Search results for " processing"

showing 10 items of 7549 documents

Multiple levels of MHC class I down-regulation by ras oncogenes.

1996

A number of tumours and oncogene transformed cells displayed reduced MHC class I surface expression which seemed to enable their escape from immune surveillance. To test whether oncogenic activation is directly involved in suppressing MHC class I expression, a model of inducible oncogene expression was chosen. Mouse fibroblasts transfected with different oncogenes expressed under the control of the dexamethasone-inducible MMTV promoter were analysed in the presence and absence of hormone for the mRNA and protein expression of MHC class I molecules as well as the respective oncogenes. Immunofluorescence analyses demonstrated an inverse association of MHC class I and oncogene expression after…

CD74Transcription GeneticImmunologyCD1Down-RegulationGene ExpressionC-C chemokine receptor type 7TransfectionDexamethasoneMiceAntigenMHC class IAnimalsRNA Processing Post-TranscriptionalPromoter Regions GeneticMessenger RNAbiologyOncogeneHistocompatibility Antigens Class IGeneral Medicine3T3 CellsMHC restrictionMolecular biologyGenes rasMammary Tumor Virus MouseAntigens Surfacebiology.proteinImmunoglobulin Heavy Chainsbeta 2-MicroglobulinScandinavian journal of immunology
researchProduct

3D Integration : towards high-performance innovative imaging sensors

2017

Nowadays, CMOS image sensors are almost exclusively architectured around analog pixels. A transition to purely digital pixels would significantly improve the performances of imagers. Unfortunately, such an approach is difficult to consider because it causes an oversized and unusable pixel for the consumer market. One of the promising ways to solve this problem of pixel integration is to think not only in 2D dimensions, but in 3D dimensions by distributing the different functionalities on several interconnected wafers.Thus, the work presented in this manuscript describes the design of a purely digital image sensor in CMOS 3D-IC 130 nm Tezzaron technology. This sensor is architectured around …

CMOS 130nm FaStack TEZZARONIntégration 3DPixel intelligentModulation Sigma DeltaDigital Pixel SensorSmart pixel3d icDelta Sigma ModultaionCapteur d'image à pixel numérique[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Attitude measurement by artificial vision

2005

The recent development of light and low-cost airborne platforms (microlight, drones, kites, balloons,...) has led to the need for simple and low-cost devices allowing attitude measurement with respect to a reference horizon of the platform itself or of an embedded setting. A theoretical study of the conditions for measuring attitude angles from artificial vision is proposed and an original practical algorithm allowing these measurements to be performed in real time is described. An implementation in a CMOS retina circuit is also presented. These points are illustrated by experiments confirming the feasibility of the device.

CMOSSIMPLE (military communications protocol)Computer scienceArtificial visionApplied MathematicsPractical algorithmImage processingInstrumentationEngineering (miscellaneous)SimulationDroneRemote sensingMeasurement Science and Technology
researchProduct

Measurement of the muon neutrino inclusive charged-current cross section in the energy range of 1–3 GeV with the T2K INGRID detector

2016

International audience; We report a measurement of the $\nu_{\mu}$-nucleus inclusive charged current cross section (=$\sigma^{cc}$) on iron using data from exposed to the J-PARC neutrino beam. The detector consists of 14 modules in total, which are spread over a range of off-axis angles from 0$^\circ$ to 1.1$^\circ$. The variation in the neutrino energy spectrum as a function of the off-axis angle, combined with event topology information, is used to calculate this cross section as a function of neutrino energy. The cross section is measured to be $\sigma^{cc}(1.1\text{ GeV}) = 1.10 \pm 0.15$ $(10^{-38}\text{cm}^2/\text{nucleon})$, $\sigma^{cc}(2.0\text{ GeV}) = 2.07 \pm 0.27$ $(10^{-38}\te…

COLLISIONSNuclear and High Energy PhysicsParticle physicsMULTIPLICITY DISTRIBUTIONSPhysics::Instrumentation and Detectors530 PhysicsFOS: Physical sciencesneutrino scatteringAstronomy & Astrophysics01 natural sciences7. Clean energyHigh Energy Physics - ExperimentPhysics Particles & FieldsNuclear physicsHigh Energy Physics - Experiment (hep-ex)Cross section (physics)0202 Atomic Molecular Nuclear Particle And Plasma PhysicsMONTE-CARLO0103 physical sciencesPION ABSORPTION[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Muon neutrino010306 general physicsNuclear Experiment0206 Quantum PhysicsCharged currentPhysicsRange (particle radiation)Science & TechnologyNUCLEIhep-ex010308 nuclear & particles physicsPhysicsneutrinoscross sectionsNuclear & Particles Physics0201 Astronomical And Space SciencesPhysical SciencesSIMULATIONHigh Energy Physics::ExperimentNeutrinoNucleonEvent (particle physics)Energy (signal processing)
researchProduct

3D segmentation of abdominal aorta from CT-scan and MR images

2012

International audience; We designed a generic method for segmenting the aneurismal sac of an abdominal aortic aneurysm (AAA) both from multi-slice MR and CT-scan examinations. It is a semi-automatic method requiring little human intervention and based on graph cut theory to segment the lumen interface and the aortic wall of AAAs. Our segmentation method works independently on MRI and CT-scan volumes and has been tested on a 44 patient dataset and 10 synthetic images. Segmentation and maximum diameter estimation were compared to manual tracing from 4 experts. An inter-observer study was performed in order to measure the variability range of a human observer. Based on three metrics (the maxim…

CT scanmedicine.medical_specialty[INFO.INFO-IM] Computer Science [cs]/Medical ImagingLumen (anatomy)Health Informatics02 engineering and technologyAAA segmentationPattern Recognition Automated030218 nuclear medicine & medical imaging03 medical and health sciencesAortic aneurysmImaging Three-Dimensional0302 clinical medicineCutmedicine.arteryImage Interpretation Computer-Assisted[INFO.INFO-IM]Computer Science [cs]/Medical Imaging0202 electrical engineering electronic engineering information engineeringmedicineHumansRadiology Nuclear Medicine and imagingSegmentationMathematicsAnalysis of VarianceRadiological and Ultrasound Technology[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingVolume segmentationAbdominal aortaReproducibility of Resultsmedicine.diseaseComputer Graphics and Computer-Aided DesignAbdominal aortic aneurysmHausdorff distancecardiovascular system020201 artificial intelligence & image processingComputer Vision and Pattern RecognitionTomographyRadiologyTomography X-Ray ComputedAlgorithmsMagnetic Resonance AngiographyGraph cutAortic Aneurysm AbdominalMRI
researchProduct

A Fast GPU-Based Motion Estimation Algorithm for H.264/AVC

2012

H.264/AVC is the most recent predictive video compression standard to outperform other existing video coding standards by means of higher computational complexity. In recent years, heterogeneous computing has emerged as a cost-efficient solution for high-performance computing. In the literature, several algorithms have been proposed to accelerate video compression, but so far there have not been many solutions that deal with video codecs using heterogeneous systems. This paper proposes an algorithm to perform H.264/AVC inter prediction. The proposed algorithm performs the motion estimation, both with full-pixel and sub-pixel accuracy, using CUDA to assist the CPU, obtaining remarkable time …

CUDAComputational complexity theoryComputer scienceMotion estimationComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONCodecSymmetric multiprocessor systemImage processingData_CODINGANDINFORMATIONTHEORYCentral processing unitParallel computingData compression
researchProduct

Cadmium mass measurements between the neutron shell closures at N=50 and 82

2010

International audience; The mass values of the neutron-deficient cadmium isotopes 99−109Cd and of the neutronrich isotopes 114,120,122−124,126,128Cd have been measured using ISOLTRAP. The behavior of the separation energies of the cadmium isotopes from N = 50 to 82 is discussed.

CadmiumIsotopehigh-precision mass measurementsChemistryStable isotope ratioPenning trapRadiochemistrychemistry.chemical_element020206 networking & telecommunications02 engineering and technology[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]ISOLTRAP7. Clean energyISOLTRAPcadmium massesIsotope separationlaw.inventionlawIsotopes of cadmium0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingNeutron21.10.Dr 21.30.Fe 27.60.+j 32.10.BiNucleon
researchProduct

Glutamatergic projection from the nucleus incertus to the septohippocampal system

2012

Abstract Recent findings support a relevant role of the nucleus incertus in the control of the hippocampal activity through the modulation of theta rhythm. Previous studies from our group have shown that this nucleus is a critical relay between reticularis pontis oralis and the medial septum/diagonal band, regarded as the main activator and the pacemaker of the hippocampal oscillations, respectively. Besides, the nucleus incertus is highly linked to activated states related to the arousal response. The neurotransmission of the nucleus incertus, however, remains uncertain. Only GABA and the neuromodulator relaxin 3 are usually considered to be involved in its contribution to the septohippoca…

CalbindinsTissue FixationHippocampal formationBiologyDiagonal Band of BrocaHippocampusCalbindinRats Sprague-DawleyGlutamatergicS100 Calcium Binding Protein GGlutamatesPonsImage Processing Computer-AssistedmedicineAnimalsBrain MappingPars compactaReticular FormationGeneral NeuroscienceElectroencephalographyImmunohistochemistryNucleus IncertusRatsmedicine.anatomical_structureMicroscopy Fluorescencenervous systemCalbindin 2Data Interpretation StatisticalVesicular Glutamate Transport Protein 2FemaleSeptum of BrainCalretininRelaxin-3NeuroscienceNucleusNeuroscience Letters
researchProduct

Exponential instability in the fractional Calder\'on problem

2017

In this note we prove the exponential instability of the fractional Calder\'on problem and thus prove the optimality of the logarithmic stability estimate from \cite{RS17}. In order to infer this result, we follow the strategy introduced by Mandache in \cite{M01} for the standard Calder\'on problem. Here we exploit a close relation between the fractional Calder\'on problem and the classical Poisson operator. Moreover, using the construction of a suitable orthonormal basis, we also prove (almost) optimality of the Runge approximation result for the fractional Laplacian, which was derived in \cite{RS17}. Finally, in one dimension, we show a close relation between the fractional Calder\'on pro…

Calderón problemApplied Mathematics010102 general mathematicsMathematics::Classical Analysis and ODEs01 natural sciencesInstabilityinversio-ongelmatComputer Science ApplicationsTheoretical Computer ScienceExponential functionHilbert transform010101 applied mathematicsMathematics - Analysis of PDEsSignal ProcessingApplied mathematics0101 mathematicsPoisson operatorMathematical PhysicsMathematics
researchProduct

FPGA implementation of a deep learning algorithm for real-time signal reconstruction in particle detectors under high pile-up conditions

2019

The analog signals generated in the read-out electronics of particle detectors are shaped prior to the digitization in order to improve the signal to noise ratio (SNR). The real amplitude of the analog signal is then obtained using digital filters, which provides information about the energy deposited in the detector. The classical digital filters have a good performance in ideal situations with Gaussian electronic noise and no pulse shape distortion. However, high-energy particle colliders, such as the Large Hadron Collider (LHC) at CERN, can produce multiple simultaneous events, which produce signal pileup. The performance of classical digital filters deteriorates in these conditions sinc…

Calibration and fitting methods010308 nuclear & particles physicsSignal reconstructionComputer scienceCluster findingDetectorTime signal01 natural sciencesSignal030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSignal-to-noise ratioAnalog signalPattern recognitionData processing methods0103 physical sciencesSimulation methods and programsInstrumentationDigital filterAlgorithmMathematical PhysicsEnergy (signal processing)Journal of Instrumentation
researchProduct