Search results for " platform"
showing 10 items of 411 documents
A new method to calculate external mechanical work using force-platform data in ecological situations in humans: Application to Parkinson's disease
2016
Abstract Background and aim To accurately quantify the cost of physical activity and to evaluate the different components of energy expenditure in humans, it is necessary to evaluate external mechanical work ( W EXT ). Large platform systems surpass other currently used techniques. Here, we describe a calculation method for force-platforms to calculate long-term W EXT . Methods Each force-platform (2.46 × 1.60 m and 3.80 × 2.48 m) rests on 4 piezoelectric sensors. During long periods of recording, a drift in the speed of displacement of the center of mass (necessary to calculate W EXT ) is generated. To suppress this drift, wavelet decomposition is used to low-pass filter the source signal.…
Effects of muscle – tendon length on joint moment and power during sprint starts
2005
The aim of this study was to examine the effects of muscle-tendon length on joint moment and power during maximal sprint starts. Nine male sprinters performed maximal sprint starts from the blocks that were adjusted either to 40 degrees or 65 degrees to the horizontal. Ground reaction forces were recorded at 833 Hz using a force platform and kinematic data were recorded at 200 Hz with a film camera. Joint moments and powers were analysed using kinematic and kinetic data. Muscle - tendon lengths of the medial gastrocnemius, soleus, vastus medialis, rectus femoris and biceps femoris were calculated from the set position to the end of the first single leg contact. The results indicated that bl…
Anticipatory strategies of team-handball goalkeepers
2011
This study seeks to discover whether handball goalkeepers employ a general anticipatory strategy when facing long distance throws and the effect of uncertainty on these strategies. Seven goalkeepers and four throwers took part. We used a force platform to analyse the goalkeeper's movements on the basis of reaction forces and two video cameras synchronised at 500 Hz to film the throw using 3D video techniques. The goalkeepers initiated their movement towards the side of the throw 193 ± 67 ms before the release of the ball and when the uncertainty was reduced the time increased to 349 ± 71 ms. The kinematics analysis of their centre of mass indicated that there was an anticipatory strategy of…
One-year persistence of individual gait patterns identified in a follow-up study – A call for individualised diagnose and therapy
2017
Abstract Although a hunch about the individuality of human movements generally exists, differences in gait patterns between individuals are often neglected. To date, only a few studies distinguished individual gait patterns in terms of uniqueness and emphasised the relevance of individualised diagnoses and therapy. However, small sample sizes have been a limitation on identifying subjects based on gait patterns, and little is known about the permanence of subject-specific characteristics over time. The purpose of this study was (1) to prove the uniqueness of individual gait patterns within a larger sample and (2) to prove the long-term permanence of individual gait patterns. A sample of 128…
Bipedal distribution of human vestibular‐evoked postural responses during asymmetrical standing
2002
Galvanic vestibular stimulation (GVS) evokes responses in muscles of both legs when bilateral stimuli are applied during normal stance. We have used this technique to assess whether asymmetrical standing alters the distribution of responses in the two legs. Subjects stood either asymmetrically with 75% of their body weight on one leg or symmetrically with each leg taking 50% of their body weight. The net response in each leg was taken from changes in ground reaction force measured from separate force plates under each foot. The net force profile consisted of a small initial force change that peaked at approximately 200 ms followed by an oppositely directed larger component that peaked at ap…
Reaction time and electromyographic activity during a sprint start.
1990
Eight male sprinters were filmed running three maximal starts over 3 m on a long force platform. The subjects were divided into two groups (n = 4) according to the leg on which the electromyograph (EMG) electrodes were fixed. When in the set position one group had electrodes on the front leg (FLG) and the other group on the rear leg (RLG). The EMG activities of the gastrocnemius caput laterale muscle (GA), vastus lateralis muscle (VL), biceps femoris caput longum muscle (BF), rectus femoris muscle (RF) and gluteus maximus muscle (GM) were recorded telemetrically using surface electrodes. Total reaction time (TRT) was defined as the time from the gun signal until a horizontal force was produ…
Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.
1986
The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…
Postural stability in subjects with whiplash injury symptoms: results of a pilot study
2014
Posturographic tests can be used to assess and confirm the body's imbalance in subjects with whiplash injury. Further studies with larger cohorts are necessary to confirm this pilot study.To verify through a posturographic exam the qualitative and quantitative alterations of postural stability in subjects with previous cervical trauma in comparison with healthy subjects.A total of 42 subjects were analysed for the study; 22 as the control group (NM) and 20 (WM) with a positive anamnesis of whiplash injury from 3 to 12 month from diagnosis through a force platform. Centre of pressure (CoP) movements of the two groups with their eyes open and closed were recorded.During the closed eye test, t…
Biomechanical and skeletal muscle determinants of maximum running speed with aging.
2009
Purpose: Aging diminishes the ability to run fast, but the specific mechanisms responsible for this deterioration remain largely unknown. In the present study, we investigated the age-related decline in sprint running ability through a cross-sectional examination of biomechanical and skeletal muscle characteristics in 77 competitive male sprinters aged 17-82 yr. Methods: Ground reaction force (GRF) and kinematic stride cycle parameters were measured during the maximum-velocity phase using a 9.4-m-long force platform. Knee extensor (KE) and ankle plantar flexor (PF) structural characteristics were investigated using ultrasonography and muscle biopsies (vastus lateralis). Force production cha…
A telemedicine platform to improve clinical parameters in paranoid schizophrenia patients: Results of a one-year randomized study
2018
Objective The study objective was to test a smartphone-based MONEO platform designed to improve the clinical condition of paranoid schizophrenia patients. Telemedicine treatment is considered to be as effective as traditional treatment in outpatient clinics. Method A total of 290 patients with paranoid schizophrenia in the symptomatic remission state were recruited to this 12-month multicenter, open-label randomized trial. A study group (n = 191) received a smartphone with the MONEO platform installed. Patients conducted cognitive training twice a week. Patients' mental state was assessed every month via teleconference. A placebo group (n = 99) received a platform with functionality limited…