Search results for " suture"

showing 9 items of 39 documents

A stereotactic device for rabbits based on mandibular and cranial landmarks

2008

✓ The authors have developed a stereotactic device for use in rabbits that uses the plane at the base of the mandible combined with cranial sutures as an anatomical reference. The device was developed for a study designed to evaluate catheters for infection prophylaxis, and this required the implantation of silicone catheters along a reproducible trajectory through the lateral ventricle. Cadaver and atlas studies demonstrated consistent spatial relationships between intracranial structures and the surface plane on which the animals were resting during the surgery. This plane is formed by the 2 mandibular angles and the mandibular tip. The authors developed a stainless steel stereotactic dev…

Stereotactic surgerybusiness.industryTechnical noteCranial SuturesEquipment DesignMandibleGeneral MedicineHead fixationAnatomyCerebrospinal Fluid ShuntsSagittal planeCatheterizationStereotaxic Techniquesmedicine.anatomical_structureCadaverCoronal planeCranial suturesMandibular planeAnimalsMedicineFemaleRabbitsbusinessBiomedical engineeringJournal of Neurosurgery
researchProduct

Biomechanical comparison between the modified rolling-hitch and the modified finger-trap suture techniques

2016

Purpose: The purpose of this study was to characterize the biomechanical effect of two grasping suture techniques used during ligament reconstruction: the modified rolling-hitch (MRH) and the modified finger-trap (MFT). Methods: Flexor profundus tendons were harvested from fresh pig hind-leg trotters. Each specimen was mounted on an electro-mechanic universal testing machine (Instron 3367). In half of all tendons (15 specimens), the suture was passed around the tendon following the MRH knot (Group 1). In the remaining half of all tendons (15 specimens), the suture was passed over a distance of 30 mm according to the MFT suture technique (Group 2). As per standard intra-operative technique, …

SwineTendons03 medical and health sciences0302 clinical medicineSuture (anatomy)Finger InjuriesSettore MED/33 - Malattie Apparato LocomotoremedicineAnimalsOrthopedics and Sports MedicineOrthodontics030222 orthopedicsUniversal testing machineSuturesbusiness.industrySuture TechniquesSignificant differenceStiffness030229 sport sciencesGeneral MedicinePlastic Surgery ProceduresTendonmedicine.anatomical_structureLigamentSurgerymedicine.symptomMFT modified finger-trap grasping suture tendon suture suture ligament reconstructionbusinessArchives of Orthopaedic and Trauma Surgery
researchProduct

Renal transplantation by automatic anastomotic device in a porcine model

2015

Automatic vascular staplers for vascular anastomoses in kidney transplantation may dramatically reduce the operative time and, in particular, warm ischemia time, thus increasing the outcome of transplantation. Ten pigs underwent kidney auto-transplantation by automatic anastomotic device. Kidneys were collected by laparotomy with selective ligations at the renal hilum and perfused with cold storage solution. To overcome the shortage in length of renal hilum, a tract of the internal jugular vein was harvested to increase the length of the vessels. The anastomoses were totally performed by the use of the anastomotic device. On 10 kidney transplants, nine were successful and no complications o…

Vascular anastomosiAnastomosis deviceAnimalSwineMedicine (all)Anastomosis SurgicalBiomedical EngineeringMedicine (miscellaneous)Mechanical vascular sutureWarm ischemia timeBioengineeringKidneyIliac ArteryKidney TransplantationBiomaterialAnastomosis device; Kidney transplantation; Mechanical vascular sutures; Vascular anastomosis; Warm ischemia time; Anastomosis Surgical; Animals; Automation; Disease Models Animal; Female; Iliac Artery; Kidney; Kidney Transplantation; Renal Artery; Swine; Biomaterials; Biomedical Engineering; Bioengineering; Medicine (miscellaneous); Medicine (all)AutomationDisease Models AnimalSettore MED/18 - Chirurgia GeneraleRenal ArteryAnimalsFemale
researchProduct

Endoscopic transventricular third ventriculostomy through the lamina terminalis

2010

Object Endoscopic third ventriculostomy (ETV) has become a well-accepted option for obstructive hydrocephalus. However, standard ventriculostomy at the floor of the third ventricle might not be feasible under certain conditions. Here, the authors report in detail on their initial experience with an alternative option of endoscopic ventriculostomy through the lamina terminalis via a transventricular route. Methods Endoscopic third ventriculostomy through the lamina terminalis from a transventricular transforaminal route was evaluated in 4 cadaveric human heads and in 4 clinical cases. Results In all 4 human cadavers, an opening of the lamina terminalis via a transventricular approach could …

Ventriculostomymedicine.medical_specialtyThird ventriclemedicine.diagnostic_testLamina terminalisbusiness.industrymedicine.medical_treatmentEndoscopic third ventriculostomyTransventricularOptic chiasmGeneral MedicineAnatomySurgeryEndoscopymedicine.anatomical_structureMedicineCoronal suturebusinessJournal of Neurosurgery
researchProduct

Eight-point compass rose underlay technique in 72 consecutive elderly patients with large incisional hernia

2011

Summary Background Repair of incisional hernia (IH) in the elderly is a challenge for the surgeon. Primary closure is preferable but is not always possible because of high recurrence rates of IH repaired without a prosthesis and/or possible respiratory and cardiovascular complications due to extreme tension of the margins. We report our experience with underlay mesh placement in elderly patients with large IH. Methods A total of 72 patients from January 2003 to December 2009 underwent IH repair involving placement of an intraperitoneal Gore® DualMesh® prosthesis. The prosthesis was first anchored at eight points in a compass rose pattern using a Gore® suture passer and then firmly secured t…

medicine.medical_specialtyIncisional herniamedicine.medical_treatmentHigh-risk elderly patientAdhesion (medicine)lcsh:GeriatricsProsthesisePTFE meshTension-free techniqueAbdominal wallLarge ventral herniaSuture (anatomy)PneumoperitoneumePTFE mesh; High-risk elderly patients; Large ventral hernia; Suture passer; Tension-free techniquemedicineLaparoscopyhigh-risk elderly patientsSuture passermedicine.diagnostic_testbusiness.industrymedicine.diseaseSurgeryDissectionlcsh:RC952-954.6Settore MED/18 - Chirurgia Generalemedicine.anatomical_structureGeriatrics and Gerontologybusiness
researchProduct

A Continuous Suture Anastomosis Outperforms a Simple Interrupted Suture Anastomosis in Esophageal Elongation.

2020

Abstract Introduction Long-gap esophageal atresia represents a distinct entity among the esophageal atresia spectrum. In many patients, achieving a reasonable anastomosis depends on some millimeters of tissue. We aimed to determine what effect the suturing technique would have on esophageal ex vivo elongation as it may determine the strength of a primary anastomosis. Materials and Methods In an analysis of porcine esophagi from animals for slaughter (100–120 days old with a weight of 100–120 kg), we determined esophageal length gain of simple continuous and simple interrupted suture anastomoses subjected to linear traction until linear breaking strength was reached. Statistical power of 80%…

medicine.medical_specialtySwineAnastomosisBreaking strength03 medical and health sciences0302 clinical medicineEsophagus030225 pediatricsTensile StrengthMedicineAnimalsHumansEsophageal Atresiabusiness.industryPrimary anastomosisAnastomosis SurgicalSuture Techniquesmedicine.diseaseConfidence intervalSurgery030220 oncology & carcinogenesisAtresiaPediatrics Perinatology and Child HealthSurgerybusinessContinuous sutureEuropean journal of pediatric surgery : official journal of Austrian Association of Pediatric Surgery ... [et al] = Zeitschrift fur Kinderchirurgie
researchProduct

Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair

2017

Purpose: To investigate the effect of applying an additional suture to enhance the biomechanical behavior of the suture–meniscus construct used during the transtibial pull- out repair technique. Methods: A total of 20 fresh-frozen porcine tibiae with intact medial menisci were used. In one half of all speci- mens (N = 10), two non-absorbable sutures were passed directly over the meniscal root from the tibia side of the meniscus to the femoral side (2SS). In other ten specimens, three sutures were passed over the meniscal root (3SS). All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement of the construct was recorded at 100, 500, and 1000 cycles. Fur…

medicine.medical_specialtyUltimate loadSwineMenisci Tibial03 medical and health sciences0302 clinical medicineSettore MED/33 - Malattie Apparato LocomotoremedicineAnimalsCyclic loadingOrthopedics and Sports Medicinemeniscal root repair meniscal root menisci injury menisciTibiaArthroplasty Replacement KneeFibrous jointOrthodontics030222 orthopedicsSuturesTibiabusiness.industrySuture TechniquesSignificant differenceStiffnessMeniscal suture030229 sport sciencesGeneral MedicineBiomechanical Phenomenamedicine.anatomical_structureOrthopedic surgerySurgerymedicine.symptombusinessArchives of Orthopaedic and Trauma Surgery
researchProduct

Ureteral injury during left colectomy for cancer: Laparoscopic management. A case report

2020

Abstract Introduction Iatrogenic ureteral lesions may occur after any abdominal and pelvic surgery. They are severe and can affect renal function and even vital prognosis. This study aimed to determine the clinical aspects and the therapeutic approaches of a lower third injury of the ureter during a laparoscopic left colectomy. Presentation of case An 81 year-old-man with left-sided colon cancer underwent laparoscopic left colectomy. During surgery there was a continuous full-thickness solution of the left ureter for which an end-to-end ureteral anastomosis was performed. In the postoperative period the patient underwent multiple urological and radiological interventional procedures due to …

medicine.medical_specialtymedicine.medical_treatmentIschemiaCase ReportAnastomosisurologic and male genital diseases03 medical and health sciences0302 clinical medicineUreterUreteral lesionmedicineLaparoscopyGynecological surgerymedicine.diagnostic_testbusiness.industryUretero-ureteral anastomosisStentmedicine.diseaseSurgeryIntracorporeal laparoscopic suturesmedicine.anatomical_structure030220 oncology & carcinogenesisLaparoscopic left colectomyIatrogenic ureteral lesion030211 gastroenterology & hepatologySurgeryPresentation (obstetrics)businessLigationInternational Journal of Surgery Case Reports
researchProduct

Use of the STAT (Sutureless Telescoping Anastomosis Technique) to facilitate supraaortic revascularization: Mid-term Results

2016

sutureleSTATSTAT; telescopinng; sutureless; anastomosisanastomosisSettore MED/22 - Chirurgia Vascolaretelescopinng
researchProduct