Search results for " prosthesis"
showing 10 items of 441 documents
Numerical simulations on periprosthetic bone remodeling: a systematic review
2021
Abstract Background and objective The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. Methods A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeli…
A biphasic calcium phosphate coating for potential drug delivery affects early osseointegration of titanium implants.
2016
Background Calcium phosphate (CaP) surface coatings may accelerate osseointegration and serve as a drug delivery system for mineral-binding biomolecules. In a pilot study, the impact of a commercially available, thin CaP coating on early osseous bone remodeling was compared with a modern, subtractive-treated rough surface (SLA-like) in an animal trial. Methods In 16 rabbits, 32 endosseous implants (CaP; n = 16, SLA-like; n = 16) were bilaterally inserted in the proximal tibia after randomization. After 2 and 4 weeks, bone-implant contact (BIC;%) in the cortical (cBIC) and the trabecular bone (sBIC) as well as volume of bone within the screw thread with the highest amount of new-formed bone …
Computed tomography imaging needs for novel transcatheter tricuspid valve repair and replacement therapies
2020
Abstract Transcatheter tricuspid valve therapies are an emerging field in structural heart interventions due to the rising number of patients with severe tricuspid regurgitation and the high risk for surgical treatment. Computed tomography (CT) allows exact measurements of the annular plane, evaluation of adjacent structures, assessment of the access route, and can also be used to identify optimal fluoroscopic projection planes to enhance periprocedural imaging. This review provides an overview of current transcatheter tricuspid valve repair and replacement therapies and to what extent CT can support these interventions.
Centre procedural volume and adverse in‐hospital outcomes in patients undergoing percutaneous transvenous edge‐to‐edge mitral valve repair usingMitra…
2021
AIMS The number of transcatheter mitral valve repair (TMVr) procedures has increased substantially during the last years. A better understanding of the relationship between hospital volume of transcatheter transvenous mitral valve repairs using MitraClip® and patient outcomes may provide information for future policy decisions to improve patient management. METHODS AND RESULTS We analysed patient characteristics and in-hospital outcomes for all TMVr procedures using MitraClip® performed in Germany from 2011 to 2017. Hospitals were stratified according to centre volumes and patients were compared for baseline characteristics and adverse in-hospital events. Overall, 24 709 inpatients were tre…
Tricuspid valve repair with the Cardioband system: two-year outcomes of the multicentre, prospective TRI-REPAIR study
2021
AIMS: Tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. We report one- and two-year outcomes of the Cardioband tricuspid valve reconstruction system in the treatment of ≥moderate functional TR in the TRI-REPAIR study. METHODS AND RESULTS: Thirty patients were enrolled in this single-arm, multicentre, prospective study. Patients were evaluated as having ≥moderate, symptomatic functional TR and deemed inoperable due to unacceptable surgical risk. Clinical, functional, and echocardiographic data were prospectively collected up to two years (mean duration 604±227 days). At baseline, 83% were in NYHA Class III-IV, and the mean LVEF…
External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.
2007
Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…
Biological responses to individualized small titanium implants for the treatment of focal full-thickness knee cartilage defects in a sheep model.
2019
Abstract Background The present study aimed to evaluate the functional, radiological and histological outcome of a customized focal implant for the treatment of focal full-thickness cartilage defects in sheep. Methods The study used magnetic resonance imaging data as the basis for construction of the titanium implant using a three-dimensional printing technique. This was then placed on the medial condyle of the knee joint in eight sheep and left in place in vivo over a period of six months. Following euthanasia, the local biological response was analyzed using micro-computed tomography, light microscopy and histological evaluation (International Cartilage Repair Society (ICRS) score). The v…
Wearing complete dental prostheses - Effects on perioral morphology.
2015
Background: To adequately perform rehabilitation of edentulous patients by a complete removable dental prosthesis (CRDP) is from basic interest to dentists to understand the morphologic changes caused by re-establishment of a physiologic jaw relationship. Anthropometric analyses of standardized frontal view and profile photographs may help elucidate such changes. Material and Methods: Photographs of 31 edentulous patients were compared in relaxed lip closure and after insertion of a CRDP in stable occlusion. 2232 anthropometric distances were raised. Eighteen anthropometric indices reflecting the perioral morphology and its integration in the vertical facial harmony were investigated. Resul…
A prospective, multi-center, practice-based cohort study on all-ceramic crowns
2021
The aim of this prospective, multi-center, practice-based cohort study was to analyze factors associated with the success of all-ceramic crowns.All-ceramic crowns placed in a practice-based research network ([Ceramic Success Analysis, AG Keramik) were analyzed. Data from 1254 patients with (mostly in-office CAD/CAM) all-ceramic crowns placed by 101 dentists being followed up for more than 5 years were evaluated. At the last follow-up visit crowns were considered as successful (not failed) if they were sufficient, whereas crowns were considered as survived (not lost) if they were still in function. Multi-level Cox proportional hazards models were used to evaluate the association between a ra…
Bioactive Glass-Ceramics in Middle Ear Surgery An 8-Year Review
1988
An 8-year follow-up of Ceravital middle ear prostheses showed there was extremely good tolerance in the middle ear space. Incompatibility phenomena were not observed, and inflammatory reactions were neither caused nor supported by the implants. The tympanoplasties were always performed without interposition of cartilage between the tympanic membrane or the tympanic membrane graft and the disk-shaped portion of the implant, and extrusions were never observed. Long-lasting inflammatory processes appeared to destroy implants the same way they destroy ossicles. Transient inflammatory periods (such as episodes of purulent otitis media, which occurred soon after the prostheses were implanted) did…