMammographyDosimetryHumansMedical physicsRadiometrymedicine.diagnostic_testbusiness.industryComputersPhantoms ImagingEquipment DesignRadiographic Image EnhancementClinical diagnosisReference valuesRadiographic Image EnhancementFemaleNuclear medicinebusinessSoftwareMammographyConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
researchProduct

Monte Carlo dosimetric study of the medium dose rate CSM40 source

2013

Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…

RadiationPhotonPhantoms Imagingbusiness.industryChemistryRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentMonte Carlo methodBrachytherapyWaterRadiotherapy DosageImaging phantomComputational physicsKermaCesium RadioisotopesAbsorbed dosemedicineAnisotropyHumansRadiometryNuclear medicinebusinessRadiation treatment planningMonte Carlo MethodUncertainty analysisApplied Radiation and Isotopes
researchProduct

End-to-end tests using alanine dosimetry in scanned proton beams

2018

This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…

Radiology Nuclear Medicine and ImagingMaterials sciencePelviMonte Carlo methodanthropomorphic phantomauditRadiation DosageImaging phantom030218 nuclear medicine & medical imaginglaw.inventionPelvisSynchrotron03 medical and health sciences0302 clinical medicinelawIonizationend to end testDosimetryHumansPencil-beam scanningRadiometryAlaninedosimetryRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-Assistedequipment and suppliesSynchrotron030220 oncology & carcinogenesisIonization chamberProtonProtonsHeadMonte Carlo MethodBeam (structure)SynchrotronsBiomedical engineeringHuman
researchProduct

Image-based MRI Gradient Estimation

2017

In order to reduce geometric distortion phenomena in MR images, every MRI system main magnet undergoes a shimming process. Since this process aims at optimizing magnetic field homogeneity within a so-called uniformity sphere, image quality outside this sphere is neglected. Since the fields vary smoothly in space, MR signal-to-noise ratio is still non-zero just outside the uniformity region, but correction of MR image distortion fails due to lack of magnetic field knowledge outside it. We propose a novel algorithm for measuring all the fields involved in the generation of images. Our proposal is based on exploitation of the distortion which can be observed in images of a known phantom. The p…

RegistrationImage qualityComputer scienceBiomedical EngineeringBiophysicsImage enhancement/restoration (noise and artifact reduction)Signal-To-Noise Ratio01 natural sciencesGeometric distortionImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine0103 physical sciencesHomogeneity (physics)Gradient estimationRadiology Nuclear Medicine and imagingComputer visionMagnetic resonance imaging (MRI)010306 general physicsPhantoms Imagingbusiness.industrySettore ING-INF/03 - TelecomunicazioniImage EnhancementMagnetic Resonance ImagingMagnetic fieldMagnetArtificial intelligencebusinessAlgorithmsImage based
researchProduct

SU-FF-T-62: Dosimetric Evaluation of An Internal Shielding Used with a HDR Skin Applicator

2009

Purpose: The Valencia HDR skin applicators are accessories of the microSelectron HDR afterloading system (Nucletron) cup shaped to limit the dose to the irradiation area. Applicators sizes are: diameter 2 and 3 cm. The typical prescription depth is 3 mm. This work aims to evaluate the backscatter and electron contamination of an internal shielding used to reduce the dose to the ocular globe when the lesion is located at the eyelid. Monte Carlo(MC) and experimental methods have been used. Method and Materials: The geometry has been: the Valencia applicator (2 cm diameter) on the surface of a solid polystyrene slab phantom; inside, a 2 mm lead slab located at 3 mm depth. MC simulation charact…

ScannerLead shieldingOpticsMaterials sciencebusiness.industryAbsorbed doseElectromagnetic shieldingMonte Carlo methodDosimetryGeneral MedicinebusinessBolus (radiation therapy)Imaging phantomMedical Physics
researchProduct

34. Accomplishing the requirements within the new decree 159/2016: Comparative study of eddy currents induced in a human phantom moving near differen…

2018

Purpose In order to provide adequate risk-reducing procedures for MRI personnel (radiographers, anaesthetists, physicists, nurses, technicians, cleaners, etc.), different studies have been developed in the past years. Further to those, in the present work risk assessment concerned with currents induced by non-uniform static magnetic fields in MRI operators performing different tasks in proximity of the scanner has been investigated across a set of different 1.5 T MRI scanners. Methods The first step has been to empirically map the magnetic field around the different scanners and to select a proper adult human body as a heterogeneous volume conductor model. Then, upon observing the way tasks…

ScannerPhysiological significanceComputer scienceWork (physics)BiophysicsGeneral Physics and AstronomyGeneral MedicineImaging phantomlaw.inventionlawEddy currentRadiology Nuclear Medicine and imagingSet (psychology)SimulationPhysica Medica
researchProduct

Metodi Automatici per la Compensazione della Distorsione in Immagini di Risonanza Magnetica

Settore ING-INF/03 - TelecomunicazioniGeometric DistortionSpherical HarmonicMRI PhantomMRI; Geometric Distortion; Spherical Harmonics; MRI Phantom;MRI
researchProduct