Immediately provisionalized OsseoSpeed(™) Profile implants inserted into extraction sockets: 3-year results.
2015
Objectives A sloped shoulder might improve the congruence between extraction socket and dental implant and may add to a better circumferential support of the peri-implant structures. Therefore, this study evaluates the 3-year clinical outcome (survival and success rates, marginal bone levels, and Pink Esthetic Score (PES)) of immediately inserted and provisionalized OsseoSpeed(™) Profile implants in the anterior maxilla. Material and methods Twenty-one implants were inserted in 16 patients. All implants were immediately placed into extraction sites with and without facial bone deficiencies. A flapless procedure was utilized, and the implants were provisionalized immediately. Facial gaps wer…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Reconstruction of large mandibular and surrounding soft-tissue defects using distraction with bone transport.
2012
Reconstruction of large bone and soft-tissue defects of the inferior third of the face is possible using various surgical techniques. Patients who require these procedures need to be in good general health, may have sequelae linked to donor sites, and require several interventions to achieve good aesthetic and functional results. The aim of this study was to report outcomes in patients with large mandibular and soft-tissue defects treated using osteogenic distraction with bone transport. Between 2001 and 2008, 14 patients had distraction with bone transport. Most patients were men (92.1%). The mean age was 43.1 years. The average mandibular bone reconstruction was 13.6 cm. The mean duration…
Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
2011
Objectives: Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. Material and Methods: A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data we…
Immediate Implant Placement in Fresh Mandibular Molar Extraction Socket: 8-Year Results. A Case Report
2010
Abstract Recently, successful implant placement in fresh extraction sockets has been reported. In this case report, we present the results of an immediate implant placement in a fresh extraction socket of a mandibular molar with simultaneous bone regeneration using a nonresorbable membrane and no other graft materials. Clinical and radiographic findings acquired 8 years after implant placement demonstrated a stable peri-implant situation and confirmed a satisfactory treatment result.
Incidence of thromboembolic complications in patients with mechanical heart valves with a subtherapeutic international normalized ratio.
2008
Objective Subtherapeutic international normalized ratios are frequently encountered in clinical practice, and patients with mechanical heart valves with inadequate anticoagulation may be exposed to an increased risk of thromboembolic events. There are no data on thromboembolic event risk for these patients. Methods We assessed the current practice patterns in the management of patients with mechanical heart valves with subtherapeutic international normalized ratios and assessed the risk of thromboembolic complications in this setting. The charts of patients with mechanical heart valves followed up in two anticoagulation clinics were reviewed. Patients with a history of stable, therapeutic a…
Questionable Value of Adjuvant Arteriovenous Fistula in Pedal Bypass at High Risk for Early Failure
2007
Results of an adjuvant arteriovenous fistula (AVF) in pedal bypass surgery in the presence of poor status of the recipient artery, severely impaired intraoperative runoff, or revision for early failure and flow restitution were analyzed in a retrospective study. From January 1998 to December 2006, 24 adjuvant AVFs were constructed in autologous vein or composite pedal bypasses with low intraoperative bypass flow, poor status of the pedal artery, or during successful early bypass revision to prevent graft failure. All infrainguinal bypass operations were registered in a computerized database and prospectively followed. Pedal bypasses with adjunctive AVF were reviewed for fistula function, gr…
Cancer patients requiring interruption of long-term warfarin because of surgery or chemotherapy induced thrombocytopenia: The use of fixed sub-therap…
2012
No data are available regarding the management of cancer patients requiring interruption of long-term vitamin-K antagonist (VKA) therapy. For this purpose, we tested the efficacy and safety of fixed doses of low-molecular weight heparin (LMWH) in substitution of VKA because of invasive procedures or chemotherapy-induced thrombocytopenia. In cancer patients on VKA, therapy was discontinued 5 ± 1 days before surgery or chemotherapy. Heparin was given at prophylactic dosage in patients at low risk and at fixed subtherapeutic doses (3,800 or 4,000 UI anti-FXa, b.i.d.) in those at high-risk for thrombosis. LMWH was reinitiated 12 hr after surgery and VKA the day after. In patients receiving chem…
Histological differences in the adherence of connective tissue to laser-treated abutments and standard abutments for dental implants. An experimental…
2017
Background The goal of the current study is to assess the difference in connective tissue adherence to laser microtextured versus machined titanium abutments. Material and Methods Six patients were selected and each of them received 2 implants, one combined with a laser treated abutment and one with a machined abutment. After three months, the abutments were retrieved together with their surrounding gingival tissue for histological analysis. Qualitative and quantitative evaluation of microscopical images was performed to assess the presence or absence of adherence between the soft tissues and the abutment, and the percentage of soft tissue adhered to the two different surfaces. Results Inti…
Descriptive retrospective study analyzing relevant factors related to dental implant failure
2019
Background The objective of this retrospective descriptive study was to analyze the characteristics of incident reports provided by dentists while using a specific brand of dental implants. Material and Methods The study was carried out in collaboration with Oxtein Iberia S.L.®, with the company providing access to the incident database in order to evaluate the characteristics of incidents from January 2014 to December 2017 (a total of 917 over four years). The data sheet recorded different variables during each of the stages of implant treatment, from initial implant placement to subsequent prosthetic rehabilitation. These variables included age, sex, systemic pathologies, smoking habits, …