Search results for " press"
showing 10 items of 4213 documents
Study of separation of water + 2-propanol mixture using different ionic liquids: 1-Butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-b…
2018
Abstract The liquid–liquid equilibria data of water (1) + 2-propanol (2) + [bmim][Tf2N] (3) and water (1) + 2-propanol (2) + [bmp][Tf2N] (3) at 283.2, 303.2 and 323.2 K and atmospheric pressure were measured with the objective of understanding the behavior of these two systems and to try to improve the extraction of 2-propanol from water from economical and environmental points of view. The thermodynamic parameters were determined using the non-random two-liquid (NRTL) and universal quasichemical (UNIQUAC) models, and excellent results were achieved in both cases (the maximum root-mean-square deviation was 0.433%). Lastly, the capability of the two ionic liquids to separate 2-propanol from …
Related haloarchaeal pleomorphic viruses contain different genome types
2012
Archaeal viruses have been the subject of recent interest due to the diversity discovered in their virion architectures. Recently, a new group of haloarchaeal pleomorphic viruses has been discovered. It is distinctive in terms of the virion morphology and different genome types (ssDNA/dsDNA) harboured by rather closely related representatives. To date there are seven isolated viruses belonging to this group. Most of these share a cluster of five conserved genes, two of which encode major structural proteins. Putative proviruses and proviral remnants containing homologues of the conserved gene cluster were also identified suggesting a long-standing relationship of these viruses with their ho…
Studies of the bromine spectrum and determination of transition probabilities for Br I and Br II lines
1999
In a wall-stabilized cascade arc at atmospheric pressure in mixtures of argon and bromine vapors thermal plasmas were generated. Arc currents between 25 and 60 A were used. Applying a spectrometer of medium dispersion, equipped with an optical multichannel analyzer (CCD detector), the spectra of neutral and singly ionized bromine in the range between 3300 and 10400 A were recorded. Line intensity measurements, corrected for self-absorption, at different operating conditions of the arc, were performed. A complete set of Br I transitions (5 lines) originating from a common upper level (branching fractions) was measured. In the case of the Br II spectrum intensities of 14 lines were determined…
Study of Inductive Coupled Hydrogen and Argon Plasma Interaction with SiO2 Glass
2009
This work is devoted to the diagnostics of interaction between hydrogen and argon with the surface of SiO2 glass walls. For diagnostics of the interaction, special high-frequency electrodeless light sources were prepared, filled with pure argon of 1 Torr or argon-hydrogen of total pressure of 1 Torr (Ar/H2 mixing ratio is 9:1). Besides the mostly used spherical and cylindrical lamps, dumbbell type lamps have also been investigated. The spectroscopic and AFM measurements showed that in comparison with pure argon plasma, the argon-hydrogen plasma causes non-uniform changes of the SiO2 surface. For these modifications active OH are primarily responsible molecules, created in the reactions of h…
Influence of the metabolic syndrome on aortic stiffness in never treated hypertensive patients
2004
Summary Background and aim Metabolic syndrome (MS) carries an increased risk for cardiovascular events and there is a growing awareness that large artery stiffening is a powerful predictor of cardiovascular morbidity and mortality. Little is known about the relationship of MS with aortic stiffness. The aim of our study was to analyze, in patients with essential hypertension, the influence of MS, defined according to the criteria proposed by the Third Report of the National Cholesterol Education Program Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (NCEP-ATP III), on carotid–femoral pulse wave velocity (PWV), a measure of aortic stiffness. Methods N…
[PP.07.19] ASSOCIATION OF MAXIMUM SPEED OF BLOOD PRESSURE RISE DURING 24-H ABPM WITH SUBCLINICAL RENAL DAMAGE IN ESSENTIAL HYPERTENSION
2017
Objective: Experimental studies documented that the mechanical injury of intravascular pressure on the vessel wall, which results in vascular remodelling and atherosclerosis, may be more closely associated to oscillatory than to steady laminar shear stress This suggests that the hypertensive patient's prognosis may depend not only on average BP level but also on the degree and rate of BP variation. Little is known about the relationships between early renal abnormalities and the rate of BP changes assessed by intermittent 24-h ambulatory BP monitoring (ABPM). Our study was aimed to analyse the relationships between subclinical renal damage (SRD), defined as the presence of microalbuminuria …
Arterial hypertension in cancer: The elephant in the room
2019
The great therapeutical success achieved by oncology is counterbalanced by growing evidences of cardiovascular (CV) toxicity due to many antineoplastic treatments. Cardiac adverse events may cause premature discontinuation of effective oncologic treatments or occur as late events undermining the oncologic success. Arterial hypertension is both the most common comorbidity in cancer patients and a frequent adverse effect of anticancer therapies. A pre-existing hypertension is known to increase the risk of other cardiac adverse events due to oncologic treatments, in particular heart failure. Moreover, as a strict association between cancer and CV diseases has emerged over the recent years, var…
European society of hypertension position paper on ambulatory blood pressure monitoring
2013
Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of dev…
The Relationship Between Aortic Root Size and Hypertension: An Unsolved Conundrum
2017
Thoracic aortic aneurysms rupture and dissection are among the most devastating vascular diseases, being characterized by elevated mortality, despite improvements in diagnostic imaging and surgical techniques. An increased aortic root diameter (ARD) represents the main risk factor for thoracic aortic dissection and rupture and for aortic valve regurgitation. Even though arterial hypertension is commonly regarded as a predisposing condition for the development of thoracic aorta aneurysms, the role of blood pressure (BP) as determinant of aortic root enlargement is still controversial. The use of different methods for indexation of ARD may have in part contributed to the heterogeneous finding…
Neurogenic pulmonary oedema after generalized epileptic seizure
1998
The diagnosis 'tonic clonic seizure' is frequently established by emergency physicians on scene. In patients with epilepsy mortality due to accidents, asphyxia, cardiac arrhythmias or postictal neurogenic pulmonary oedema (NPO) is twice as high as in the general population. We report a case of acute pulmonary oedema after a tonic clonic seizure. Following this event, the patient developed respiratory insufficiency and evidence of pulmonary oedema not associated with the classic aetiologies of congestive heart failure, aspiration or toxic exposure. The patient survived the incident after aggressive prehospital treatment, long-term intensive care and subsequent rehabilitation. A systematic ca…