Information content of data and variables and types of weighting in least-squares regression methods

1990

Abstract Algorithms are given for evaluating the relative amount of useful information related to a particular parameter which is carried by individual data points and intervals of the variables. The algorithms provide an efficient means of using the information contained in a set of data. Applications to the optimization of weighting in regression methods are described. Several informational and combined informational-statistical types of weighting are studied as a means of improving the accuracy and precision of the parameters obtained by non-linear regression.

Accuracy and precisionChemistryRegression analysisStatistical weightBiochemistryRegressionAnalytical ChemistryWeightingSet (abstract data type)Content (measure theory)StatisticsEnvironmental ChemistryNonlinear regressionSpectroscopyAnalytica Chimica Acta
researchProduct

Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…

2012

The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…

Accuracy and precisionChemistrybusiness.industryPlasma source mass spectrometryDrop (liquid)NozzleAnalytical chemistryStandard solutionAnalytical ChemistryMatrix (chemical analysis)Aerosol generatorOn demandProcess engineeringbusinessSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction

2001

Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.

Accuracy and precisionChromatographyInjection ProcedureExtraction (chemistry)Fluorescence spectrometryAnalytical chemistryAnalytical Chemistrychemistry.chemical_compoundchemistryLiquid–liquid extractionReagentStandard additionDiethyl etherSpectroscopyMicrochemical Journal
researchProduct

Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…

2000

The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…

Accuracy and precisionGeneral Chemical EngineeringAnalytical chemistrychemistry.chemical_elementGeneral ChemistryIsotope dilutionPolyethyleneMass spectrometryMatrix (chemical analysis)Chromiumchemistry.chemical_compoundThird phasechemistrySafety Risk Reliability and QualityInstrumentationInductively coupled plasma mass spectrometryAccreditation and Quality Assurance
researchProduct

Development of microextraction techniques in combination with GC-MS/MS for the determination of mycotoxins and metabolites in human urine.

2017

Simple and highly efficient sample preparation procedures, namely, dispersive liquid–liquid microextraction and salting-out liquid–liquid extraction for the analysis of ten Fusarium mycotoxins and metabolites in human urine were compared. Various parameters affecting extraction efficiency were carefully evaluated. Under optimal extraction conditions, salting-out liquid–liquid extraction showed a better accuracy (84–96%) and precision (<14%) than dispersive liquid–liquid microextraction. Hence, a multibiomarker method based on salting-out liquid–liquid extraction followed by gas chromatography with tandem mass spectrometry was proposed. Satisfactory results in terms of validation were achiev…

Accuracy and precisionLiquid Phase MicroextractionFiltration and SeparationPilot ProjectsUrineUrinalysisTandem mass spectrometry01 natural sciencesGas Chromatography-Mass SpectrometryAnalytical Chemistry0404 agricultural biotechnologyLimit of DetectionTandem Mass SpectrometryHumansSample preparationDetection limitChromatographyChemistry010401 analytical chemistryExtraction (chemistry)04 agricultural and veterinary sciencesMycotoxins040401 food science0104 chemical sciencesGas chromatographyGas chromatography–mass spectrometryJournal of separation science
researchProduct

A comprehensive characterization of ice nucleation by three different types of cellulose particles immersed in water: lessons learned and future rese…

2018

We present the laboratory results of immersion freezing efficiencies of cellulose particles at supercooled temperature (T) conditions. Three types of chemically homogeneous cellulose samples are used as surrogates that represent supermicron and submicron ice nucleating plant structural polymers. These samples include micro-crystalline cellulose (MCC), fibrous cellulose (FC) and nano-crystalline cellulose (NCC). Our experimental data show that particles resembling the MCC lab particle occur also in the atmosphere. Our immersion freezing dataset includes data from various ice nucleation measurement techniques available at seventeen different institutions, including nine dry dispersion and ele…

Accuracy and precisionMaterials science010504 meteorology & atmospheric sciencesAnalytical chemistry01 natural scienceschemistry.chemical_compoundchemistrySpectral slopeIce nucleusParticleCelluloseSupercoolingDispersion (chemistry)Order of magnitude0105 earth and related environmental sciences
researchProduct

Steam sterilization processes affect the stability of clinical thermometers: Thermistor and prototypal FBG probe comparison

2020

Abstract Temperature is one of the most frequently measured physical quantities in clinical environment and a good biomarker of illness. The need for reusable probes, which have to be sterilized to prevent infections, requires the metrological qualification of thermometer probes in response to ageing effects induced by several sterilization processes. In this study, we investigated the effect of repeated sterilizations on both a commonly-used autoclavable thermistor probe and a prototypal Fiber Bragg Gratings (FBG) probe for temperature measurements. Findings highlighted a greater reliability of the proposed FBG probe than the commercial thermistor. Specifically, the FBG probe was able to w…

Accuracy and precisionMaterials science02 engineering and technology01 natural sciencesTemperature measurement010309 optics020210 optoelectronics & photonicsFiber Bragg gratingThermistor0103 physical sciences0202 electrical engineering electronic engineering information engineeringBiomedical sensorsElectrical and Electronic EngineeringInstrumentationbusiness.industryThermistorSterilizationAtomic and Molecular Physics and OpticsSteam sterilizationElectronic Optical and Magnetic MaterialsFiber Bragg Grating (FBG)Control and Systems EngineeringThermometerBiomedical sensorOptoelectronicsClinical thermometerbusinessOptical Fiber Technology
researchProduct

Determination of phosphorus by instrumental neutron activation and bremsstrahlung measurement in bone samples

1997

A non destructive method based on the31P(n,γ)32P reaction for the assay of phosphorus in bone samples is described. This method involves a thermal neutron irradiation of 2 minutes in a reactor followed by the measurement of the bremsstrahlung produced by the β− of32P in a Ge-detector surrounded by an anti-Compton shield. Accuracy and precision were tested by analysing the certified NIST 1486 Bone Meal reference material and tri-calcium phosphate (Ca3(PO4)2) samples. The value obtained for the reference material was in good agreement with the certified value and with relative standard deviation of 4.1% the precision was acceptable. The value obtained for Ca3(PO4)2 shows a deviation of −6% fr…

Accuracy and precisionMaterials scienceHealth Toxicology and MutagenesisPhosphorusRadiochemistryPublic Health Environmental and Occupational HealthAnalytical chemistryBremsstrahlungchemistry.chemical_elementPollutionNeutron temperatureBone mealAnalytical ChemistryNuclear Energy and EngineeringchemistryNon destructiveRadiology Nuclear Medicine and imagingIrradiationSpectroscopyNeutron activationJournal of Radioanalytical and Nuclear Chemistry
researchProduct

Effectiveness of microwave based digestion procedures for the demineralization of human milk and infant formulas prior to fluorometric determination …

1996

The use of two types of microwave oven, one domestic (A) and the other specially designed for laboratory (B) for microwave-based digestion, to destroy the organic matter in milk and infant formulas prior to fluorometric determination of selenium is studied in order to check their applicability and reliability. In both systems the best results were obtained using the acid mixture HNO3—H2O2, and additional treatment with perchloric acid (60%) in a Thermoblock. The application of two different microwave-based digestion procedures to infant formulas was free of interferences. In the case of human milk, it was necessary to use the standard addition method. Values obtained for detection and quant…

Accuracy and precisionMineralsChromatographyMilk HumanMicrowave ovenAnalytical chemistryFluorescence spectrometryInfant Newbornchemistry.chemical_elementInfantDemineralizationSeleniumDigestion (alchemy)Spectrometry FluorescencechemistryInfant formulaStandard additionHumansFemaleIndicators and ReagentsInfant FoodMicrowavesSeleniumFood Science
researchProduct

Multivariate standardisation for non-linear calibration range in the chemiluminescence determination of chromium.

2006

Multivariate standardisation is proposed for the successful chemiluminescence determination of chromium based on luminol-hydrogen peroxide reaction. In an extended concentration range, non-linear calibration model is needed. The studied instrumental situations were different detection cells, instruments, assemblies, time and their possible combinations. Chemiluminescence kinetic registers have been transferred using piecewise direct standardisation (PDS) method. The optimisation of transfer parameters has been carried out based on the prediction residual error criteria. Non-linear principal component regression (NL-PCR) and non-linear partial least square regression (NL-PLS) were chosen for…

Accuracy and precisionMultivariate statisticsChemistrylawDirect methodPartial least squares regressionLinear regressionCalibrationAnalytical chemistryPrincipal component regressionAnalytical ChemistryChemiluminescencelaw.inventionTalanta