Search results for " spread"

showing 10 items of 241 documents

Quasi-isotropic 3-D resolution in two-photon scanning microscopy.

2009

One of the main challenges in three-dimensional microscopy is to overcome the lack of isotropy of the spatial resolution, which results from the axially-elongated shape of the point spread function. Such anisotropy gives rise to images in which significant axially-oriented structures of the sample are not resolved. In this paper we achieve an important improvement in z resolution in two-photon excitation microscopy through spatial modulation of the incident beam. Specifically, we demonstrate that the design and implementation of a simple shaded ring performs quasi-isotropic three-dimensional imaging and that the corresponding loss in luminosity can be easily compensated by most available fe…

PhysicsPoint spread functionbusiness.industryIsotropyResolution (electron density)Physics::OpticsAtomic and Molecular Physics and OpticsOpticsTwo-photon excitation microscopyMicroscopyFemtosecondNear-field scanning optical microscopebusinessImage resolutionOptics express
researchProduct

Three-dimensional point spread function of multilayered flat lenses and its application to extreme subwavelength resolution

2011

The three-dimensional (3D) point spread function (PSF) of multilayered flat lenses was proposed in order to characterize the diffractive behavior of these subwavelength image formers. We computed the polarization-dependent scalar 3D PSF for a wide range of slab widths and for different dissipative metamaterials. In terms similar to the Rayleigh criterion we determined unambiguously the limit of resolution featuring this type of image-forming device. We investigated the significant reduction of the limit of resolution by increasing the number of layers, which may drop nearly 1 order of magnitude. However, this super-resolving effect is obtained in detriment of reducing the depth of field. Li…

PhysicsPoint spread functionbusiness.industryScalar (physics)Physics::OpticsMetamaterialCondensed Matter PhysicsElectronic Optical and Magnetic Materialssymbols.namesakeOpticsOptical transfer functionsymbolsDepth of fieldRayleigh scatteringbusinessImage resolutionOrder of magnitudeJournal of Nanophotonics
researchProduct

Time-of-arrival, angle-of-arrival, and angle-of-departure statistics of a novel simplistic disk channel model

2011

This paper introduces a novel simplistic geometrical disk scattering model in which the local scatterers are uniformly distributed in polar coordinates within a disk centered on the mobile station (MS). The proposed joint uniform distribution in polar coordinates results in a higher concentration of scatterers around the disk center and a lower concentration far from it. Furthermore, it is assumed that the base station (BS) is elevated to a non-scattering region and that a wave transmitted from the BS reaches the MS after a single bounce by one of the randomly distributed scatterers. Under the above-mentioned assumptions, we derive closed-form expressions for the joint probability density f…

PhysicsUniform distribution (continuous)Time of arrivalbusiness.industryJoint probability distributionAngle of arrivalMobile stationMathematical analysisProbability density functionPolar coordinate systemTelecommunicationsbusinessDelay spread2011 5th International Conference on Signal Processing and Communication Systems (ICSPCS)
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

The INTEGRAL IBIS/ISGRI System Point Spread Function and Source Location Accuracy

2003

The imager on board INTEGRAL (IBIS) presently provides the most detailed sky images ever obtained at energies above 30 keV. The telescope is based on a coded aperture imaging system which allows to obtain sky images in a large field of view 29deg x 29deg with an angular resolution of 12'. The System Point Spread Function of the telescope and its detailed characteristics are here described along with the specific analysis algorithms used to derive the accurate point-like source locations. The derived location accuracy is studied using the first in-flight calibration data on strong sources for the IBIS/ISGRI system. The dependence of the calibrated location accuracy with the signal to noise r…

Point spread functionAstrophysics::High Energy Astrophysical PhenomenaData analysisFOS: Physical sciencesImage processingField of viewAstrophysicsAstrophysicsUNESCO::ASTRONOMÍA Y ASTROFÍSICAlaw.inventionTelescopeHigh angular resolutionSignal-to-noise ratioImage processinglawData analysis ; Image processing ; High angular resolutionAngular resolutionCoded aperture:ASTRONOMÍA Y ASTROFÍSICA::Astronomía óptica [UNESCO]Remote sensingIbisPhysicsbiologyUNESCO::ASTRONOMÍA Y ASTROFÍSICA::Astronomía ópticaAstrophysics (astro-ph)Astrophysics::Instrumentation and Methods for AstrophysicsAstronomy and Astrophysicsbiology.organism_classificationSpace and Planetary Science:ASTRONOMÍA Y ASTROFÍSICA [UNESCO]
researchProduct

Color difference threshold of chromostereopsis induced by flat display emission

2015

The study of chromostereopsis has gained attention in the backdrop of the use of computer displays in daily life. In this context, we analyze the illusory depth sense using planar color images presented on a computer screen. We determine the color difference threshold required to induce an illusory sense of depth psychometrically using a constant stimuli paradigm. Isoluminant stimuli are presented on a computer screen, which stimuli are aligned along the blue–red line in the computer display CIE xyY color space. Stereo disparity is generated by increasing the color difference between the central and surrounding areas of the stimuli with both areas consisting of random dots on a black backgr…

Point spread functionChromostereopsisstereo disparityColor differencePixelgenetic structuresbusiness.industrylcsh:BF1-990eye chromatic aberrationsContext (language use)Pupilfusion of retinal imageslcsh:PsychologyPlanarperception thresholdColor chartPsychologychromostereopsisComputer visionArtificial intelligenceStereodisparitybusinessPsychologyGeneral PsychologyOriginal ResearchFrontiers in Psychology
researchProduct

Superresolved imaging of remote moving targets.

2006

We present a superresolving approach that allows one to exceed the diffraction limit and recover highly resolved contours of moving targets from a sequence of low-resolution images. The presented approach is suitable for remote sensing applications. The resolution decoding algorithm that is used to recover the high-resolution features of the target can be run partially via optical means and that way can be used to reduce the required computational complexity.

Point spread functionComputational complexity theorybusiness.industryComputer scienceRemote sensing applicationMovementComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONVideo RecordingInformation Storage and RetrievalReproducibility of ResultsImage processingIterative reconstructionImage EnhancementSensitivity and SpecificityAtomic and Molecular Physics and OpticsPattern Recognition AutomatedOpticsSubtraction TechniqueImage Interpretation Computer-AssistedPhotographyLimit (mathematics)businessImage resolutionDecoding methodsAlgorithmsOptics letters
researchProduct

One-dimensional iterative algorithm for three-dimensional point-spread function engineering.

2001

We present a new method with which to binarize pupil filters designed to control the three-dimensional irradiance distribution in the focal volume of an optical system. The method is based on a one-dimensional iterative algorithm, which results in efficient use of computation time and in simple, easy to fabricate binary filters. An acceptable degree of resemblance between the point-spread function of the annular binary filter and that of its gray-tone counterpart is obtained.

Point spread functionComputer scienceIterative methodbusiness.industryComputationFast Fourier transformComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONBinary numberFilter (signal processing)Function (mathematics)Atomic and Molecular Physics and OpticsOpticsOptical filterbusinessOptics letters
researchProduct

Lightfield microscopy, an emerging tool for real-time 3D imaging

2020

Integral, or lightfield, microscopy offers the possibility of capturing and processing in real time multiple views of 3D fluorescent samples captured with a single shot. In this contribution we review the recent advances in lightfield microscopy and enunciate the forthcoming challenges.

Point spread functionComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSingle shotIntegral photographyGeneralLiterature_MISCELLANEOUSlaw.inventionOpticsConfocal microscopylawMicroscopybusinessMultiple viewImaging and Applied Optics Congress
researchProduct