Search results for " resin"

showing 10 items of 268 documents

Solid state NMR investigation of the roman Acqualadroni rostrum: tenth year assessment of the consolidation treatment of the wooden part

2020

Abstract: This work follows a previous one dealing with the state of conservation study of the wooden part of the roman Acqualadroni rostrum soon after its finding in the seabed of Acqualadroni (Messina, Italy). The archaeological survey and recovery were particularly relevant since this artefact is one of the two rostrums, nowadays known,found together with its wooden part. Following the recovery, it was consolidated by immersion in a melamine-formaldehyde resin (Kauramin) aqueous solution for eight months at the “Centro di Restauro del Legno Bagnato” (Pisa, Italy). The present investigation is aimed to determine at microscopic scale the wood state of conservation and to highlight interact…

Conservation treatmentMaterials sciencePolymers and PlasticsConsolidation (soil)Contact timeRostrumMineralogy02 engineering and technologyNuclear magnetic resonance spectroscopy010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesCoring0104 chemical scienceschemistry.chemical_compoundSolid-state nuclear magnetic resonancechemistryMelamine-formaldehyde resinMagic angle spinningLigninMicroscopic structure0210 nano-technologyWaterlogged wood
researchProduct

Determinazione di componenti della vernice e della colla del contrabbasso “Panormo” di Vincenzo Trusiano

2007

Contrabbasso Derivatizzazione GC Legante Vernice Acidi grassi Amino acidi ResineSettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni Culturali
researchProduct

The cytotoxicity of resin composites cured with three light curing units at different curing distances.

2011

Objective: The purpose of this study was to compare the effect of light curing distance on the cytotoxicity of five resin composites cured with three high-power light curing units. Study design: Seven cylindrical discs of each material (Grandio ®, Voco; Filtek ? Z250, 3M ESPE; Clearfil ? AP-X, Kuraray Co. Ltd.; Aelite ? LS, Bisco Inc. and Simile ®, Pentron) were cured. For curing, soft-up mode of quartz-tungsten-halogen, exponential mode of light emitting diode for 20 s, and ramp-curing mode of plasma arc light curing units for 6 s were used. The curing tip distances were determined as 2 and 9 mm and controlled via the use of metal rings. After ageing the samples for 24 and 72 hours in Dulb…

Curing Lights DentalMaterials scienceBiocompatibilityResin compositeSignificant differenceFibroblasts:CIENCIAS MÉDICAS [UNESCO]Composite ResinsLight curingMiceOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASToxicity TestsAnimalsSurgeryMouse FibroblastEvaluation periodCytotoxicityGeneral DentistryCuring (chemistry)Nuclear chemistryMedicina oral, patologia oral y cirugia bucal
researchProduct

Effect of cyclic loading on fracture strength and microleakage of a quartz fiber dowel with different adhesive, cement and resin core material combin…

2010

Background: This study evaluated the performance of different adhesive-cement-core combinations coupled with quartz fiber dowels after cyclic loading and fracture strength tests and assessed the microleakage using dye penetration method. Methods: Forty maxillary canines (n=10 per group) were restored with fiber dowels (Quartz fiber DT Light Post) and four adhesive-cement-core material combinations [(Group 1: All-Bond 2+C&B (root) / All-Bond 2+Biscore (core); Group 2: All-Bond 2+Bisfil 2B (root) / All-Bond 2+Bisfil 2B (core); Group 3: Scotchbond 1+RelyX ARC (root) / Scotchbond 1+Supreme (core); Group 4: RelyX Unicem (root) / Scotchbond 1+Filtek Supreme (core)]. The specimens were initially c…

CuspidDental CementsEquipment DesignQuartzCyclic loading Fiber dowels Fracture strength MicroleakageComposite ResinsPermeabilityPolyethylene GlycolsResin CementsWeight-BearingResins SyntheticPolymethacrylic AcidsSettore MED/28 - Malattie OdontostomatologicheDentin-Bonding AgentsMaterials TestingMethacrylatesBisphenol A-Glycidyl MethacrylateEquipment FailureStress MechanicalPost and Core Technique
researchProduct

Evaluation of marginal leakage after mechanical fatigue cycling of composite inlays luted with different cements

2018

This in vitro study evaluated the marginal microleakage of composite inlays luted with 3 different cement systems. The null hypothesis was that the luting materials would not influence dye penetration, showing the same degree of microleakage. Thirty-six sound molars were selected, mesio-occlusodistal cavities were prepared, and the teeth were randomly divided into 3 groups (n = 12). Composite resin inlay restorations were made and cemented using a dual-curing resin cement (Calibra), a light-curing flowable composite (Charisma Flow), or a self-adhesive resin cement (RelyX Unicem). The restored teeth were subjected to fatigue cycles and immersed in 0.5% basic fuchsin dye for 24 hours. Two ort…

Dental Leakagedental restorationIn Vitro TechniqueDental CementscementationIn Vitro TechniquesComposite ResinComposite ResinsMolarResin CementsInlaySettore MED/28 - Malattie OdontostomatologicheInlaysresin cementHumansDental Restoration FailureDental CementHuman
researchProduct

Determination of polymerization shrinkage stress by means of a photoelastic investigation

2002

This study examined the polymerization stress of different established composite resins (Tetric Ceram, Vivadent; EsthetX, Surefil, Dentsply/DeTrey; Clearfil AP-X, Clearfil Photo Posterior, Kuraray; Prodigy Condensable, sds Kerr; Filtek P 60, 3M ESPE; Solitaire 2, Heraeus-Kulzer) by means of a photo-elastic investigation and investigated six new, experimental composite resins, which have been claimed to exhibit less polymerization shrinkage (InTen-S, Vivadent; K 112, K 051, Dentsply/DeTrey; Compox, Pluto, Hermes 3M ESPE).Cylindrical cavities (phi 5 mm) in Araldit B epoxide resin plates (40 x 40 x 3 mm3) were pretreated with the Rocatec system to ensure bonding of the composite resin. Ten com…

Dental Stress AnalysisBirefringenceMaterials scienceLightMolecular StructurePolymersComposite numberFirst orderComposite ResinsElasticityPhase TransitionStress (mechanics)PolymerizationMechanics of MaterialsTetric ceramMaterials TestingGeneral Materials ScienceStatistical analysisStress MechanicalComposite materialGeneral DentistryShrinkageDental Materials
researchProduct

Retentive strengths of cast gold crowns using glass ionomer, compomer, or resin cement

1998

The retention forces of a newly developed compomer cement (Dyract Cem), a glass ionomer cement (Ketac Cem Aplicap), and a resin cement (F21) were examined.Cemented cast gold crowns were removed along the path of insertion with a Zwick universal testing device. The impact of both a cured and a noncured additional bonding layer that were applied to the inner surface of the crowns was examined across the Dyract Cem group.The mean adhesive strength was measured at 2.36 +/- 0.69 N/mm2 in the Ketac Cem group, at 0.60 +/- 0.28 N/mm2 in the F21 group, and at 1.85 +/- 0.94 N/mm2 in the Dyract Cem group, respectively. The application of an additional bonding layer to the inner surface of the crowns d…

Dental Stress AnalysisMaterials scienceSurface PropertiesPolyestersGlass ionomer cementDental CementsComposite ResinsDental Prosthesis RetentionAdhesion strengthHumansComposite materialCementationResin cementCementPolycarboxylate CementCrownsCompomersSilicatesDental BondingAdhesivenessResin CementsDyract-cemGlass Ionomer CementsDentinGold AlloysMethacrylatesStress MechanicalZinc OxideOral SurgeryMagnesium OxideThe Journal of Prosthetic Dentistry
researchProduct

Bond strength and internal adaptation of customized glass fiber posts using different bulk-fill flow resins

2022

Made available in DSpace on 2022-04-29T08:40:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2022-03-01 Background: this study aimed to evaluate the bond strength and internal adaptation of customized glass fiber posts using Bulk Fill flowable composite resins (BF) and conventional composite resin. Materials and Methods: Fifty bovine teeth were randomly divided (n=10) according to the following groups: G1 (control): glass fiber posts were adapted to the root canal and luted with Rely-X ARC cement (3M® ESPE); G2: fiber posts smaller than the root canal diameter were customized using Filtek™ Z350 XT (3M® ESPE) conventional composite resin, and luted similarly to Group 1. G3: posts were c…

Dental pulpGlass fiber postFiber postsComposite resinsGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…

2020

Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…

Dental softwarebusiness.industryComputer scienceMouth RehabilitationIntervention approachDentistryCAD030206 dentistryComposite ResinsDental Porcelain03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental Prosthesis DesignVirtual imageTooth wearDental Prosthesis DesignComputer-Aided DesignHumansTooth WearOral SurgeryMouth RehabilitationbusinessThe Journal of prosthetic dentistry
researchProduct

Determination of glyphosate and aminomethylphosphonic acid in natural water using the capillary electrophoresis combined with enrichment step

2005

A previously elaborated capillary electrophoresis (CE) method used for the determination of glyphosate and aminomethylphosphonic acid (AMPA) was slightly modified in order to improve the sensitivity. However, detection limits attained (5 μg mL−1 for glyphosate and 4 μg mL−1 for AMPA) were still not satisfactory for analytical purposes, thus the addition of a preconcentration step before the CE analysis was proposed. AMBERLITE®IRA-900, a strong anion-exchange resin, was used to preconcentrate both analytes in environmental aqueous samples. The experimental conditions optimised in a previous work were readapted, by decreasing the eluent concentration due to CE limitations. Satisfactory result…

Detection limitaminomethylphosphonic acid (AMPA)Chromatographyanion-exchange resinsChemistrycapillary electrophoresisBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresisglyphosateGlyphosateenvironmental analysisUltrapure waterEnvironmental ChemistryAminomethylphosphonic acidSample preparationHPLCSpectroscopyAnalytica Chimica Acta
researchProduct