Search results for " prosthesis"

showing 10 items of 441 documents

Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

2012

Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …

Malemedicine.medical_specialtyTime FactorsEndoleakmedicine.medical_treatmentEVAR aneurysm chimney periscopesAortic Diseases610 Medicine & healthKaplan-Meier EstimateRevascularizationBalloonProsthesis DesignSettore MED/22 - Chirurgia VascolareAortographyRisk Assessment2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPredictive Value of TestsRisk FactorsAngioplastyGermanymedicineHumansVascular PatencyComputed tomography angiographyAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryStentPerioperativemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgerySurgeryBlood Vessel ProsthesisStenosisTreatment OutcomeCuffSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonSwitzerlandJournal of vascular surgery
researchProduct

The DETOUR procedure: no more need for conventional bypass surgery?

2018

Background Long segment occlusive disease in the superficial femoral artery remains a treatment challenge despite advances in open surgical and endovascular approaches. We report initial clinical results of an entirely new procedure to perform percutaneous femoro-popliteal bypass using the DETOUR System. First-in-human patients were performed in New Zealand from December 2013 to June 2014. After modifications to the technique and devices had significantly refined the procedure, the Detour I Trial commenced. Methods Review of initial results in the first five patients treated at a single site enrolled in IRB-approved, prospective clinical study using the DETOUR System. All patients signed in…

Malemedicine.medical_specialtyTime FactorsPercutaneousComputed Tomography AngiographyDeep veinmedicine.medical_treatmentFemoral veinConstriction PathologicFemoral artery030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingBlood Vessel Prosthesis ImplantationPeripheral Arterial Disease03 medical and health sciences0302 clinical medicineRecurrenceBlood vessel prosthesismedicine.arterymedicineHumansProspective StudiesVascular PatencyAgedAged 80 and overbusiness.industryEndovascular ProceduresStentPhlebographyGeneral MedicineMiddle AgedLatviaPopliteal arteryBlood Vessel ProsthesisSurgeryFemoral ArteryTreatment Outcomemedicine.anatomical_structureBypass surgeryFemaleStentsSurgeryCardiology and Cardiovascular MedicinebusinessThe Journal of Cardiovascular Surgery
researchProduct

Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.

2021

Background Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. Methods This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. Results A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were sim…

Malemedicine.medical_specialtyTime FactorsRenal infarctionmedicine.medical_treatmentUrologyRenal function030204 cardiovascular system & hematologyKidneyEndovascular aneurysm repair030218 nuclear medicine & medical imagingAccessory renal artery03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineRenal ArterymedicineHumansStage (cooking)Renal Insufficiency ChronicSuprarenal fixationAgedRetrospective StudiesAged 80 and overAortic aneurysm repairbusiness.industryEndovascular Proceduresfood and beveragesGeneral Medicinebiochemical phenomena metabolism and nutritionmedicine.diseaseAortic AneurysmBlood Vessel Prosthesiscarbohydrates (lipids)Treatment OutcomeDisease ProgressionSurgeryFemaleCardiology and Cardiovascular MedicinebusinessKidney diseaseGlomerular Filtration RateAnnals of vascular surgery
researchProduct

Early outcomes with a single-sided access endovascular stent

2018

Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …

Malemedicine.medical_specialtyTime FactorsTime Factormedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignAortographySettore MED/22 - Chirurgia Vascolare03 medical and health sciencesAortic aneurysmBlood Vessel Prosthesis ImplantationPostoperative Complications0302 clinical medicineAneurysmBlood vessel prosthesismedicineStentHumansAged; Aortic Aneurysm Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Humans; Male; Middle Aged; Postoperative Complications; Prospective Studies; Prosthesis Design; Time Factors; Tomography X-Ray Computed; Treatment Outcome; Blood Vessel Prosthesis; StentsProspective Studies030212 general & internal medicineStrokeAgedEndovascular Procedurebusiness.industryEndovascular ProceduresStentPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryEuropeProspective StudieBlood Vessel ProsthesiTreatment OutcomeStentsFemaleSurgeryPostoperative ComplicationParaplegiabusinessTomography X-Ray ComputedCardiology and Cardiovascular MedicineAbdominal surgeryAortic Aneurysm AbdominalHuman
researchProduct

Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.

2018

Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignEndovascular aneurysm repairRisk Assessment03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsRisk FactorsmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineMyocardial infarctionAdverse effectStrokeAgedAged 80 and overbusiness.industryPatient SelectionEndovascular ProceduresMiddle Agedmedicine.diseaseThrombosisAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisProsthesis FailureTreatment OutcomeRespiratory failureSurgeryFemaleStentsCardiology and Cardiovascular MedicineParaplegiabusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.

2021

Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAorta ThoracicSeverity of Illness IndexTranscatheter Aortic Valve ReplacementMediastinal fibrosisAortic valve replacementValve replacementFibrosisInternal medicinemedicine.arteryPositron Emission Tomography Computed Tomographyparasitic diseasesAscending aortaMedicineHumansAortitisAgedAortitisbusiness.industryAortic Valve Stenosismedicine.diseaseStenosisAortic valve stenosisAortic ValveHeart Valve ProsthesisImmunoglobulin GCardiologyImmunoglobulin G4-Related Diseasemedicine.symptomCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesThe Canadian journal of cardiology
researchProduct

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.

2016

Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureKaplan-Meier Estimate030204 cardiovascular system & hematologyAnastomosisRevascularizationProsthesis DesignEndovascular aneurysm repairThoracic aortic aneurysmSettore MED/22 - Chirurgia VascolareDisease-Free Survival03 medical and health sciencesAortic aneurysmBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmPostoperative ComplicationsBlood vessel prosthesisRisk Factorsmedicine.arterymedicineHumans030212 general & internal medicineRenal arteryVascular PatencyAgedRetrospective StudiesAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresCardiology and Cardiovascular Medicine; SurgeryMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisTreatment Outcomecardiovascular systemFeasibility StudiesSurgeryFemaleRadiologybusinessCardiology and Cardiovascular MedicineAortic Aneurysm AbdominalJournal of vascular surgery
researchProduct

Trans-popliteal hybrid retrograde technique for revascularization of chronic total occlusions of the superficial femoral artery.

2020

Objectives We present the technical description and preliminary results of a hybrid approach for the treatment of chronic total occlusions of superficial femoral artery in the setting of critical limb-threatening ischemia (CLTI). Methods A retrospective analysis of selected case series was performed. A trans-popliteal hybrid technique was carried out in seven limbs (six patients). Open exposure of above-the-knee popliteal artery was performed over its maximum calcification zone. After retrograde recanalization and graft-stenting of the entire superficial femoral artery, endarterectomy of the popliteal artery was performed for debulking and widening of the distal landing zone of the endopros…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentCritical IllnessConstriction PathologicEndarterectomy030204 cardiovascular system & hematologyRevascularization030218 nuclear medicine & medical imaging03 medical and health sciencesBlood Vessel Prosthesis ImplantationPeripheral Arterial Disease0302 clinical medicineIschemiamedicineHumansRadiology Nuclear Medicine and imagingPopliteal ArteryVascular PatencyAgedRetrospective Studiesbusiness.industrySuperficial femoral arteryEndovascular ProceduresGeneral MedicineCritical limb ischemiaMiddle Agedmedicine.diseaseHybrid approachBlood Vessel ProsthesisFemoral ArteryTreatment OutcomeChronic DiseaseRetrograde approachSurgeryFemaleStentsRadiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessCalcificationVascular
researchProduct

Patency of renal and visceral vessels after open thoracoabdominal aortic replacement.

2015

Objective In thoracoabdominal aortic aneurysms (TAAAs), a paradigm shift is observed from open surgery toward total endovascular aortic repair using fenestrated and branched endografts. Whereas outcome after open replacement in terms of mortality and paraplegia has been evaluated extensively, no studies exist addressing long-term patency of visceral and renal vessels. To enable comparison of target vessel patency between open and endovascular treatment, we analyzed our series of open TAAA replacements. Methods Our vascular surgery database was screened for patients who received open TAAA replacement between 1998 and 2012, and patient records were analyzed retrospectively. All available imag…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentKaplan-Meier EstimateRevascularizationAortographyMagnetic resonance angiographyAortic aneurysmBlood Vessel Prosthesis ImplantationRenal ArteryRisk Factorsmedicine.arterymedicineVascular PatencyHumansSuperior mesenteric arteryRenal arteryVascular PatencyAgedRetrospective Studiesmedicine.diagnostic_testAortic Aneurysm Thoracicbusiness.industryGraft Occlusion VascularVascular surgeryMiddle Agedmedicine.diseaseSurgeryVisceraTreatment OutcomeCardiothoracic surgerycardiovascular systemSurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedMagnetic Resonance AngiographyJournal of vascular surgery
researchProduct