Search results for " sensitivity"
showing 10 items of 947 documents
Diurnal variations in visual performance for disposable contact lenses.
2013
The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
2021
Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …
Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions
2014
To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare.In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; BauschLomb], Acuvue Oasys for Presbyopia [AOP; JohnsonJohnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wear…
Health anxiety and attentional bias: the time course of vigilance and avoidance in light of pictorial illness information.
2011
Cognitive-behavioral models of health anxiety stress the importance of selective attention not only towards internal but also towards external health threat related stimuli. Yet, little is known about the time course of this attentional bias. The current study investigates threat related attentional bias in participants with varying degrees of health anxiety. Attentional bias was assessed using a visual dot-probe task with health-threat and neutral pictures at two exposure durations, 175ms and 500ms. A baseline condition was added to the dot-probe task to dissociate indices of vigilance towards threat and difficulties to disengage from threat. Substantial positive correlations of health anx…
Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad
2015
[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…
Antibacterial susceptibility patterns of Porphyromonas gingivalis isolated from chronic Periodontitis patients
2010
Objectives: To test the antimicrobial sensitivity of Porphyromonas gingivalis to a panel of eight orally administrable antibiotics in chronic periodontal diseases and to evaluate factors associated with periodontitis in adult patients. Study Design: A total of fifty strains of P. gingivalis were isolated from one hundred and twenty adult patients with chronic perio-dontitis. Identification of bacteria was carried out by anaerobic culture and biochemical tests. Selected colonies of P. gingivalis were used to evaluate the antibacterial activities of penicillin, metronidazole, amoxicillin, amoxicillin/clavulanic acid, clindamycin, doxy-cycline, ciprofloxacin and azithromycin. Results: Most of …
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
2012
Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…
Diagnostic performance of qualitative and radiomics approach to parotid gland tumors: which is the added benefit of texture analysis?
2021
Objective: To investigate whether MRI-based texture analysis improves diagnostic performance for the diagnosis of parotid gland tumors compared to conventional radiological approach. Methods: Patients with parotid gland tumors who underwent salivary glands MRI between 2008 and 2019 were retrospectively selected. MRI analysis included a qualitative assessment by two radiologists (one of which subspecialized on head and neck imaging), and texture analysis on various sequences. Diagnostic performances including sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of qualitative features, radiologists’ diagnosis, and radiomic models were evaluated. Result…
Anxiety sensitivity as predictor of pain in patients undergoing restorative dental procedures
2006
Abstract – Objectives: The personality disposition to anxiety sensitivity refers to beliefs about negative consequences of bodily arousal. The concept has recently been successfully applied in research on chronic pain conditions. The present study investigated whether anxiety sensitivity interacts with dental fear to increase expected and experienced pain during routine dental treatment. Methods: Subjects were 97 patients undergoing dental procedures of excavation and filling. Anxiety dispositions were measured by the Anxiety Sensitivity Index and the Dental Anxiety Scale. Expected and experienced pain were assessed by affective and sensory verbal descriptor scales and a numerical rating…
Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.
2009
To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …