Search results for " power system"
showing 10 items of 277 documents
Technical-economical evaluation for distributed storage applications. An Italian case study for a medium-scale public facility
2014
Time-of-use energy cost management involves the use of storage by customers to reduce their electricity bills. This can be accomplished by charging the storage during off-peak time periods, when electricity energy prices are low, and discharging it during times when on-peak energy prices are applied. This article addresses the question whether it is economically viable to install medium-scale distributed storage devices in the power system designed to lower the electricity cost for a customer-side application, assuming flexible electricity tariffs. The technical/economical evaluation is carried out referring to Lithium ion (Li-ion), Sodium Sulphur (NaS) and Vanadium Redox Battery (VRB) tech…
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
A bottom-up approach for the evaluation of the flexible quota of aggregated loads
2015
The paper presents a bottom-up approach for building the aggregated load profile of numerous passive/active users connected to the low voltage electrical system. The approach is based on the Monte Carlo method and on the knowledge of the single electric and thermal loads, generators and thermal and geometrical characteristics of the building of the single end-user. The method proposed is able to differentiate the quota of flexible and not flexible aggregate load.
Fault Tolerant Ancillary Function of Power Converters in Distributed Generation Power System within a Microgrid Structure
2013
Distributed generation (DG) is deeply changing the existing distribution networks which become very sophisticated and complex incorporating both active and passive equipment. The simplification of their management can be obtained assuming a structure with small networks, namely, microgrids, reproducing, in a smaller scale, the structure of large networks including production, transmission, and distribution of the electrical energy. Power converters in distributed generation systems carry on some different ancillary functions as, for example, grid synchronization, islanding detection, fault ride through, and so on. In view of an optimal utilization of the generated electrical power, fault to…
Control and power management of Photovoltaic-battery based micro grid
2016
The growing demand for electrical power and the interruption of the power supply has paved the way for the realization of renewable based energy generation. This paper presents the control and power management of a hybrid microgrid system that comprises Photovoltaic (PV) array, battery, and local AC load, connected to the utility grid. This work focuses on the compensation of PV power reduction due to partial shading using bidirectional half bridge converter with battery storage. This system considers fulfilling the local load demand through PV production and, then, to manage the power among the battery and grid. In the proposed system, the considered power conditioning devices area boost c…
Transient stability analysis for symmetrical and unsymmetrical faults in mixed three-phase and six-phase power systems
1989
Abstract The aim of this paper is to analyse the transient stability of a three-phase power system with six-phase lines interconnected by three-phase to six-phase transformers. For these mixed power systems a transient stability analysis is performed under all main types of disturbances (short-circuits, generator and load rejection, line outages), particularly in the case of faults at six-phase buses. A generalized procedure to evaluate transient stability is explained in detail. It is based on the symmetrical components method, which allows one to consider also unsymmetrical faults both at three-phase and six-phase buses. For every possible unsymmetrical short-circuit an equivalent fault a…
Analytical Investigation and Control System Set-up of Medium Scale PV Plants for Power Flow Management
2012
In the field of photovoltaic (PV) plants and energy conversion from renewable sources, a large part of the technical literature is more devoted to practical aspects (new solar cells, electrically driven PV panels, safety, reduction of parasitic currents, etc.) than to theoretical investigations. Despite this tendency, this paper presents a mathematical analysis of a medium scale photovoltaic power generation system connected to the distribution network and of its control system. In such a system, the conversion stage is unique due to the absence of a boost chopper. The conducted analysis leads to the interesting conclusion that the inverter used in the plant presents two degrees of freedom,…
Frequency stability in microgrid: control strategies and analysis of BESS aging effects
2016
In order to ensure a thorough analysis, all components placed in a microgrid would have to be considered to guarantee an effective energy management. To this aim, various algorithms are used both to preserve and restore power systems after significant disturbances. However, these models frequently do not evaluate components performance decline with the age and, consequently, they don't consider actual values during microgrid analysis, potentially affecting obtained results. In particular, evaluating energy storage systems aging and their effects has rarely been addressed in prior works. The present article proposes a model to maintain power system/microgrid stability after disturbances usin…
Currents Distribution During a Fault in an MV Network: Methods and Measurements
2016
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…