Information content of data and variables and types of weighting in least-squares regression methods
1990
Abstract Algorithms are given for evaluating the relative amount of useful information related to a particular parameter which is carried by individual data points and intervals of the variables. The algorithms provide an efficient means of using the information contained in a set of data. Applications to the optimization of weighting in regression methods are described. Several informational and combined informational-statistical types of weighting are studied as a means of improving the accuracy and precision of the parameters obtained by non-linear regression.
Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…
2012
The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…
Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction
2001
Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.
Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…
2000
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…
Development of microextraction techniques in combination with GC-MS/MS for the determination of mycotoxins and metabolites in human urine.
2017
Simple and highly efficient sample preparation procedures, namely, dispersive liquid–liquid microextraction and salting-out liquid–liquid extraction for the analysis of ten Fusarium mycotoxins and metabolites in human urine were compared. Various parameters affecting extraction efficiency were carefully evaluated. Under optimal extraction conditions, salting-out liquid–liquid extraction showed a better accuracy (84–96%) and precision (<14%) than dispersive liquid–liquid microextraction. Hence, a multibiomarker method based on salting-out liquid–liquid extraction followed by gas chromatography with tandem mass spectrometry was proposed. Satisfactory results in terms of validation were achiev…
A comprehensive characterization of ice nucleation by three different types of cellulose particles immersed in water: lessons learned and future rese…
2018
We present the laboratory results of immersion freezing efficiencies of cellulose particles at supercooled temperature (T) conditions. Three types of chemically homogeneous cellulose samples are used as surrogates that represent supermicron and submicron ice nucleating plant structural polymers. These samples include micro-crystalline cellulose (MCC), fibrous cellulose (FC) and nano-crystalline cellulose (NCC). Our experimental data show that particles resembling the MCC lab particle occur also in the atmosphere. Our immersion freezing dataset includes data from various ice nucleation measurement techniques available at seventeen different institutions, including nine dry dispersion and ele…
Steam sterilization processes affect the stability of clinical thermometers: Thermistor and prototypal FBG probe comparison
2020
Abstract Temperature is one of the most frequently measured physical quantities in clinical environment and a good biomarker of illness. The need for reusable probes, which have to be sterilized to prevent infections, requires the metrological qualification of thermometer probes in response to ageing effects induced by several sterilization processes. In this study, we investigated the effect of repeated sterilizations on both a commonly-used autoclavable thermistor probe and a prototypal Fiber Bragg Gratings (FBG) probe for temperature measurements. Findings highlighted a greater reliability of the proposed FBG probe than the commercial thermistor. Specifically, the FBG probe was able to w…
Determination of phosphorus by instrumental neutron activation and bremsstrahlung measurement in bone samples
1997
A non destructive method based on the31P(n,γ)32P reaction for the assay of phosphorus in bone samples is described. This method involves a thermal neutron irradiation of 2 minutes in a reactor followed by the measurement of the bremsstrahlung produced by the β− of32P in a Ge-detector surrounded by an anti-Compton shield. Accuracy and precision were tested by analysing the certified NIST 1486 Bone Meal reference material and tri-calcium phosphate (Ca3(PO4)2) samples. The value obtained for the reference material was in good agreement with the certified value and with relative standard deviation of 4.1% the precision was acceptable. The value obtained for Ca3(PO4)2 shows a deviation of −6% fr…
Effectiveness of microwave based digestion procedures for the demineralization of human milk and infant formulas prior to fluorometric determination …
1996
The use of two types of microwave oven, one domestic (A) and the other specially designed for laboratory (B) for microwave-based digestion, to destroy the organic matter in milk and infant formulas prior to fluorometric determination of selenium is studied in order to check their applicability and reliability. In both systems the best results were obtained using the acid mixture HNO3—H2O2, and additional treatment with perchloric acid (60%) in a Thermoblock. The application of two different microwave-based digestion procedures to infant formulas was free of interferences. In the case of human milk, it was necessary to use the standard addition method. Values obtained for detection and quant…
Multivariate standardisation for non-linear calibration range in the chemiluminescence determination of chromium.
2006
Multivariate standardisation is proposed for the successful chemiluminescence determination of chromium based on luminol-hydrogen peroxide reaction. In an extended concentration range, non-linear calibration model is needed. The studied instrumental situations were different detection cells, instruments, assemblies, time and their possible combinations. Chemiluminescence kinetic registers have been transferred using piecewise direct standardisation (PDS) method. The optimisation of transfer parameters has been carried out based on the prediction residual error criteria. Non-linear principal component regression (NL-PCR) and non-linear partial least square regression (NL-PLS) were chosen for…