Search results for " sensor"
showing 10 items of 1714 documents
A device for multimodal imaging of skin
2013
A compact prototype device for diagnostic imaging of skin has been developed and tested. Polarized LED light at several spectral regions is used for illumination, and round skin spot of diameter 30mm is imaged by a CMOS sensor via crossoriented polarizing filter. Four consecutive imaging series are performed: (1) RGB image at white LED illumination for revealing subcutaneous structures; (2) four spectral images at narrowband LED illumination (450nm, 540nm, 660nm, 940nm) for mapping of the main skin chromophores; (3) video-imaging under green LED illumination for mapping of skin blood perfusion; (4) autofluorescence video-imaging under UV (365nm) LED irradiation for mapping of the skin fluor…
Comparison of different predictive models for nutrient estimation in a sequencing batch reactor for wastewater treatment
2006
Abstract In this paper different predictive models for nutrient estimation in a sequencing batch reactor (SBR) for wastewater treatment are compared: principal component regression (PCR), partial least squares (PLS), and artificial neural networks (ANNs). Two unfolding procedures were used: batch-wise and variable-wise. For the latter unfolding method, X and Y matrix augmentation with lagged variables were used in some models to incorporate process dynamics. The results have shown that batch-wise unfolding PLS models outperform the other approaches. The ANN models are good predictive models, but in this particular case-study, they do not outperform those multivariate projection models that …
Visually low-impacting methods for the measurement of parameters related to IAQ risk indicators in exhibition halls
2021
Microclimate for cultural heritage plays a fundamental role in the degradation process of artefacts exhibited in museums. Generally, the Indoor Air Quality (IAQ) monitoring inside museums is based on conventional measurements of thermo-hygrometry parameters and longtime averaged measurements of atmospheric pollutants’ concentration. Unfortunately, all these approaches require electric supply and are usually characterized by a noticeable visual impact on the exhibition space, which clearly negatively affects the visitors’ experience. This paper intends to revisit and discuss a methodology (and its test application on field, to estimate the risk of damage of three artefacts displayed in an ol…
A Novel CCT5 Missense Variant Associated with Early Onset Motor Neuropathy
2020
Diseases associated with acquired or genetic defects in members of the chaperoning system (CS) are increasingly found and have been collectively termed chaperonopathies. Illustrative instances of genetic chaperonopathies involve the genes for chaperonins of Groups I (e.g., Heat shock protein 60, Hsp60) and II (e.g., Chaperonin Containing T-Complex polypeptide 1, CCT). Examples of the former are hypomyelinating leukodystrophy 4 (HLD4 or MitCHAP60) and hereditary spastic paraplegia (SPG13). A distal sensory mutilating neuropathy has been linked to a mutation [p.(His147Arg)] in subunit 5 of the CCT5 gene. Here, we describe a new possibly pathogenic variant [p.(Leu224Val)] of the same subunit b…
Risk Factors for Sensorineural Hearing Loss and Auditory Maturation in Children Admitted to Neonatal Intensive Care Units: Who Recovered?
2022
Background: Newborns admitted to neonatal intensive care units (NICUs) are at higher risk of developing sensorineural hearing loss (SNHL), which may improve over time. The aim of this study was to describe the prevalence of the main risk factors for SNHL in a NICU cohort, focusing on children who underwent auditory maturation. Methods: An observational study of 378 children admitted to NICUs, who were followed for at least 18 months, with periodic audiologic assessments. Results: Out of 378 patients, 338 had normal hearing and 40 were hearing-impaired; we found a higher percentage of extremely preterm (EPT) and extremely low-birthweight (ELBW) infants in SNHL children (p < 0.05). Sevente…
Development of Durum Wheat Breads Low in Sodium Using a Natural Low-Sodium Sea Salt
2020
Durum wheat is widespread in the Mediterranean area, mainly in southern Italy, where traditional durum wheat breadmaking is consolidated. Bread is often prepared by adding a lot of salt to the dough. However, evidence suggests that excessive salt in a diet is a disease risk factor. The aim of this work is to study the effect of a natural low-sodium sea salt (Saltwell®
A 3.3 V Output Voltage Optical Plasmonic Solar Energy Harvester
2021
In this paper, for the first time, the design of a solar energy-harvester (EH) based on plasmonic optical nanorectennas and without the step-up converter is presented. The novel optical harvester with a 49497∗14286 nanoarray of about 21,21 mm2 presents an output voltage value of 3.3 V and an output current of 10 mA.
Fourth‐generation glucose sensors composed of copper nanostructures for diabetes management: A critical review
2022
Abstract More than five decades have been invested in understanding glucose biosensors. Yet, this immensely versatile field has continued to gain attention from the scientific world to better understand and diagnose diabetes. However, such extensive work done to improve glucose sensing devices has still not yielded desirable results. Drawbacks like the necessity of the invasive finger‐pricking step and the lack of optimization of diagnostic interventions still need to be considered to improve the testing process of diabetic patients. To upgrade the glucose‐sensing devices and reduce the number of intermediary steps during glucose measurement, fourth‐generation glucose sensors (FGGS) have be…
A Novel Gas Sensor Transducer Based on Phthalocyanine Heterojunction Devices
2007
Abstract: Experimental data concerning the changes in the current-voltage (I-V) perfor-mances of a molecular material-based heterojunction consisting of hexadecafluorinated nickel phthalocyanine (Ni(F 16 Pc)) and nickel phthalocyanine (NiPc), (Au|Ni(F 16 Pc)|NiPc|Al) are introduced as an unprecedented principle of transduction for gas sensing performances. The respective n - and p -type doped-insulator behaviors of the respective materials are supported, owing to the observed changes in surface potential (using the Kelvin probe method) after submission to electron donor (ammonia) and electron acceptor gases (ozone). On the other hand, the bilayer device exhibits strong variations in the bui…