Search results for " precession"
showing 10 items of 43 documents
Simulations of continuous-wave sodium laser guide stars with polarization modulation at Larmor frequency
2018
The return flux from a sodium laser guide star suffers, at large angles between the geomagnetic field and the laser beam, from the reduction in optical pumping due to spin-precession of sodium atoms. This detrimental effect can be mitigated by modulating the circular polarization of a continuous-wave laser beam in resonance with the Larmor frequency of sodium atoms in the mesosphere. We present an investigation based on numerical modeling to evaluate the brightness enhancement of a laser guide star with polarization modulation of a continuous-wave laser beam at different observatories.
Towards an Improved Measurement of the Proton Magnetic Moment
2017
The BASE collaboration performed the most precise measurement of the proton magnetic moment. By applying the so-called double Penning-trap method with a single proton a fractional precision of 3.3 parts-per-billion was reached. This article describes the primary limitations of the last measurement and discusses improvements to reach the sub-parts-per-billion level.
Constraints on Spin-Dependent Short-Range Interaction between Nucleons
2013
We report on the search for a new spin-dependent P- and T-violating interaction between nucleons mediated by light, pseudoscalar bosons such as the axion which was invented to solve the strong CP problem. Our experimental approach is to use an ultra-sensitive low-field magnetometer based on the detection of free precession of co-located 3He and 129Xe nuclear spins using SQUIDs as low-noise magnetic flux detectors. In the presence of an unpolarized mass the precession frequency shif
2012
A new apparatus has been designed that aims at a direct precision measurement of the g-factor of a single isolated proton or antiproton in a Penning trap. We present a thorough discussion on the trap design and a method for the experimental trap optimization using a single stored proton. A first attempt at the g-factor determination has been made in a section of the trap with a magnetic bottle. The Larmor frequency of the proton has been measured with a relative uncertainty of 1.8◊10 6 and the magnetic moment has been determined with a relative uncertainty of 8.9◊10 6 . Ag-factor of 5.585696(50) has been obtained, which is in excellent agreement with previous measurements and predictions. F…
Positive Muons as Local Probes in Paramagnetic Rare Earth Systems
1982
In recent years a new research method has been developed in solid state physics which is based on the asymmetry of muon decay1. A positive muon at rest decays after a mean lifetime of 2.2 μsec into a positron and two neutrinos, the positron being emitted preferentially in the direction of the muon spin. Hence if spin polarized muons are implanted in a solid, the time evolution of the muon spin polarization can be determined by a measurement of the angular distribution of the positrons. In an external magnetic field transverse to the initial spin direction of the muon one can study the muon spin precession frequency, which is determined by the actual field at the muon, and τ2-relaxation effe…
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g−2 Experiment
2021
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $\omega_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_{\mu}({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the preces…
A new hydrous Al-bearing pyroxene as a water carrier in subduction zones
2011
Abstract A new Hydrous Al-bearing PYroxene (HAPY) phase has been synthesized at 5.4 GPa, 720 °C in the MgO–Al2O3–SiO2–H2O model system. It has the composition Mg2.1Al0.9(OH)2Al0.9Si1.1O6, a C-centered monoclinic cell with a = 9.8827(2), b = 11.6254(2) c = 5.0828(1) A and β = 111.07(1)°. The calculated density is 3.175 g/cm3 and the water content is 6.9% H2O by weight. Its structure has been solved in space group C2/c by the recently developed automated electron diffraction tomography method and refined by synchrotron X-ray powder diffraction. HAPY is a single chain inosilicate very similar to pyroxenes but with three instead of two cations in the octahedral layer, bonded to four oxygens and…
Semiautomatic detection of myocardial contours in order to investigate normal values of the left ventricular trabeculated mass using MRI
2015
Purpose To propose, assess, and validate a semiautomatic method allowing rapid and reproducible measurement of trabeculated and compacted left ventricular (LV) masses from cardiac magnetic resonance imaging (MRI). Materials and Methods We developed a method to automatically detect noncompacted, endocardial, and epicardial contours. Papillary muscles were segmented using semiautomatic thresholding and were included in the compacted mass. Blood was removed from trabeculae using the same threshold tool. Trabeculated, compacted masses and ratio of noncompacted to compacted (NC:C) masses were computed. Preclinical validation was performed on four transgenic mice with hypertrabeculation of the LV…
Search for Axionlike Dark Matter through Nuclear Spin Precession in Electric and Magnetic Fields
2017
We report on a search for ultralow-mass axionlike dark matter by analyzing the ratio of the spinprecession frequencies of stored ultracold neutrons and 199Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range 10−24 ≤ ma ≤ 10−17 eV. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40. ispartof: Physical Review X vol:7 issue:…
Anthrazyklin-induzierte Kardiotoxizität: MRT des Herzens bei Kindern und Jugendlichen mit malignen Erkrankungen
2004
Purpose: Quantification of left and right ventricular function using MRI in young cancer patients treated with cardiotoxic anthracyclines. Materials and Methods: Twenty-eight patients (mean age 16.4 years) underwent cardiac MRI at 1.5 T. The study protocol consisted of morphologic T2-weighted images with fat suppression and cine steady-state free precession sequences (SSFP) for functional analysis. Seven patients were examined at the end of chemotherapy, two of them also repeatedly during therapy, and 21 patients following an average period of three years after finishing chemotherapy (range one month - 20 years) Results: The end-systolic volume index increased and the ejection fraction of t…