Search results for " power distribution"
showing 10 items of 47 documents
Optimal Electrical Distribution Systems Reinforcement Planning Using Gas Micro Turbines by Dynamic Ant Colony Search Algorithm
2007
Distribution systems management is becoming an increasingly complicated issue due to the introduction of new energy trading strategies and new technologies. In this paper, an optimal reinforcement strategy to provide reliable and economic service to customers in a given time frame is investigated. In the new deregulated energy market and considering the incentives coming from the political and economical fields, it is reasonable to consider distributed generation (DG) as a viable option for systems reinforcement. In the paper, the DG technology is considered as a possible solution for distribution systems capacity problems, along several years. Therefore, compound solutions comprising the i…
Distraplan: a flexible tool for strategical planning of electrical distribution systems considering distributed generation.
2005
The paper here presented describes and shows DISTRAPLAN (Distribution Strategical Planning), software tool for strategical planning of distribu tion networks at Medium and Low voltage. The software aims at the identification and comparison of network configur ations, optimized in the long term with identification of special features in relation to the main technical-economical-environmental aspects, such as: the number of HV/MV and MV/LV substations, total length of the MV and LV lines and relevant sections, maximum required energy and power, instal lation and losses costs, etc. DISTRAPLAN, in both the main procedures into which it is articulated (strategical planning and evaluation of the …
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Technical, Environmental and Economical Aspects of Hybrid Systems Including Renewables and Fuel Cells
2006
In this paper, some configurations including renewables and fuel cells are studied. Technical, environmental and economical aspects are treated in the frame of the EU regulations concerning the ‘emission trading’ issue and the way in which Italy has implemented the relevant EU directive. The study has been carried out considering some architectures including renewables such as photovoltaic and wind with a back up system to increase continuity of supply based on the application of fuel cells and of a hydrogen storage system. Performing several runs with different values of the cost of energy (COE) bought from the network and produced with traditional fuel, it has been observed that, for some…
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
ATLAS technical coordination expert system
2019
When planning an intervention on a complex experiment like ATLAS, the detailed knowledge of the system under intervention and of the interconnection with all the other systems is mandatory. In order to improve the understanding of the parties involved in an intervention, a rule-based expert system has been developed. On the one hand this helps to recognise dependencies that are not always evident and on the other hand it facilitates communication between experts with different backgrounds by translating between vocabularies of specific domains. To simulate an event this tool combines information from different areas such as detector control (DCS) and safety (DSS) systems, gas, cooling, vent…
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
Improving the energy efficiency of an islanded distribution network using classical and innovative computation methods
2016
The paper presents the analysis of some potentially suitable actions for reducing the energy losses of an islanded Medium Voltage distribution network, with the aim of improving electricity distribution efficiency. For this purpose, four actions are considered: 1) increasing the network's rated voltage; 2) reactive power compensation through static capacitor banks; 3) reactive power compensation through switchable capacitor banks; 4) installation of distributed photovoltaic (PV) generation. The first two measures are typically taken into account by the distribution system operators and can be examined by means of classical design methods, whereas the latter two more innovative actions are t…
Analysis of spectral irradiance distribution for PV applications at high latitude
2020
The spectral distribution of global tilted irradiance measured in Grimstad, Norway, is analyzed in terms of the average photon energy ( $APE$ ) blue fraction ( $BF$ ) and useful fraction ( $UF$ ). The results based on eight months of recorded data show a general shift of the $APE,\ BF$ , and $UF$ values to higher values than reference AM1.5G spectrum, with 1.63 eV, 0.45, and 0.88 being the average indices, respectively. The statistical coefficient of variation ( $CV$ ) is used to determine the variation of indices. The $CV$ for $APE,\ BF$ , and $UF$ are calculated to be 20.1%, 26.1%, and 25.7%, respectively confirming the earlier findings on $APE$ being a more accurate index for the quantif…