Search results for " photovoltaic"
showing 10 items of 242 documents
A simple and accurate model of photovoltaic modules for power system design
2014
Review of the energy and economic parameters involved in the effectiveness of grid-connected PV systems installed in multi-storey buildings
2014
Abstract The assessment of PV energy in an urban context is extremely complex because many factors have to be considered. Moreover, when the purpose is calculating the realistic amount of the electricity demand of a city that can be covered by the photovoltaic generation, it is necessary to estimate the number of photovoltaic systems whose installation is economically advantageous. Such a topic requires an economic analysis, which is affected by the number of energy and economic parameters involved and the values assigned to them to perform calculations. Some parameters are perfectly known and unvarying, like the paid incentives. Adversely, some parameters, like the efficiency degradation o…
PV systems in the vertical walls: A comparison of innovative structures
2016
This paper presents the performance comparison of PV windows with the purpose of tracing the behavior of next-generation systems, which could favor architectonical integration. More in detail, a dye sensitized solar cell (DSSC) and blue and grey thin film silicon panels have been analyzed. The systems can be placed behind a window or behind a wall of glass blocks. The three generation systems are then compared in terms of both efficiency and Fill Factor.
Review on photovoltaic based active generator
2015
An active generator has the capacity to support frequency control and instantaneous power balance. The grid operator adjusts the power dispatch of generators according to power demand fluctuations. Photovoltaic (PV) based active generators can be used as load following generators in the same manner as other power dispatch generators. This new type of distribution system, based on active generator(s), needs new innovative management and operation strategies for increasing the penetration of intermittent renewable energy systems. The considered PV based active generator has three units, i.e., PV array, battery storage and super capacitor. In this review paper, the management and operation app…
Techno-economic optimum sizing of hybrid renewable energy system
2013
Using off grid hybrid renewable energy systems for rural electrification has become an attractive solution for those areas, where grid electricity is not feasible or cost of the grid extension is relatively large. Hybrid system combines several energy systems together, therefore it can supply high reliable electricity rather than a PV/battery system or a wind/battery system. But the most important thing is that the system should be economically attractive. To achieve both of these features, each of the components in the hybrid system should be optimally sized. This requires a detailed techno-economic analysis of different possible hybrid system configurations. The objective of this study is…
Comparison of power quality impact of different photovoltaic inverters- the viewpoint of the grid
2005
This paper presents the results of an experimental analysis performed with the aim of evaluating the effect of many photovoltaic plants on power quality of the grid. Several parameters as voltage and current distortion, flicker, voltage variations at fundamental frequency and power factor have been observed. The measured values have been compared with the limits reported in the standards and, when possibiIe, their dependence on the characteristics of the grid in terms of its impedance has been pointed out.
Charging management of grid integrated battery for overcoming the intermittency of RE sources
2016
Grid integration of distributed generation (DG) systems with energy storage system can help not only in increasing the more penetration of DG systems into the network but it is also going to help in improving the power system dynamics, stability and control as well as helping in demand side management. In this work, a method for integrating an energy storage with the grid which can provide the prescribed active and reactive power to the grid is presented. The main objective is to ensure a high state of charge (SOC) of the battery with the innovative control system for taking part in power system control. Active and reactive power dispatching using a bi-directional DC-DC converters and a vol…
Harmonic mitigation of a grid-connected photovoltaic system using shunt active filter
2017
Conventional LC filters cannot compensate effectively harmonics due to non-linear loads in a grid-connected photovoltaic (PV) system. Thus, active power filters (APF) are introduced due to its characteristics and performances, for compensation of harmonics from non-linear loads in the grid-connected photovoltaic (PV) system. This work presents a three-phase voltage-fed shunt active power filter implementation to mitigate the harmonics in which the filter control system focuses on generating reference source current for compensating harmonic effects from non-linear loads. Furthermore, the developed model is verified with an experimental data from a nonlinear load.
A mathematical model to determine the electrical energy production in photovoltaic fields under mismatch effect
2009
Among the electrical energy production systems from renewable sources, the photovoltaic one represents today one of the most efficient and technically tested choice. In this paper the authors present a mathematical model that allows the maximization of the generated power of photovoltaic (PV) plants under unequally radiation conditions. In particular, thanks to the model of a PV plant, unequally radiated, developed in Matlab-Simulink environment, in this paper the mismatch problem of PV plants is dealt with. The simulations curried out allow to assert that by putting into action re-configuration techniques of series-parallel connections of PV plants, under unequally radiation, can allow to …
Electrical-optical characterization of multijunction solar cells under 2000X concentration
2014
In the framework of the FAE "Fotovoltaico ad Alta Efficienza" ("High Efficiency Photovoltaic") Research Project (PO FESR Sicilia 2007/2013 4.1.1.1), we have performed electrical and optical characterizations of commercial InGaP/InGaAs/Ge triple-junction solar cells (1 cm2) mounted on a prototype HCPV module, installed in Palermo (Italy). This system uses a reflective optics based on rectangular off-axis parabolic mirror with aperture 45×45 cm2 leading to a geometrical concentration ratio of 2025. In this study, we report the I-V curve measured under incident power of about 700 W/m2 resulting in an electrical power at maximum point (PMP) of 41.4 W. We also investigated the optical properties…