Search results for " radiography"
showing 10 items of 70 documents
Comparative study of the radiopacity of resin cements used in aesthetic dentistry
2015
PURPOSE. The aim of this study was to compare the radiopacity of 6 modern resin cements with that of human enamel and dentine using the Digora digital radiography system, to verify whether they meet the requirements of ANSI/ADA specification no. 27/1993 and the ISO 4049/2000 standard and assess whether their radiopacity is influenced by the thickness of the cement employed. MATERIALS AND METHODS. Three 3-thickness samples (0.5, 1 and 1.5 mm) were fabricated for each material. The individual cement samples were radiographed on the CCD sensor next to the aluminium wedge and the tooth samples. Five radiographs were made of each sample and therefore five readings of radiographic density were ta…
Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie
2004
Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…
Film and digital periapical radiographs for the measurement of apical root shortening
2012
Objectives: The aim of this study was to compare the accuracy and agreement of scanned film and digital periapical radiographs for the measurement of apical root shortening. Study design: Twenty-four film and digital [phosphor plate sensor (PPS)] periapical radiographs were taken using the long-cone paralleling technique for six extracted teeth before and after 1mm of apical root trimming. All teeth were mounted using a typodont and the radiographs were recorded using a film holder and polysiloxane occlusal index for each tooth to ensure standardization during the different radiographic exposures. The film radiographs were scanned and the tooth length measurements for the scanned film and d…
Trans-visceral migration of retained surgical gauze as a cause of intestinal obstruction: a case report
2008
AbstractIntroductionA retained surgical sponge in the abdomen is uncommon although it is likely that this finding is underreported in the medical literature. The intravisceral migration of retained surgical gauze is even rarer, as demonstrated by the very few cases reported.Case presentationThree years after undergoing anterior resection of the rectum, a 75-year-old man presented with symptoms of small bowel obstruction. Plain abdominal radiography and CT showed a radio-opaque marker; a foreign body was suspected, probably a piece of retained surgical gauze. An ileotomy of about 5 cm. was performed to confirm this diagnosis and remove the gauze.ConclusionAlthough rare, retained gauze in the…
Effect of antibiotic prophylaxis for preventing infectious complications following impacted mandibular third molar surgery. A randomized controlled t…
2021
Background The objective of this study was to determine the effect of antibiotic prophylaxis in preventing postoperative infections after extraction of impacted mandibular third molars. Material and Methods A Parallel-group, randomized, blind, placebo-controlled trial was performed. 154 patients were randomly allocated to 2 groups; experimental (n=77) receiving 2g amoxicillin 1 hour prior to surgery and control (n=77) receiving placebo. Primary outcome was postoperative infections and secondary outcome was the need for rescue analgesia. Results 4.5% of patients developed postoperative infections, five patients of the control group (4 alveolar osteitis, 1 surgical site infection) and two of …
Radiographic technical quality of root canal treatment performed ex vivo by dental students at Valencia University Medical and Dental School, Spain
2013
Objectives: To evaluate radiographically the quality of root canal fillings and compare manual and rotary preparation performed on extracted teeth by undergraduate dental students. Study Design: A total of 561 premolars and molars extracted teeth were prepared using nickel-titanium rotary files or manual instrumentation and filled with gutta-percha using a cold lateral condensation technique, by 4th grade undergraduate students. Periapical radiographs were used to assess the technical quality of the root canal filling, evaluating three variables: length, density and taper. These data were recorded, scored and used to study the “technical success rate” and the “overall score”. The length of …
Diagnostic Validity of Digital Imaging Fiber-Optic Transillumination (DIFOTI) and Near-Infrared Light Transillumination (NILT) for Caries in Dentine.
2020
The objective of the study is to analyse the available evidence for the validity of the transillumination method in the diagnosis of interproximal caries. Bibliographic searches were carried out in three data bases (PubMed, Embase, Scopus) with the key words “Transillumination AND caries”. A total of 11 studies were selected for the qualitative analysis and meta-analysis. In the qualitative analysis, both in vivo and in vitro studies were included. The gold standards were tomography, digital radiography, and clinical visual diagnosis. The meta-analysis determined the sensitivity, specificity, and area below the ROC curve relative to the transillumination method in the diagnosis …
Evaluation of a digital radiography to estimate working length
1997
The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulte…
Comparison of diagnostic accuracy between periapical and panoramic radiographs and cone beam computed tomography in measuring the periapical area of …
2019
Background The aim of the study was compare the sensitivity and measurements obtained from teeth with apical lesions scheduled for periapical surgery using three different diagnostic methods: periapical radiography (Gendex Expert DC), panoramic radiography (Planmeca® Promax 3D Classic) and cone beam computed tomography (CBCT) (Planmeca® Promax 3D Classic). Material and methods This cross-sectional study involved 35 patients (45 teeth) scheduled for periapical surgery in which periapical radiographs, panoramic radiographs and CBCT scans had been obtained. The images were used to analyze the maximum vertical and horizontal dimension and the resulting areas of the periapical lesions based on t…
The evaluation of root fracture with cone beam computed tomography (CBCT) : an epidemiological study
2018
Background The aim of this study was evaluation of the cone-beam computed tomography (CBCT) image of 50 patients at the ages of 8-15 suspecting root fracture and root fracture occurred, exposed to dental traumatic. In additionally, this study was showed effect of crown fracture on root fracture healing. Material and methods All of the individuals included in the study were obtained images with the cone-beam computed tomography range of 0,3 voxel and 8.9 seconds.(i-CAT®, Model 17-19, Imaging SciencesInternational, Hatfield, Pa USA).The information obtained from the history and CBCT images of patients were evaluated using chi-square test statistical method the mean and the distribution of the…